[Header]
Manifest Name	ImmuneResponse
Manifest Version	2.0
Build ID	hg19
Gene Model ID	RefSeq_Ensembl75
[Targets]
Target ID	Target Type	Gene	Transcript ID	Exon	Chromosome	Position	Alignment	Strand	Full Amplicon Sequence	Target Start	Target Length	Target Number
T00001	GeneExpression	PTPRCAP	ENST00000326294	1,2	chr11	67203742	84M1266N80M	Minus	CAGACGAGCACTGAGCTCACTTCTCGCTCGACACAGCCAGAGCTGGAGGTGGGTGCCCGGCACGGAGGGGCCTGCGGACCAATGGCTCTGCCCTGCACCTTAGGGCTCGGGATGCTGCTGGCCCTGCCAGGGGCCTTGGGCTCGGGTGGCAGCGCGGAGGACAG	16	134	1
T00002	GeneExpression	CTAG2	NM_172377	2,3	chrX	153880461	77M229N81M	Minus	TCCCGGGATGCCGCACCTCTCCCCCGACCAGGGGCGGTTCTGAAGGACTTCACCGTGTCCGGCAACCTACTGTTTATCCGACTGACTGCTGCAGACCACCGCCAACTGCAGCTCTCCATCAGCTCCTGTCTCCAGCAGCTTTCCCTGTTGATGTGGAT	16	128	1
T00003	GeneExpression		NM_020994		chrX	153880461	387M	Minus	TCCCGGGATGCCGCACCTCTCCCCCGACCAGGGGCGGTTCTGAAGGACTTCACCGTGTCCGGCAACCTACTGTTTATGTCAGTTCGGGACCAGGACAGGGAAGGCGCTGGGCGGATGAGGGTGGTGGGTTGGGGGCTGGGATCCGCCTCCCCGGAGGGGCAGAAAGCTAGAGATCTCAGAACACCCAAACACAAGGTCTCAGAACAGAGACCTGGTACACCAGGCCCGCCGCCACCCGAGGGAGCCCAGGGAGATGGGTGCAGAGGTGTCGCCTTTAATGTGATGTTCTCTGCCCCTCACATTTAGCCGACTGACTGCTGCAGACCACCGCCAACTGCAGCTCTCCATCAGCTCCTGTCTCCAGCAGCTTTCCCTGTTGATGTGGAT	16	357	2
T00004	GeneExpression	CX3CR1	ENST00000399220	1,2	chr3	39307943	62M13435N67M	Minus	GTCTGAGCAGGACAGGGTGGCTGACTGGCAGATCCAGAGGTTCCCTTGGCAGTCCACGCCAGGCCTTCACCATGGATCAGTTCCCTGAATCAGTGACAGAAAACTTTGAGTACGATGATTTGGCTGAGG	16	99	1
T00005	GeneExpression	CX3CR1	ENST00000435290	1,2	chr3	39307943	60M13730N67M	Minus	GACTGTGCTGTGCTTTGCTGACTGCAGGGCCTGCTCCCTGCCCCCCACCTCCAGGTTGGGGCCTTCACCATGGATCAGTTCCCTGAATCAGTGACAGAAAACTTTGAGTACGATGATTTGGCTGAGG	16	97	1
T00006	GeneExpression	CX3CR1	ENST00000541347	1,2	chr3	39307934	40M14524N76M	Minus	CAGAGCACCCGCTGTCCTCGGAACACCACAGCGACTAGAGGCCTTCACCATGGATCAGTTCCCTGAATCAGTGACAGAAAACTTTGAGTACGATGATTTGGCTGAGGCCTGTTATA	16	86	1
T00007	GeneExpression	FAS	NM_000043	2,3	chr10	90762867	85M4505N48M	Plus	AGGAAGACTGTTACTACAGTTGAGACTCAGAACTTGGAAGGCCTGCATCATGATGGCCAATTCTGCCATAAGCCCTGTCCTCCAGGTGAAAGGAAAGCTAGGGACTGCACAGTCAATGGGGATGAACCAGACT	16	103	1
T00008	GeneExpression	ARG1	NM_000045	2,3	chr6	131897825	51M2375N84M	Plus	GCCCTACAGTATTGAGAAAGGCTGGTCTGCTTGAGAAACTTAAAGAACAAGAGTGTGATGTGAAGGATTATGGGGACCTGCCCTTTGCTGACATCCCTAATGACAGTCCCTTTCAAATTGTGAAGAATCCAAGGT	16	105	1
T00009	GeneExpression		NM_001244438		chr6	131897825	51M2351N108M	Plus	GCCCTACAGTATTGAGAAAGGCTGGTCTGCTTGAGAAACTTAAAGAACAAGTAACTCAAAACTTTTTAATTTTAGAGTGTGATGTGAAGGATTATGGGGACCTGCCCTTTGCTGACATCCCTAATGACAGTCCCTTTCAAATTGTGAAGAATCCAAGGT	16	129	2
T00010	GeneExpression	BRCA2	NM_000059	26,27	chr13	32971108	74M1117N62M	Plus	CCACCCCAACTAAAGACTGTACTTCAGGGCCGTACACTGCTCAAATCATTCCTGGTACAGGAAACAAGCTTCTGATGTCTTCTCCTAATTGTGAGATATATTATCAAAGTCCTTTATCACTTTGTATGGCCAAAAG	16	106	1
T00011	GeneExpression	CD3G	NM_000073	6,7	chr11	118223156	47M631N85M	Plus	TTCAAGGAAACCAGTTGAGGAGGAATTGAACTCAGGACTCAGAGTAGTCCAGGTGTTCTCCTCCTATTCAGTTCCCAGAATCAAAGCAATGCATTTTGGAAAGCTCCTAGCAGAGAGACTTTCAGCCCTAAA	16	102	1
T00012	GeneExpression	CD40LG	NM_000074	4,5	chrX	135738560	18M2620N113M	Plus	GCAGTAAAACAACATCTGTGTTACAGTGGGCTGAAAAAGGATACTACACCATGAGCAACAACTTGGTAACCCTGGAAAATGGGAAACAGCTGACCGTTAAAAGACAAGGACTCTATTATATCTATGCCCAA	16	101	1
T00013	GeneExpression	CDKN2A	NM_000077	2,3	chr9	21968161	83M2659N81M	Minus	TGTCGCACGGTACCTGCGCGCGGCTGCGGGGGGCACCAGAGGCAGTAACCATGCCCGCATAGATGCCGCGGAAGGTCCCTCAGACATCCCCGATTGAAAGAACCAGAGAGGCTCTGAGAAACCTCGGGAAACTTAGATCATCAGTCACCGAAGGTCCTACAGGG	16	134	1
T00014	GeneExpression		NM_001195132		chr9	21968161	83M2130N197M332N81M	Minus	TGTCGCACGGTACCTGCGCGCGGCTGCGGGGGGCACCAGAGGCAGTAACCATGCCCGCATAGATGCCGCGGAAGGTCCCTCAGAAATGATCGGAAACCATTTGTGGGTTTGTAGAAGCAGGCATGCGTAGGGAAGCTACGGGATTCCGCCGAGGAGCGCCAGAGCCTGAGGCGCCCTTTGGTTATCGCAAGCTGGCTGGCTCACTCCGCACCAGGTGCAAAAGATGCCTGGGGATGCGGGAAGGGAAAGGCCACATCTTCACGCCTTCGCGCCTGGCATTACATCCCCGATTGAAAGAACCAGAGAGGCTCTGAGAAACCTCGGGAAACTTAGATCATCAGTCACCGAAGGTCCTACAGGG	16	331	2
T00015	GeneExpression	GUSB	NM_000181	10,11	chr7	65429343	33M3272N103M	Minus	TATGGAGCAGAAACGATTGCAGGGTTTCACCAGGATCCACCTCTGATGTTCACTGAAGAGTACCAGAAAAGTCTGCTAGAGCAGTACCATCTGGGTCTGGATCAAAAACGCAGAAAATACGTGGTTGGAGAGCTCA	16	106	1
T00016	GeneExpression	HMBS	NM_000190	10,11	chr11	118962846	28M240N111M	Plus	TGAGGAATGCATGTATGCTGTGGGCCAGGGGGCCTTGGGCGTGGAAGTGCGAGCCAAGGACCAGGACATCTTGGATCTGGTGGGTGTGCTGCACGATCCCGAGACTCTGCTTCGCTGCATCGCTGAAAGGGCCTTCCTG	16	109	1
T00017	GeneExpression		ENST00000546226		chr11	118962846	379M	Plus	TGAGGAATGCATGTATGCTGTGGGCCAGGTACACTTGACCAGGGAAGCCACATGGTGACATATGCCTTCCCTTTGTTCTCAACCAAGAAGCTTGTCTCACAACCTTCTGCATCTGCTTCCCCAGAATAGCATTCTCAGGGAGGGGCAGACCTTGGGATGCTACCGGTCCAAAAGGCGCTGGGGAGCAAGTAGATAGAGGTGGTCCCATGCTTTGCGCCATTGGTTGGGGAAAGATCAGGCCTGATGTCCTAGGATGTTTTTCCATCAGGGGGCCTTGGGCGTGGAAGTGCGAGCCAAGGACCAGGACATCTTGGATCTGGTGGGTGTGCTGCACGATCCCGAGACTCTGCTTCGCTGCATCGCTGAAAGGGCCTTCCTG	16	349	2
T00018	GeneExpression	ICAM1	NM_000201	2,3	chr19	10385644	61M8452N76M	Plus	ATGTGCTATTCAAACTGCCCTGATGGGCAGTCAACAGCTAAAACCTTCCTCACCGTGTACTGGACTCCAGAACGGGTGGAACTGGCACCCCTCCCCTCTTGGCAGCCAGTGGGCAAGAACCTTACCCTACGCTGCCA	16	107	1
T00019	GeneExpression	IL2RG	NM_000206	6,7	chrX	70328140	78M252N57M	Minus	ATTGGAAGCCGTGGTTATCTCTGTTGGCTCCATGGGATTGATTATCAGCCTTCTCTGTGTGTATTTCTGGCTGGAACGGACGATGCCCCGAATTCCCACCCTGAAGAACCTAGAGGATCTTGTTACTGAATACCA	16	105	1
T00020	GeneExpression		ENST00000512747		chrX	70328140	387M	Minus	ATTGGAAGCCGTGGTTATCTCTGTTGGCTCCATGGGATTGATTATCAGCCTTCTCTGTGTGTATTTCTGGCTGGAACGGTGAGATTTGGAGAAGCCCAGAAAAATGAGGGGAACGGTAGCTGACAATAGCAGAGGAGGGTTTTGCAGGGTCTTTAGGAGTAAAGGATGAGACAGTAAGTAATGAGAGATTACCCAAGAGGGTTTGGTGATGGAAGGAAGCCACAGGCACAGAGAACACAGAATCACTTTATTTCATATGGGACAACTGGGAGAAGGGTGATAAAAAAGCTTTAACCTATGTGCTCCTGCTCCCTCTTTCTCCCCTGTCAGGACGATGCCCCGAATTCCCACCCTGAAGAACCTAGAGGATCTTGTTACTGAATACCA	16	357	2
T00021	GeneExpression	ITGB2	NM_000211	11,12	chr21	46310120	119M1586N18M	Minus	GGCTTCACGGACATAGTGACCGTGCAGGTTCTTCCCCAGTGTGAGTGCCGGTGCCGGGACCAGAGCAGAGACCGCAGCCTCTGCCATGGCAAGGGCTTCTTGGAGTGCGGCATCTGCAGGTGTGACACTGGCTACAT	16	107	1
T00022	GeneExpression	LYZ	NM_000239	1,2	chr12	69742238	87M1563N46M	Plus	AGGGCAAGGTCTTTGAAAGGTGTGAGTTGGCCAGAACTCTGAAAAGATTGGGAATGGATGGCTACAGGGGAATCAGCCTAGCAAACTGGATGTGTTTGGCCAAATGGGAGAGTGGTTACAACACACGAGCTAC	16	103	1
T00023	GeneExpression	CIITA	NM_000246	2,3	chr16	10989232	54M240N80M	Plus	ACTTCTATGACCAGATGGACCTGGCTGGAGAAGAAGAGATTGAGCTCTACTCAGAACCCGACACAGACACCATCAACTGCGACCAGTTCAGCAGGCTGTTGTGTGACATGGAAGGTGATGAAGAGACCAGGGAG	16	104	1
T00024	GeneExpression	MPO	NM_000250	8,9	chr17	56350938	46M1872N93M	Minus	GAGGCTCTACCAGGAAGCCCGGAAGATCGTGGGGGCCATGGTCCAGATCATCACTTACCGGGACTACCTGCCCCTGGTGCTGGGGCCAACGGCCATGAGGAAGTACCTGCCCACGTACCGTTCCTACAATGACTCAGTG	16	109	1
T00025	GeneExpression	NCF1	NM_000265	5,6	chr7	74195154	28M2100N111M	Plus	CCCAAAGATGGCAAGAGTACCGCGACAGACATCACCGGCCCCATCATCCTGCAGACGTACCGCGCCATTGCCAACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	109	1
T00026	None		NR_003186		chr7	72641472	28M2101N111M	Plus	CCCAAAGATGGCAAGAGTACCGCGACAGACATCACCGGCCCCATCATCCTGCAGACGTACCGCGCCATTGCCAACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	109	-1
T00027	None		NR_003187		chr7	74578714	28M2104N111M	Minus	CCCAAAGATGGCAAGAGTACCGCGACAGACATCACCGGCCCCATCATCCTGCAGACGTACCGCGCCATTGCCGACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	109	-2
T00028	None		ENST00000435988		chr7	72641472	42M2101N97M	Plus	CCCAAAGATGGCAAGAGTACCGCGACAGGTGAGAGGACGGGGATCATCCTGCAGACGTACCGCGCCATTGCCAACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	109	-3
T00029	GeneExpression	PTEN	NM_000314	8,9	chr10	89720776	100M4168N36M	Plus	AGATAATGACAAGGAATATCTAGTACTTACTTTAACAAAAAATGATCTTGACAAAGCAAATAAAGACAAAGCCAACCGATACTTTTCTCCAAATTTTAAGGTGAAGCTGTACTTCACAAAAACAGTAGAGGAGCCG	16	106	1
T00030	None		NR_023917		chr9	33675588	136M	Minus	AGATAATGACAAGGAGTATCTAGTACTTACTTTAACAAAAAATGATCTTGACAAAGCAAATAAAGACAAAGCCAACCGATACTTTTCTCCAAATTTTAAGGTGAAGCTGTACTTCACAAAAACAGTAGAGGAGCCG	16	106	-1
T00031	GeneExpression	RB1	NM_000321	22,23	chr13	49039200	48M93N84M	Plus	TTCATGCAGAGACTGAAAACAAATATTTTGCAGTATGCTTCCACCAGGCCCCCTACCTTGTCACCAATACCTCACATTCCTCGAAGCCCTTACAAGTTTCCTAGTTCACCCTTACGGATTCCTGGAGGGAAC	16	102	1
T00032	GeneExpression	CSF2RB	NM_000395	8,9	chr22	37326825	48M1934N87M	Plus	CTGTTCAGCCAAGGAGGGCAGAGAAACACATAAAGAGCTCAGTGAACATCCAGATGGCCCCTCCATCCCTCAACGTGACCAAGGATGGAGACAGCTACAGCCTGCGCTGGGAAACAATGAAAATGCGATACGAAC	16	105	1
T00033	GeneExpression	CYBB	NM_000397	11,12	chrX	37665671	116M3033N22M	Plus	ATGCCTTTGAGTGGTTTGCAGATCTGCTGCAACTGCTGGAGAGCCAGATGCAGGAAAGGAACAATGCCGGCTTCCTCAGCTACAACATCTACCTCACTGGCTGGGATGAGTCTCAGGCCAATCACTTTGCTGTGCACC	16	108	1
T00034	GeneExpression	EGR2	NM_000399	1,2	chr10	64574161	68M1392N68M	Minus	GTCGGTGACCATCTTTCCCAATGCCGAACTGGGAGGCCCCTTTGACCAGATGAACGGAGTGGCCGGAGATGGCATGATCAACATTGACATGACTGGAGAGAAGAGGTCGTTGGATCTCCCATATCCCAGCAGCTTT	16	106	1
T00035	GeneExpression	G6PD	NM_000402	8,9	chrX	153761237	34M447N107M	Minus	CTCCACCAACTCAGATGACGTCCGTGATGAGAAGGTCAAGGTGTTGAAATGCATCTCAGAGGTGCAGGCCAACAATGTGGTCCTGGGCCAGTACGTGGGGAACCCCGATGGAGAGGGCGAGGCCACCAAAGGGTACCTGGA	16	111	1
T00036	GeneExpression	IL2RA	NM_000417	1,2	chr10	6067919	59M36062N70M	Minus	TTCATACCTGCTGATGTGGGGACTGCTCACGTTCATCATGGTGCCTGGCTGCCAGGCAGAGCTCTGTGACGATGACCCGCCAGAGATCCCACACGCCACATTCAAAGCCATGGCCTACAAGGAAGGAAC	16	99	1
T00037	GeneExpression	KRT5	NM_000424	4,5	chr12	52911449	43M142N90M	Minus	ACTGATGGATGAGATTAACTTCATGAAGATGTTCTTTGATGCGGAGCTGTCCCAGATGCAGACGCATGTCTCTGACACCTCAGTGGTCCTCTCCATGGACAACAACCGCAACCTGGACCTGGATAGCATCATC	16	103	1
T00038	GeneExpression	NOTCH3	NM_000435	4,5	chr19	15302572	33M92N107M	Minus	GCGACCTCACTTACGACTGTGCCTGTCTTCCTGGGTTTGAGGGTCAGAATTGTGAAGTGAACGTGGACGACTGTCCAGGACACCGATGTCTCAATGGGGGGACATGCGTGGATGGCGTCAACACCTATAACTGCCAGTGC	16	110	1
T00039	GeneExpression	TWIST1	NM_000474	1,2	chr7	19155709	89M539N46M	Minus	CGGTCTGGAGGATGGAGGGGGCCTGGTCCATGTCCGCGTCCCACTAGCAGGCGGAGCCCCCCACCCCCTCAGCAGGGCCGGAGACCTAGATGTCATTGTTTCCAGAGAAGGAGAAAATGGACAGTCTAGAGACTC	16	105	1
T00040	GeneExpression	C1QB	NM_000491	1,2	chr1	22979777	20M6136N99M	Plus	ACAGGACACCAGCTTCCCAGGAGGCGTCTGACACAGTATGATGATGAAGATCCCATGGGGCAGCATCCCAGTACTGATGTTGCTCCTGCTCCTGGGCCTAATCGATATCTCCCAGGCCC	16	89	1
T00041	GeneExpression		ENST00000432749		chr1	22979777	20M704N153M5279N99M	Plus	ACAGGACACCAGCTTCCCAGCCCTGTCAGGTTGAAATCAGCATTGCCAAGAGGCTCAGAGAGGTTAAGGCACTTGCCTGAGGTTATGCAGCCGGTAGCAGATGGGGCTTTAAAGTCAAGTGGGCCTGACTCCATGTTGCGGAAAGGGACTGCTGGACCGAAGGAGATGGAAAGGAGGCGTCTGACACAGTATGATGATGAAGATCCCATGGGGCAGCATCCCAGTACTGATGTTGCTCCTGCTCCTGGGCCTAATCGATATCTCCCAGGCCC	16	242	2
T00042	GeneExpression	FCGR1A	NM_000566	4,5	chr1	149760096	78M1436N58M	Plus	GTCACAATGGCACCTACCATTGCTCAGGCATGGGAAAGCATCGCTACACATCAGCAGGAATATCTGTCACTGTGAAAGAGCTATTTCCAGCTCCAGTGCTGAATGCATCTGTGACATCCCCACTCCTGGAGGGGAA	16	106	1
T00043	None		NR_045213		chr1	120928558	81M1423N58M	Minus	GTCACAATGGCACCTACCATTGCTCAGGCATGGGAAAGCATCGCTACACATCAGCAGGAATATCACAATACACTGTGAAAGAGCTATTTCCAGCTCCAGTGCTGAATGCATCTGTGACATCCCCACTCCTGGAGGGGAA	16	109	-1
T00044	GeneExpression	FCGR3A	NM_000569	3,4	chr1	161514663	52M3462N86M	Minus	CAGACAAACCTCTCCACCCTCAGTGACCCGGTGCAGCTAGAAGTCCATATCGGCTGGCTGTTGCTCCAGGCCCCTCGGTGGGTGTTCAAGGAGGAAGACCCTATTCACCTGAGGTGTCACAGCTGGAAGAACACTGCT	16	108	1
T00045	None		NM_000570		chr1	161596107	52M3375N86M	Minus	CAGACAAACCTCTCCACCCTCAGTGACCCGGTGCAGCTAGAAGTCCATATCGGCTGGCTGTTGCTCCAGGCCCCTCGGTGGGTGTTCAAGGAGGAAGACCCTATTCACCTGAGGTGTCACAGCTGGAAGAACACTGCT	16	108	-1
T00046	GeneExpression	FCGR3B	NM_000570	5,6	chr1	161594392	95M1505N38M	Minus	AGCCACACTCAAAGATAGCGGCTCCTACTTCTGCAGGGGGCTTGTTGGGAGTAAAAATGTGTCTTCAGAGACTGTGAACATCACCATCACTCAAGGTTTGGCAGTGTCAACCATCTCATCATTCTCTCCACCT	16	103	1
T00047	None		NM_000569		chr1	161512952	95M1501N38M	Minus	AGCCACACTCAAAGACAGCGGCTCCTACTTCTGCAGGGGGCTTTTTGGGAGTAAAAATGTGTCTTCAGAGACTGTGAACATCACCATCACTCAAGGTTTGGCAGTGTCAACCATCTCATCATTCTCTCCACCT	16	103	-1
T00048	GeneExpression	IL10	NM_000572	4,5	chr1	206941964	28M1100N110M	Minus	GGAGCAGGTGAAGAATGCCTTTAATAAGCTCCAAGAGAAAGGCATCTACAAAGCCATGAGTGAGTTTGACATCTTCATCAACTACATAGAAGCCTACATGACAATGAAGATACGAAACTGAGACATCAGGGTGGCGAC	16	108	1
T00049	GeneExpression	IL1A	NM_000575	5,6	chr2	113535578	23M1384N111M	Minus	ATTACATAATCTGGATGAAGCAGTGAAATTTGACATGGGTGCTTATAAGTCATCAAAGGATGATGCTAAAATTACCGTGATTCTAAGAATCTCAAAAACTCAATTGTATGTGACTGCCCAAGATGAAGACCAAC	16	104	1
T00050	GeneExpression	IL1B	NM_000576	6,7	chr2	113588054	41M718N97M	Minus	CCTGCGTGTTGAAAGATGATAAGCCCACTCTACAGCTGGAGAGTGTAGATCCCAAAAATTACCCAAAGAAGAAGATGGAAAAGCGATTTGTCTTCAACAAGATAGAAATCAATAACAAGCTGGAATTTGAGTCTGCCC	16	108	1
T00051	GeneExpression	IL8	NM_000584	1,2	chr4	74606404	36M819N100M	Plus	TGGCAGCCTTCCTGATTTCTGCAGCTCTGTGTGAAGGTGCAGTTTTGCCAAGGAGTGCTAAAGAACTTAGATGTCAGTGCATAAAGACATACTCCAAACCTTTCCACCCCAAATTTATCAAAGAACTGAGAGTGAT	16	106	1
T00052	GeneExpression	IL15	NM_000585	1,2	chr4	142557782	120M19437N17M	Plus	TCCCAGCTGACTCGCTCACTGCCTTCGAAGTCCGGCGCCCCCCGGGAGGGAACTGGGTGGCCGCACCCTCCCGGCTGCGGTGGCTGTCGCCCCCCACCCTGCAGCCAGGACTCGATGGAGAATCCATTCCAATATAT	16	107	1
T00053	GeneExpression	IL2	NM_000586	3,4	chr4	123372958	56M1847N60M	Minus	ACTTAAGACCCAGGGACTTAATCAGCAATATCAACGTAATAGTTCTGGAACTAAAGGGATCTGAAACAACATTCATGTGTGAATATGCTGATGAGACAGCAACCATTGTAGAATTT	16	86	1
T00054	GeneExpression	IL4	NM_000589	3,4	chr5	132015522	61M2595N67M	Plus	CAAGCAGCTGATCCGATTCCTGAAACGGCTCGACAGGAACCTCTGGGGCCTGGCGGGCTTGAATTCCTGTCCTGTGAAGGAAGCCAACCAGAGTACGTTGGAAAACTTCTTGGAAAGGCTAAAGACGA	16	98	1
T00055	GeneExpression	CD14	NM_000591	1,2	chr5	140012498	69M88N68M	Minus	TAGGAAAGAAGCTAAAGCACTTCCAGAGCCTGTCCGGAGCTCAGAGGTTCGGAAGACTTATCGACCATGGAGCGCGCGTCCTGCTTGTTGCTGCTGCTGCTGCCGCTGGTGCACGTCTCTGCGACCACGCCAGAACC	16	107	1
T00056	GeneExpression	TAP1	NM_000593	5,6	chr6	32816789	29M1201N107M	Minus	CCTATGCAGTCAACTCCTGGACCACTAGTATTTCAGGTATGCTGCTGAAAGTGGGAATCCTCTACATTGGTGGGCAGCTGGTGACCAGTGGGGCTGTAAGCAGTGGGAACCTTGTCACATTTGTTCTCTACCAGAT	16	106	1
T00057	GeneExpression	TNF	NM_000594	3,4	chr6	31544571	21M301N115M	Plus	AGCCTGTAGCCCATGTTGTAGCAAACCCTCAAGCTGAGGGGCAGCTCCAGTGGCTGAACCGCCGGGCCAATGCCCTCCTGGCCAATGGCGTGGAGCTGAGAGATAACCAGCTGGTGGTGCCATCAGAGGGCCTGTA	16	106	1
T00058	GeneExpression	IL6	NM_000600	4,5	chr7	22769198	82M1745N54M	Plus	GAACAGATTTGAGAGTAGTGAGGAACAAGCCAGAGCTGTGCAGATGAGTACAAAAGTCCTGATCCAGTTCCTGCAGAAAAAGGCAAAGAATCTAGATGCAATAACCACCCCTGACCCAACCACAAATGCCAGCCTG	16	106	1
T00059	GeneExpression	HGF	NM_000601	10,11	chr7	81346585	37M3379N97M	Minus	GTTCAATGTGGGACAAGAACATGGAAGACTTACATCGTCATATCTTCTGGGAACCAGATGCAAGTAAGCTGAATGAGAATTACTGCCGAAATCCAGATGATGATGCTCATGGACCCTGGTGCTACACGGGAAAT	16	104	1
T00060	GeneExpression	CD44	NM_000610	5,6	chr11	35211511	102M6680N37M	Plus	CTTCAGGAGGTTACATCTTTTACACCTTTTCTACTGTACACCCCATCCCAGACGAAGACAGTCCCTGGATCACCGACAGCACAGACAGAATCCCTGCTACCACTTTGATGAGCACTAGTGCTACAGCAACTGAGACAGC	16	109	1
T00061	GeneExpression	CD4	NM_000616	1,2	chr12	6898769	60M10409N79M	Plus	AGTCCTCACACAGATACGCCTGTTTGAGAAGCAGCGGGCAAGAAAGACGCAAGCCCAGAGGCCCTGCCATTTCTGTGGGCTCAGGTCCCTACTGGCTCAGGCCCCTGCCTCCCTCGGCAAGGCCACAATGAACCGGGGA	16	109	1
T00062	GeneExpression		ENST00000536610		chr12	6898769	60M9875N86M448N79M	Plus	AGTCCTCACACAGATACGCCTGTTTGAGAAGCAGCGGGCAAGAAAGACGCAAGCCCAGAGTGGTGCAATCTTGGCTCACTGCAACCTCCTCCTCCCTGGTTCAAGTGATTCTCCTGCCTCAGCTTCCTAAGCACCTGAGACTACAGGCCCTGCCATTTCTGTGGGCTCAGGTCCCTACTGGCTCAGGCCCCTGCCTCCCTCGGCAAGGCCACAATGAACCGGGGA	16	195	2
T00063	GeneExpression		ENST00000535466		chr12	6898769	60M9217N195M997N79M	Plus	AGTCCTCACACAGATACGCCTGTTTGAGAAGCAGCGGGCAAGAAAGACGCAAGCCCAGAGAAAATCCTCTGCTGGCTCTCTAGTGCCCAGGATCCAGTCCCAGCATCTCAGCACGGCCTTCAAGCATTTCCACGTCCTGGCCTGGCTCCATGGTCTCCCCGCCAATTTGCCACCTTCTCCATGCATCCTTTTCTGATCCCCTCCTCACTCATCCCAGCAAAGAACCCCCTCCTGGCCTGAGCATAGCATTTCGTGGCCCTGCCATTTCTGTGGGCTCAGGTCCCTACTGGCTCAGGCCCCTGCCTCCCTCGGCAAGGCCACAATGAACCGGGGA	16	304	3
T00064	GeneExpression		ENST00000536590		chr12	6898769	60M9662N40M707N79M	Plus	AGTCCTCACACAGATACGCCTGTTTGAGAAGCAGCGGGCAAGAAAGACGCAAGCCCAGAGCTGCCTAAGCTTTAGCCAGCATGTGCCTTTTGGTTGACAGGCCCTGCCATTTCTGTGGGCTCAGGTCCCTACTGGCTCAGGCCCCTGCCTCCCTCGGCAAGGCCACAATGAACCGGGGA	16	149	4
T00065	GeneExpression		ENST00000539492		chr12	6898769	60M9217N195M463N86M448N79M	Plus	AGTCCTCACACAGATACGCCTGTTTGAGAAGCAGCGGGCAAGAAAGACGCAAGCCCAGAGAAAATCCTCTGCTGGCTCTCTAGTGCCCAGGATCCAGTCCCAGCATCTCAGCACGGCCTTCAAGCATTTCCACGTCCTGGCCTGGCTCCATGGTCTCCCCGCCAATTTGCCACCTTCTCCATGCATCCTTTTCTGATCCCCTCCTCACTCATCCCAGCAAAGAACCCCCTCCTGGCCTGAGCATAGCATTTCGTGTGGTGCAATCTTGGCTCACTGCAACCTCCTCCTCCCTGGTTCAAGTGATTCTCCTGCCTCAGCTTCCTAAGCACCTGAGACTACAGGCCCTGCCATTTCTGTGGGCTCAGGTCCCTACTGGCTCAGGCCCCTGCCTCCCTCGGCAAGGCCACAATGAACCGGGGA	16	390	5
T00066	GeneExpression	IFNG	NM_000619	3,4	chr12	68549245	108M2425N23M	Minus	CAGAGCATCCAAAAGAGTGTGGAGACCATCAAGGAAGACATGAATGTCAAGTTTTTCAATAGCAACAAAAAGAAACGAGATGACTTCGAAAAGCTGACTAATTATTCGGTAACTGACTTGAATGTCCAACG	16	101	1
T00067	GeneExpression	NOS2	NM_000625	1,2	chr17	26125890	116M1456N19M	Minus	GGCCACCTTTGATGAGGGGACTGGGCAGTTCTAGACAGTCCCGAAGTTCTCAAGGCACAGGTCTCTTCCTGGTTTGACTGTCCTTACCCCGGGGAGGCAGTGCAGCCAGCTGCAAGCCCCACAGTGAAGAACATC	16	105	1
T00068	GeneExpression	BCL2	NM_000633	2,3	chr18	60795912	54M189322N81M	Minus	ACTGAGTACCTGAACCGGCACCTGCACACCTGGATCCAGGATAACGGAGGCTGGGATGCCTTTGTGGAACTGTACGGCCCCAGCATGCGGCCTCTGTTTGATTTCTCCTGGCTGTCTCTGAAGACTCTGCTCAGT	16	105	1
T00069	GeneExpression	FASLG	NM_000639	1,2	chr1	172628586	104M545N31M	Plus	GTCTCCTTGTGATGTTTTTCATGGTTCTGGTTGCCTTGGTAGGATTGGGCCTGGGGATGTTTCAGCTCTTCCACCTACAGAAGGAGCTGGCAGAACTCCGAGAGTCTACCAGCCAGATGCACACAGCATCATCTT	16	105	1
T00070	GeneExpression	SELL	NM_000655	1,2	chr1	169679606	84M978N53M	Minus	TGGGCAAGGACCTGAGACCCTTGTGCTAAGTCAAGAGGCTCAATGGGCTGCAGAAGAACTAGAGAAGGACCAAGCAAAGCCATGATATTTCCATGGAAATGTCAGAGCACCCAGAGGGACTTATGGAACATCTTCAA	16	107	1
T00071	GeneExpression	TGFB1	NM_000660	2,3	chr19	41850679	46M3430N91M	Minus	GCTGAGGCTCAAGTTAAAAGTGGAGCAGCACGTGGAGCTGTACCAGAAATACAGCAACAATTCCTGGCGATACCTCAGCAACCGGCTGCTGGCACCCAGCGACTCGCCAGAGTGGTTATCTTTTGATGTCACCGGAG	16	107	1
T00072	GeneExpression	ADORA2A	NM_000675	2,3	chr22	24829669	36M6846N97M	Plus	CATTGACCGCTACATTGCCATCCGCATCCCGCTCCGGTACAATGGCTTGGTGACCGGCACGAGGGCTAAGGGCATCATTGCCATCTGCTGGGTGCTGTCGTTTGCCATCGGCCTGACTCCCATGCTAGGTTGG	16	103	1
T00073	GeneExpression	CA4	NM_000717	4,5	chr17	58234830	104M117N37M	Plus	GACTGCCTGCCCCATACCAGGCCAAACAGTTGCACCTGCACTGGTCCGACTTGCCATATAAGGGCTCGGAGCACAGCCTCGATGGGGAGCACTTTGCCATGGAGATGCACATAGTACATGAGAAAGAGAAGGGGACATCGA	16	111	1
T00074	GeneExpression	CD3D	NM_000732	2,3	chr11	118210515	27M468N107M	Minus	AATCTACCGTGCAAGTTCATTATCGAATGTGCCAGAGCTGTGTGGAGCTGGATCCAGCCACCGTGGCTGGCATCATTGTCACTGATGTCATTGCCACTCTGCTCCTTGCTTTGGGAGTCTTCTGCTTTGCTGGA	16	104	1
T00075	GeneExpression	CD3E	NM_000733	7,8	chr11	118184475	115M573N19M	Plus	GTGGACATCTGCATCACTGGGGGCTTGCTGCTGCTGGTTTACTACTGGAGCAAGAATAGAAAGGCCAAGGCCAAGCCTGTGACACGAGGAGCGGGTGCTGGCGGCAGGCAAAGGGGACAAAACAAGGAGAGGCC	16	104	1
T00076	GeneExpression	IGF1R	NM_000875	5,6	chr15	99442767	84M9063N56M	Plus	GAAGATCCGCCATTCTCATGCCTTGGTCTCCTTGTCCTTCCTAAAAAACCTTCGCCTCATCCTAGGAGAGGAGCAGCTAGAAGGGAATTACTCCTTCTACGTCCTCGACAACCAGAACTTGCAGCAACTGTGGGACTGGG	16	110	1
T00077	GeneExpression	IL2RB	NM_000878	9,10	chr22	37524801	51M3535N88M	Minus	CCCTCGAAGTTCTTTTCCCAGCTGAGCTCAGAGCATGGAGGAGACGTCCAGAAGTGGCTCTCTTCGCCCTTCCCCTCATCGTCCTTCAGCCCTGGCGGCCTGGCACCTGAGATCTCGCCACTAGAAGTGCTGGAGAGGG	16	109	1
T00078	GeneExpression	IL7	NM_000880	1,2	chr8	79710388	82M6704N56M	Minus	TGACTATGGGCGGTGAGAGCTTGCTCCTGCTCCAGTTGCGGTCATCATGACTACGCCCGCCTCCCGCAGACCATGTTCCATGTTTCTTTTAGGTATATCTTTGGACTTCCTCCCCTGATCCTTGTTCTGTTGCCAGTA	16	108	1
T00079	GeneExpression	IL12A	NM_000882	6,7	chr3	159711528	104M1559N30M	Plus	ACCAGGTGGAGTTCAAGACCATGAATGCAAAGCTTCTGATGGATCCTAAGAGGCAGATCTTTCTAGATCAAAACATGCTGGCAGTTATTGATGAGCTGATGCAGGCCCTGAATTTCAACAGTGAGACTGTGCCA	16	104	1
T00080	GeneExpression	ITGAX	NM_000887	16,17	chr16	31382779	40M132N94M	Plus	CTTTACATTGACAAACGTTCTAAGAACCTGCTTGGGAGCCGTGACCTCCAAAGCTCTGTGACCTTGGACCTGGCCCTCGACCCTGGCCGCCTGAGTCCCCGTGCCACCTTCCAGGAAACAAAGAACCGGAGTCT	16	104	1
T00081	GeneExpression	ITGB7	NM_000889	15,16	chr12	53585329	49M222N92M	Minus	GGAATACAGTCGCTTTGAGAAGGAGCAGCAACAACTCAACTGGAAGCAGGACAGTAATCCTCTCTACAAAAGTGCCATCACGACCACCATCAATCCTCGCTTTCAAGAGGCAGACAGTCCCACTCTCTGAAGGAGGGAGGG	16	111	1
T00082	GeneExpression		ENST00000551319		chr12	53585329	49M127N187M	Minus	GGAATACAGTCGCTTTGAGAAGGAGCAGCAACAACTCAACTGGAAGCAGCTCCTAGGATTCGGCTCAAGGCTGGCCTCTTAGGTCTAGAAAGGGGACGAGGAATCCTGGGATTTTTGCTTATAATCTGCAACATCTTTCTCCAGGACAGTAATCCTCTCTACAAAAGTGCCATCACGACCACCATCAATCCTCGCTTTCAAGAGGCAGACAGTCCCACTCTCTGAAGGAGGGAGGG	16	206	2
T00083	GeneExpression	POLR2A	NM_000937	23,24	chr17	7414552	87M86N45M	Plus	AAGATGGATGATGATGTCTTCCTGCGCTGCATCGAGTCCAACATGCTGACAGATATGACCCTGCAGGGCATCGAGCAGATCAGCAAGGTGTACATGCACTTGCCACAGACAGACAACAAGAAGAAGATCATC	16	102	1
T00084	GeneExpression	PTGS2	NM_000963	9,10	chr1	186643839	82M486N56M	Minus	AGGCAGATGAAATACCAGTCTTTTAATGAGTACCGCAAACGCTTTATGCTGAAGCCCTATGAATCATTTGAAGAACTTACAGGAGAAAAGGAAATGTCTGCAGAGTTGGAAGCACTCTATGGTGACATCGATGCTGTG	16	108	1
T00085	GeneExpression	GATA3	NM_001002295	4,5	chr10	8106011	91M5334N48M	Plus	TGGCACGGGACACTACCTGTGCAACGCCTGCGGGCTCTATCACAAAATGAACGGACAGAACCGGCCCCTCATTAAGCCCAAGCGAAGGCTGTCTGCAGCCAGGAGAGCAGGGACGTCCTGTGCGAACTGTCAGACCACC	16	109	1
T00086	GeneExpression	TARP	NM_001003806	3,4	chr7	38299739	39M1940N93M	Minus	CAATGGATCCCAAAGACAATTGTTCAAAAGATGCAAATGATACACTACTGCTGCAGCTCACAAACACCTCTGCATATTACATGTACCTCCTCCTGCTCCTCAAGAGTGTGGTCTATTTTGCCATCATCACCT	16	102	1
T00087	None		ENST00000436911		chr7	38279675	39M2261N93M	Minus	CAATGGATCCCAAAGACAATTGGTCAAAAGATGCAAATGATACACTACTGCTGCAGCTCACAAACACCTCTGCATATTACACGTACCTCCTCCTGCTCCTCAAGAGTGTGGTCTATTTTGCCATCATCACCT	16	102	-1
T00088	GeneExpression	RPS6	NM_001010	2,3	chr9	19378853	72M568N64M	Minus	AAACTTCGTACTTTCTATGAGAAGCGTATGGCCACAGAAGTTGCTGCTGACGCTCTGGGTGAAGAATGGAAGGGTTATGTGGTCCGAATCAGTGGTGGGAACGACAAACAAGGTTTCCCCATGAAGCAGGGTGTCT	16	106	1
T00089	GeneExpression	MAGEA4	NM_001011548	1,2	chrX	151081373	69M10483N65M	Plus	GCTTCTGCGTCTGACTCGCAGCTTGAGACTGGCGGAGGGAAGCCCGCCCAGGCTCTATAAGGAGACAAGGTTCTGAGCAGACAGGCCAACCGGAGGACAGGATTCCCTGGAGGCCACAGAGGAGCACCAAGGAG	16	104	1
T00090	GeneExpression	AKT1	NM_001014431	2,3	chr14	105246458	44M12381N96M	Minus	GAGCGACGTGGCTATTGTGAAGGAGGGTTGGCTGCACAAACGAGGGGAGTACATCAAGACCTGGCGGCCACGCTACTTCCTCCTCAAGAATGATGGCACCTTCATTGGCTACAAGGAGCGGCCGCAGGATGTGGACCAAC	16	110	1
T00091	GeneExpression	CD276	NM_001024736	5,6	chr15	73996218	121M178N19M	Plus	CTGGCACAAGGCAATGCATCCCTGAGGCTGCAGCGCGTGCGTGTGGCGGACGAGGGCAGCTTCACCTGCTTCGTGAGCATCCGGGATTTCGGCAGCGCTGCCGTCAGCCTGCAGGTGGCCGCTCCCTACTCGAAGCCCAG	16	110	1
T00092	GeneExpression	ABCF1	NM_001025091	12,13	chr6	30551629	39M301N101M	Plus	GCATCCCTCCCAACATTGATGTGTTGCTGTGTGAGCAGGAGGTGGTAGCAGATGAGACACCAGCAGTCCAGGCTGTTCTTCGAGCTGACACCAAGCGATTGAAGCTGCTGGAAGAGGAGCGGCGGCTTCAGGGACAGCTG	16	110	1
T00093	GeneExpression	CD74	NM_001025159	6,7	chr5	149782777	41M1367N99M	Minus	GCACTCCTTGGAGCAAAAGCCCACTGACGCTCCACCGAAAGTACTGACCAAGTGCCAGGAAGAGGTCAGCCACATCCCTGCTGTCCACCCGGGTTCATTCAGGCCCAAGTGCGACGAGAACGGCAACTATCTGCCACTCC	16	110	1
T00094	GeneExpression	IFIT3	NM_001031683	1,2	chr10	91092295	90M6033N43M	Plus	TCTTCAGCATTTGCTTGGAATCAGTAAGCTAAAAACAAAATCAACCGGGACCCCAGCTTTTCAGAACTGCAGGGAAACAGCCATCATGAGTGAGGTCACCAAGAATTCCCTGGAGAAAATCCTTCCACAGCTG	16	103	1
T00095	GeneExpression	CD79B	NM_001039933	3,4	chr17	62007160	48M185N89M	Minus	ACACCTCGGAGGTCTACCAGGGCTGCGGCACAGAGCTGCGAGTCATGGGATTCAGCACCTTGGCACAGCTGAAGCAGAGGAACACGCTGAAGGATGGTATCATCATGATCCAGACGCTGCTGATCATCCTCTTCATC	16	107	1
T00096	GeneExpression	CD53	NM_001040033	1,2	chr1	111413833	49M1896N87M	Plus	AAGAAACATCCAAGGTGGTCTTGAAGGACACTGGGATCCTGTAACACAGCCCCGGATATCTGTGTTACCAGCCTTGTCTCGGCCACCTCAAGGATAATCACTAAATTCTGCCGAAAGGACTGAGGAACGGTGCCTG	16	106	1
T00097	GeneExpression	GAGE1	NM_001040663	2,3	chrX	49364783	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAACGTCA	16	117	1
T00098	GeneExpression	PVRL2	NM_001042724	5,6	chr19	45377676	60M7732N79M	Plus	TCTGCACAGTCACCAATGCCGTGGGCATGGGCCGCGCTGAGCAGGTCATCTTTGTCCGAGAGACCCCCAACACAGCAGGCGCAGGGGCCACAGGCGGCATCATCGGGGGCATCATCGCCGCCATCATTGCTACTGCTGT	16	109	1
T00099	GeneExpression	LCK	NM_001042771	1,2	chr1	32739785	43M98N91M	Plus	TCTGTGGCTGGTGAATGGGGATCCCAGGATCTCACAATCTCAGGGACCATGGGCTGTGGCTGCAGCTCACACCCGGAAGATGACTGGATGGAAAACATCGATGTGTGTGAGAACTGCCATTATCCCATAGTCCC	16	104	1
T00100	GeneExpression		ENST00000373562		chr1	32739785	43M77N112M	Plus	TCTGTGGCTGGTGAATGGGGATCCCAGGATCTCACAATCTCAGCCCCCTCTTCCATTCCCTCAGGGACCATGGGCTGTGGCTGCAGCTCACACCCGGAAGATGACTGGATGGAAAACATCGATGTGTGTGAGAACTGCCATTATCCCATAGTCCC	16	125	2
T00101	GeneExpression		ENST00000373557		chr1	32739785	232M	Plus	TCTGTGGCTGGTGAATGGGGATCCCAGGATCTCACAATCTCAGGTACTTTTGGAACTTTCCAGGGCAAGGCCCCATTATATCTGATGTTGGGGGAGCAGATCTTGGGGGAGCCCCTTCAGCCCCCTCTTCCATTCCCTCAGGGACCATGGGCTGTGGCTGCAGCTCACACCCGGAAGATGACTGGATGGAAAACATCGATGTGTGTGAGAACTGCCATTATCCCATAGTCCC	16	202	3
T00102	GeneExpression	TOP2A	NM_001067	21,22	chr17	38556869	87M186N47M	Minus	TGGTCCTGCAAAATCCCCAACTTTGATGTGCGTGAAATTGTAAATAACATCAGGCGTTTGATGGATGGAGAAGAACCTTTGCCAATGCTTCCAAGTTACAAGAACTTCAAGGGTACTATTGAAGAACTGGCTCC	16	104	1
T00103	GeneExpression	VCAM1	NM_001078	3,4	chr1	101188828	69M1283N66M	Plus	AATTACACATTGATGAAATGGATTCTGTGCCCACAGTAAGGCAGGCTGTAAAAGAATTGCAAGTCTACATATCACCCAAGAATACAGTTATTTCTGTGAATCCATCCACAAAGCTGCAAGAAGGTGGCTCTGTGA	16	105	1
T00104	GeneExpression	ZAP70	NM_001079	4,5	chr2	98341603	113M7630N26M	Plus	AAGCTCATTGCTACGACGGCCCACGAGCGGATGCCCTGGTACCACAGCAGCCTGACGCGTGAGGAGGCCGAGCGCAAACTTTACTCTGGGGCGCAGACCGACGGCAAGTTCCTGCTGAGGCCGCGGAAGGAGCAGGGCA	16	109	1
T00105	GeneExpression	LILRB2	NM_001080978	5,6	chr19	54782879	49M236N85M	Minus	CCCTATGTGTGGTCTTCACCCAGTGATCTCCTGGAGCTCCTGGTCCCAGGTGTTTCTAAGAAGCCATCACTCTCAGTGCAGCCGGGTCCTGTCGTGGCCCCTGGGGAAAGCCTGACCCTCCAGTGTGTCTCTGA	16	104	1
T00106	None		NM_001130917		chr19	55086452	49M222N85M	Plus	CCCTATGTGTGGTCTCTACCCAGTGATCTCCTGGAGCTCCTGGTCCCAGGTGTTTCTAAGAAGCCATCACTCTCAGTGCAGCCAGGTCCTATGGTGGCCCCCGGGGAGAGCCTGACCCTCCAGTGTGTCTCTGA	16	104	-1
T00107	None		NM_006863		chr19	55106819	49M236N85M	Plus	CCCTATGTGTGGTCTCTACCCAGTGATCTCCTGGAGCTCCTGGTCCTAGGTGTTTCTAAGAAGCCATCACTCTCAGTGCAGCCAGGTCCTATAGTGGCCCCTGGGGAGAGCCTGACCCTCCAGTGTGTCTCTGA	16	104	-2
T00108	GeneExpression	LILRB1	NM_001081637	10,11	chr19	55146116	99M340N30M	Plus	TGATCGGCATCTTGGTGGCCGTCATCCTACTGCTCCTCCTCCTCCTCCTCCTCTTCCTCATCCTCCGACATCGACGTCAGGGCAAACACTGGACATCGACCCAGAGAAAGGCTGATTTCCAACATCCTG	16	99	1
T00109	None		NM_001080978		chr19	54780281	99M350N30M	Minus	TGATCGGCATCTTGGTGGCCGTCGTCCTACTGCTCCTCCTCCTCCTCCTCCTCTTCCTCATCCTCCGACATCGACGTCAGGGCAAACACTGGACATCGACCCAGAGAAAGGCTGATTTCCAACATCCTG	16	99	-1
T00110	GeneExpression	XAGE1B	NM_001097594	3,4	chrX	52241196	58M2590N51M	Plus	TCCGGCGTCAAGGTGAAGATAATACCTAAAGAGGAACACTGTAAAATGCCAGAAGCAGGTGAAGAGCAACCACAAGTTTAAATGAAGACAAGCTGAAACAACGCAAGCT	16	79	1
T00111	None		NM_001097592_2		chrX	52255279	58M2590N51M	Minus	TCCGGCGTCAAGGTGAAGATAATACCTAAAGAGGAACACTGTAAAATGCCAGAAGCAGGTGAAGAGCAACCACAAGTTTAAATGAAGACAAGCTGAAACAACGCAAGCT	16	79	-1
T00112	None		NM_001097604_1		chrX	52514147	58M2590N51M	Plus	TCCGGCGTCAAGGTGAAGATAATACCTAAAGAGGAACACTGTAAAATGCCAGAAGCAGGTGAAGAGCAACCACAAGTTTAAATGAAGACAAGCTGAAACAACGCAAGCT	16	79	-2
T00113	None		NM_001097605_3		chrX	52528219	58M2590N51M	Minus	TCCGGCGTCAAGGTGAAGATAATACCTAAAGAGGAACACTGTAAAATGCCAGAAGCAGGTGAAGAGCAACCACAAGTTTAAATGAAGACAAGCTGAAACAACGCAAGCT	16	79	-3
T00114	None		NM_001097604_3		chrX	52541113	58M2590N51M	Minus	TCCGGCGTCAAGGTGAAGATAATACCTAAAGAGGAACACTGTAAAATGCCAGAAGCAGGTGAAGAGCAACCACAAGTTTAAATGAAGACAAGCTGAAACAACGCAAGCT	16	79	-4
T00115	GeneExpression	ENTPD1	NM_001098175	5,6	chr10	97604313	80M721N58M	Plus	GTGCCAGGATCATTACTGGCCAAGAGGAAGGTGCCTATGGCTGGATTACTATCAACTATCTGCTGGGCAAATTCAGTCAGAAAACAAGGTGGTTCAGCATAGTCCCATATGAAACCAATAATCAGGAAACCTTTGGAG	16	108	1
T00116	None		ENST00000483213		chr10	97604313	80M721N58M	Plus	GTGCCAGGATCATTACTGGCCAAGAGGAAGGTGCCTATGGCTGGATTACTATCAACTATCTGCTGGGCAAATTCAGTCAGAAAACAAGGTGGTTCAGCATAGTCCCATATGAAACCAATAATCAGGAAACCTTTGGAG	16	108	-1
T00117	GeneExpression	GPR18	NM_001098200	1,2	chr13	99908081	53M2247N80M	Minus	GTGGAAGTGCTGAAAAATGCTCATCTCTCACACAGACTTTTGATGGACAGGAGTTTCTAAGTATCATGCCTACCAACAAGCTGTAAAATGATCACCCTGAACAATCAAGATCAACCTGTCCCTTTTAACAGCT	16	103	1
T00118	GeneExpression		NM_005292		chr13	99908081	53M1634N192M421N80M	Minus	GTGGAAGTGCTGAAAAATGCTCATCTCTCACACAGACTTTTGATGGACAGGAGGTGCTGCTTTCTGTGAACCACTGAAGTAGAGCAGCTGAAATCACAAAACCTGGAAGACTTGGCTTTACGTACTCCCAATTGTGCACTAGAAAACAGCTCATCTATTGCTCTAACAGTCTAGTTCTTGATCTGCTGACCATGACACAAAACATTGCTGTTTCTCAACCTATGATAATTTAAAGAGAACATAAGTTTCTAAGTATCATGCCTACCAACAAGCTGTAAAATGATCACCCTGAACAATCAAGATCAACCTGTCCCTTTTAACAGCT	16	295	2
T00119	GeneExpression	GAGE12J	NM_001098406	2,3	chrX	49179678	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGACCCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAACGTCA	16	117	1
T00120	GeneExpression	GAGE10	NM_001098413	2,3	chrX	49161344	76M463N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGTCTAGACCAAGACTCTATGTAGAGCCCCCTGAAATGATTGGGCCTATGCTGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAACGTCA	16	114	2
T00121	GeneExpression	GAGE13	NM_001098412	2,3	chrX	49189221	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	1
T00122	None		NM_001098413		chrX	49161344	76M463N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGTCTAGACCAAGACTCTATGTAGAGCCCCCTGAAATGATTGGGCCTATGCTGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	114	-1
T00123	None		NM_001098406		chrX	49179678	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGACCCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-2
T00124	None		NM_001098407_2		chrX	49198724	76M465N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	114	-3
T00125	None		NM_001098407		chrX	49208277	76M464N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	114	-4
T00126	None		NM_001127212_2		chrX	49236836	76M465N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	114	-5
T00127	None		NM_001474		chrX	49217776	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-6
T00128	None		NM_001098407_1		chrX	49227299	76M465N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	114	-7
T00129	None		NM_001127199_3		chrX	49297940	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-8
T00130	None		NM_001127199_4		chrX	49307496	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-9
T00131	None		NM_001127199_5		chrX	49317052	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-10
T00132	None		NM_001127199_2		chrX	49326605	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-11
T00133	None		NM_001127199		chrX	49336163	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-12
T00134	None		NM_001127199_1		chrX	49345712	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-13
T00135	None		NM_001127212_3		chrX	49355259	76M465N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	114	-14
T00136	None		NM_001468		chrX	49364783	79M465N68M	Plus	TTGGCGAGGAAGATCGACCTATTATTGGCCTAGACCAAGGCGCTATGTACAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAATGTCA	16	117	-15
T00137	GeneExpression	HLA-F	NM_001098479	1,2	chr6	29691202	103M130N31M	Plus	GCGGGACTCATATTTTTCCCAGACGCGGAGGTTGGGGTCATGGCGCCCCGAAGCCTCCTCCTGCTGCTCTCAGGGGCCCTGGCCCTGACCGATACTTGGGCGGGCTCCCACTCCTTGAGGTATTTCAGCACCGC	16	104	1
T00138	GeneExpression		ENST00000427340		chr6	29691202	264M	Plus	GCGGGACTCATATTTTTCCCAGACGCGGAGGTTGGGGTCATGGCGCCCCGAAGCCTCCTCCTGCTGCTCTCAGGGGCCCTGGCCCTGACCGATACTTGGGCGGGTGAGTGCGGGGTCCAGAGAGAAACGGCCTCTGTGGGGAGGAGTGAGGGGCCCGCCCGGTGGGGGCGCAGGACTCAGGGAGCCGCCTCCGGAGGAGGGTCTGGCGGGTCTCAGCCCCTCCTCGCCCCCAGGCTCCCACTCCTTGAGGTATTTCAGCACCGC	16	234	2
T00139	GeneExpression	AMICA1	NM_001098526	1,2	chr11	118085553	92M10054N49M	Minus	GAGTGCTCGCAGCAGTCTTTCAGTTGAGCTTGGGGACTGCAGCTGTGGGGAGATTTCAGTGCATTGCCTCCCCTGGGTGCTCTTCATCTTGGATTTGAAAGTTGAGAGCAGCATGTTTTGCCCACTGAAACTCATCCTGCT	16	111	1
T00140	GeneExpression	CCR5	NM_001100168	2,3	chr3	46412438	42M1903N97M	Plus	GAAGAGCTGAGACATCCGTTCCCCTACAAGAAACTCTCCCCGGGTGGAACAAGATGGATTATCAAGTGTCAAGTCCAATCTATGACATCAATTATTATACATCGGAGCCCTGCCAAAAAATCAATGTGAAGCAAATCGC	16	109	1
T00141	GeneExpression	LEXM	NM_001110533	8,9	chr1	55280648	65M1949N67M	Plus	CCCCATTCCTGTTGACCTCCAAGGGGTCAGGTGCAAAGGCCTGCCAGATGATTATGGGAAGCTGGAACCCAGTAGGTGTGGGCCGCTACCTCAACACCTGGCTGATGGAGACAAAGGACAGGCGGCAGCGAT	16	102	1
T00142	GeneExpression	CCR2	NM_001123396	1,2	chr3	46395604	65M3299N64M	Plus	ATCTGTTTGGTTCAGTTGCTGAGAAGCCTGACATACCAGGACTGCCTGAGACAAGCCACAAGCTGAACAGAGAAAGTGGATTGAACAAGGACGCATTTCCCCAGTACATCCACAACATGCTGTCCACAT	16	99	1
T00143	GeneExpression	TFRC	NM_001128148	9,10	chr3	195792443	109M1917N29M	Minus	CTGGATTCCCTTCCTTCAATCACACTCAGTTTCCACCATCTCGGTCATCAGGATTGCCTAATATACCTGTCCAGACAATCTCCAGAGCTGCTGCAGAAAAGCTGTTTGGGAATATGGAAGGAGACTGTCCCTCTGACT	16	108	1
T00144	GeneExpression	EIF2AK2	NM_001135651	2,3	chr2	37374901	66M1034N65M	Minus	TCTTCAGAATCAACATCCACACTTCCGTGATTATCTGCGTGCATTTTGGACAAAGCTTCCAACCAGGATACGGGAAGAAGAAATGGCTGGTGATCTTTCAGCAGGTTTCTTCATGGAGGAACTTAATACAT	16	101	1
T00145	GeneExpression	ALOX15B	NM_001141	9,10	chr17	7949993	80M152N57M	Plus	TCCCGCACACCCGATACACCCTGCACATCAACACACTCGCCCGGGAGCTGCTTATCGTGCCAGGGCAGGTGGTGGACAGGTCCACAGGCATCGGCATTGAAGGCTTCTCTGAGTTGATACAGAGGAACATGAAGCAG	16	107	1
T00146	GeneExpression	CMKLR1	NM_001142345	1,2	chr12	108687402	98M26880N40M	Minus	GATTCTGCCCACGGAAGGAGACATGGAGGAGGAAGAGGCTGAGGGGAAGATGGAAGAAGGAGGGAAGGAAGGAGAAATCTTTGCTTTTGGGTAATCAGGTGTTTCTAGCTGTGTACAGGGACTGATTGGCTGAGGACT	16	108	1
T00147	GeneExpression	ITGAM	NM_001145808	26,27	chr16	31341412	74M143N63M	Plus	GTACGTGCCACACCAAGGAGCGCTTGCCCTCTCACTCCGACTTTCTGGCTGAGCTTCGGAAGGCCCCCGTGGTGAACTGCTCCATCGCTGTCTGCCAGAGAATCCAGTGTGACATCCCGTTCTTTGGCATCCAGGAA	16	107	1
T00148	GeneExpression	CD244	NM_001166663	3,4	chr1	160808747	43M2160N93M	Minus	CACACCCTGAATCTCACTCAGGACTGTCAGAATGCCCATCAGGAATTCAGATTTTGGCCGTTTTTGGTGATCATCGTGATTCTAAGCGCACTGTTCCTTGGCACCCTTGCCTGCTTCTGTGTGTGGAGGAGAAAGA	16	106	1
T00149	GeneExpression	CX3CR1	NM_001171174	1,2	chr3	39307935	85M15090N75M	Minus	GAGAGAACCCCTGGAGGCGTTTAAGTTGGCAGACTTGGATTTCAGGAAGAGCTCTCTGGCTTCTGGGTGGAGAATGGCCAGTGGGGCCTTCACCATGGATCAGTTCCCTGAATCAGTGACAGAAAACTTTGAGTACGATGATTTGGCTGAGGCCTGTTAT	16	130	1
T00150	GeneExpression	VEGFA	NM_001171623	7,8	chr6	43749806	19M2453N117M	Plus	TAAACGAACGTACTTGCAGATGTGACAAGCCGAGGCGGTGAGCCGGGCAGGAGGAAGGAGCCTCCCTCAGGGTTTCGGGAACCAGATCTCTCACCAGGAAAGACTGATACAGAACGATCGATACAGAAACCACGCT	16	106	1
T00151	GeneExpression	ZEB1	NM_001174093	1,2	chr10	31608159	63M141744N69M	Plus	GGATCATGGCGGATGGCCCCAGGTGTAAGCGCAGAAAGCAGGCGAACCCGCGGCGCAATAACGTTACAAATTATAATACTGTGGTAGAAACAAATTCAGATTCAGATGATGAAGACAAACTGCATATTGTGG	16	102	1
T00152	GeneExpression		ENST00000559858		chr10	31608159	63M35854N46M105844N69M	Plus	GGATCATGGCGGATGGCCCCAGGTGTAAGCGCAGAAAGCAGGCGAACCCGCGGCGCAATAACGCTGTTTAAGGAAGACAGAGCAGGCATTGGATAATATTCTTATTAAGTTACAAATTATAATACTGTGGTAGAAACAAATTCAGATTCAGATGATGAAGACAAACTGCATATTGTGG	16	148	2
T00153	GeneExpression		ENST00000437844		chr10	31608159	63M53725N156M13950N143M73770N69M	Plus	GGATCATGGCGGATGGCCCCAGGTGTAAGCGCAGAAAGCAGGCGAACCCGCGGCGCAATAACGTTTTCAGTTTAAATTCTCAACTGGCAATTGGCCGAAAACTCCCATCTGAAGACATGATCATCCAAATGTCATTTTGTGATTTGGCTACTGTCTGCTTGACATAGGAAAGCACTATCAAGAAAGACTAATGGAGTGACTATCAAAAGGAAGTCAATGGACAACCTTAAACTTCCACCACAAGAGGAATATAAAGAGGTCCCTCCTGCACCAAGAAAGATCTGCAGATCTTTTTCAGTGTTCTTGGAGGTGTGGGGTGTGAGAACTTGATCAGTTTGTGTCAGCCACCTTGTTCTCTAAAGTTACAAATTATAATACTGTGGTAGAAACAAATTCAGATTCAGATGATGAAGACAAACTGCATATTGTGG	16	401	3
T00154	GeneExpression	MX1	NM_001178046	3,4	chr21	42803993	110M3661N25M	Plus	GGAAGATGGTTGTTTCCGAAGTGGACATCGCAAAAGCTGATCCAGCTGCTGCATCCCACCCTCTATTACTGAATGGAGATGCTACTGTGGCCCAGAAAAATCCAGGCTCGGTGGCTGAGAACAACCTGTGCAGCC	16	105	1
T00155	GeneExpression	CD19	NM_001178098	8,9	chr16	28948383	75M134N72M	Plus	CCCCGTCTTATGGAAACCCGAGCAGCGACGTCCAGGCGGATGGAGCCTTGGGGTCCCGGAGCCCGCCGGGAGTGGGCCCAGAAGAAGAGGAAGGGGAGGGCTATGAGGAACCTGACAGTGAGGAGGACTCCGAGTTCTATGAGAACG	16	117	1
T00156	GeneExpression	FCRLA	NM_001184866	4,5	chr1	161681149	116M459N20M	Plus	CTCCATCACCGTGGTACAAAAGGCAGACAGCGGGCACTACCACTGCAGTGGCATCTTCCAGAGCCCTGGTCCTGGGATCCCAGAAACAGCATCTGTTGTGGCTATCACAGTCCAAGAACTGTTTCCAGCGCCAATT	16	106	1
T00157	GeneExpression	TNFRSF17	NM_001192	1,2	chr16	12059202	110M740N26M	Plus	GTGCTCCCAAAATGAATATTTTGACAGTTTGTTGCATGCTTGCATACCTTGTCAACTTCGATGTTCTTCTAATACTCCTCCTCTAACATGTCAGCGTTATTGTAATGCAAGTGTGACCAATTCAGTGAAAGGAACG	16	106	1
T00158	GeneExpression	HLA-DQB2	NM_001198858	1,2	chr6	32729626	54M1447N78M	Minus	CCGTGATGCTGGTGATGCTGAGCACCCCAGTGGCTGAGGCCAGAGACTTTCCCAAGGATTTCTTGGTCCAGTTTAAGGGCATGTGCTACTTCACCAACGGGACAGAGCGCGTGCGCGGTGTGGCCAGATACA	16	102	1
T00159	GeneExpression	PRDM1	NM_001198	2,3	chr6	106536268	57M7165N78M	Plus	GCGGAGGCATCCTTACCAAGGAATCTGCTTTTCAAGTATGCCACCAACAGTGAAGAGGTTATTGGAGTGATGAGTAAAGAATACATACCAAAGGGCACACGTTTTGGACCCCTAATAGGTGAAATCTACACCAAT	16	105	1
T00160	GeneExpression	PTPN7	NM_001199797	3,4	chr1	202126912	101M294N40M	Minus	AGGTCACCCTACACTTTCTGCGCACTGCTGGACACCCCCTTACCCGCTGGGCCCTTCAGCGCCAGCCACCCAGCCCCAAGCAACTGGAAGAAGAATTCTTGAAGATCCCTTCAAACTTTGTCAGCCCCGAAGACCTGGACA	16	111	1
T00161	GeneExpression		ENST00000467283		chr1	202126912	101M297N37M	Minus	AGGTCACCCTACACTTTCTGCGCACTGCTGGACACCCCCTTACCCGCTGGGCCCTTCAGCGCCAGCCACCCAGCCCCAAGCAACTGGAAGAAGAATTCTTGATCCCTTCAAACTTTGTCAGCCCCGAAGACCTGGACA	16	108	2
T00162	GeneExpression	CD27	NM_001242	2,3	chr12	6554636	86M4617N53M	Plus	GTGTGATCCTTGCATACCGGGGGTCTCCTTCTCTCCTGACCACCACACCCGGCCCCACTGTGAGAGCTGTCGGCACTGTAACTCTGGTCTTCTCGTTCGCAACTGCACCATCACTGCCAATGCTGAGTGTGCCTGTCGC	16	109	1
T00163	GeneExpression	CD40	NM_001250	3,4	chr20	44750949	49M251N89M	Plus	ACCTGGAACAGAGAGACACACTGCCACCAGCACAAATACTGCGACCCCAACCTAGGGCTTCGGGTCCAGCAGAAGGGCACCTCAGAAACAGACACCATCTGCACCTGTGAAGAAGGCTGGCACTGTACGAGTGAGGCC	16	108	1
T00164	GeneExpression	CD68	NM_001251	1,2	chr17	7482961	84M83N55M	Plus	CAGCCTAGCTGGACTTTGGGTGAGGCGGTTCAGCCATGAGGCTGGCTGTGCTTTTCTCGGGGGCCCTGCTGGGGCTACTGGCAGCCCAGGGGACAGGGAATGACTGTCCTCACAAAAAATCAGCTACTTTGCTGCCATC	16	109	1
T00165	GeneExpression		ENST00000581621		chr17	7482961	222M	Plus	CAGCCTAGCTGGACTTTGGGTGAGGCGGTTCAGCCATGAGGCTGGCTGTGCTTTTCTCGGGGGCCCTGCTGGGGCTACTGGCAGGTAAGGAGGAAGGAGGCTGAGGGGAGGGGGCCCCTGGGAGGGAGCCTGCCCTGGGTTGCTAACCATCTCCTCTCTGCCAAAAGCCCAGGGGACAGGGAATGACTGTCCTCACAAAAAATCAGCTACTTTGCTGCCATC	16	192	2
T00166	GeneExpression		ENST00000584502		chr17	7482961	84M122N16M	Plus	CAGCCTAGCTGGACTTTGGGTGAGGCGGTTCAGCCATGAGGCTGGCTGTGCTTTTCTCGGGGGCCCTGCTGGGGCTACTGGCAGCTACTTTGCTGCCATC	16	70	3
T00167	GeneExpression	CD70	NM_001252	1,2,3	chr19	6586385	69M704N34M3697N32M	Minus	ATCTGCCTCGTGGTGTGCATCCAGCGCTTCGCACAGGCTCAGCAGCAGCTGCCGCTCGAGTCACTTGGGTGGGACGTAGCTGAGCTGCAGCTGAATCACACAGGACCTCAGCAGGACCCCAGGCTATACTGGCAG	16	105	1
T00168	GeneExpression	CCR1	NM_001295	1,2	chr3	46245712	22M3957N104M	Minus	GACAAAGTCCCTTGGAACCAGAGAGAAGCCGGGATGGAAACTCCAAACACCACAGAGGACTATGACACGACCACAGAGTTTGACTATGGGGATGCAACTCCGTGCCAGAAGGTGAACGAGAGGGCC	16	96	1
T00169	GeneExpression	CTAG1B	NM_001327	1,2	chrX	153813678	62M671N66M	Plus	TCAGGGCTGAATGGATGCTGCAGATGCGGGGCCAGGGGGCCGGAGAGCCGCCTGCTTGAGTTCTACCTCGCCATGCCTTTCGCGACACCCATGGAAGCAGAGCTGGCCCGCAGGAGCCTGGCCCAGGA	16	98	1
T00170	None		NM_001327_1		chrX	153846464	62M671N66M	Minus	TCAGGGCTGAATGGATGCTGCAGATGCGGGGCCAGGGGGCCGGAGAGCCGCCTGCTTGAGTTCTACCTCGCCATGCCTTTCGCGACACCCATGGAAGCAGAGCTGGCCCGCAGGAGCCTGGCCCAGGA	16	98	-1
T00171	GeneExpression	FYB	NM_001465	2,3	chr5	39153597	25M48221N110M	Minus	TTCCACAAAACCTCTTCTGGAAACAGTACTAGCAAAGGCCAGACGTCTTACTCAACAACTTCCCTGCCACCACCTCCACCATCCCATCCGGCCAGCCAACCACCATTGCCAGCATCTCACCCATCACAACCACCA	16	105	1
T00172	GeneExpression	GAGE2C	NM_001472	2,3	chrX	49227299	76M465N68M	Plus	TTGGCGAGGAAGATCGACCTATCGGCCTAGACCAAGACGCTACGTAGAGCCTCCTGAAATGATTGGGCCTATGCGGCCCGAGCAGTTCAGTGATGAAGTGGAACCAGCAACACCTGAAGAAGGGGAACCAGCAACTCAACGTCA	16	114	1
T00173	GeneExpression	CXCR3	NM_001504	1,2	chrX	70837237	85M978N73M	Minus	GGTTTCCAACCACAAGCACCAAAGCAGAGGGGCAGGCAGCACACCACCCAGCAGCCAGAGCACCAGCCCAGCCATGGTCCTTGAGGTGAGTGACCACCAAGTGCTAAATGACGCCGAGGTTGCCGCCCTCCTGGAGAACTTCAGCTCTTCCTATGACT	16	128	1
T00174	GeneExpression	CXCL1	NM_001511	3,4	chr4	74735661	46M531N87M	Plus	CTGCATCCCCCATAGTTAAGAAAATCATCGAAAAGATGCTGAACAGTGACAAATCCAACTGACCAGAAGGGAGGAGGAAGCTCACTGGTGGCTGTTCCTGAAGGAGGCCCTGCCCTTATAGGAACAGAAGAGG	16	103	1
T00175	GeneExpression	HIF1A	NM_001530	8,9	chr14	62200893	111M2603N22M	Plus	GATGCTTGCCAAAAGAGGTGGATATGTCTGGGTTGAAACTCAAGCAACTGTCATATATAACACCAAGAATTCTCAACCACAGTGCATTGTATGTGTGAATTACGTTGTGAGTGGTATTATTCAGCACGACTTG	16	103	1
T00176	GeneExpression	IFIT2	NM_001547	1,2	chr10	91061814	72M3833N59M	Plus	AAGATTTCTGAAGAGTGCAGCTGCCTGAACCGAGCCCTGCCGAACAGCTGAGAATTGCACTGCAACCATGAGTGAGAACAATAAGAATTCCTTGGAGAGCAGCCTACGGCAACTAAAATGCCATTTCACCT	16	101	1
T00177	GeneExpression	IFIT1	NM_001548	1,2	chr10	91152445	30M9563N102M	Plus	AACGGCTGCCTAATTTACAGCAACCATGAGTACAAATGGTGATGATCATCAGGTCAAGGATAGTCTGGAGCAATTGAGATGTCACTTTACATGGGAGTTATCCATTGATGACGATGAAATGCCTGATTTAGA	16	102	1
T00178	GeneExpression		NM_001270928		chr10	91152445	30M7172N114M2277N102M	Plus	AACGGCTGCCTAATTTACAGCAACCATGAGGAAAGGCCACTTAAGGATGCAGCAAGAAGGAGCCATCTGCAATCCAGGAAGAAATTCCTTGCCAGGAACCAAATTGGTTGTCACCTTCATCTAGGACTTCTAGCCTCGAGAACTTACAAATGGTGATGATCATCAGGTCAAGGATAGTCTGGAGCAATTGAGATGTCACTTTACATGGGAGTTATCCATTGATGACGATGAAATGCCTGATTTAGA	16	216	2
T00179	GeneExpression		NM_001270929		chr10	91152445	30M7177N109M2277N102M	Plus	AACGGCTGCCTAATTTACAGCAACCATGAGGCCACTTAAGGATGCAGCAAGAAGGAGCCATCTGCAATCCAGGAAGAAATTCCTTGCCAGGAACCAAATTGGTTGTCACCTTCATCTAGGACTTCTAGCCTCGAGAACTTACAAATGGTGATGATCATCAGGTCAAGGATAGTCTGGAGCAATTGAGATGTCACTTTACATGGGAGTTATCCATTGATGACGATGAAATGCCTGATTTAGA	16	211	3
T00180	GeneExpression		NM_001270927		chr10	91152445	30M389N97M9077N102M	Plus	AACGGCTGCCTAATTTACAGCAACCATGAGGTTCTTTACCACAGAGAAAAAGCAGGACCCACAAGAATGTGAAAGCCTCAGTCTTGCAGCCTCTCTGATGTCTTGTGGGTAATACAGTGGAGATGTGTACAAATGGTGATGATCATCAGGTCAAGGATAGTCTGGAGCAATTGAGATGTCACTTTACATGGGAGTTATCCATTGATGACGATGAAATGCCTGATTTAGA	16	199	4
T00181	GeneExpression		NM_001270930		chr10	91152445	30M389N235M8939N102M	Plus	AACGGCTGCCTAATTTACAGCAACCATGAGGTTCTTTACCACAGAGAAAAAGCAGGACCCACAAGAATGTGAAAGCCTCAGTCTTGCAGCCTCTCTGATGTCTTGTGGGTAATACAGTGGAGATGTGGTAGGAAAAGCTCACAGCCTTCCTCCATAGGCTTCTGGTCTCACTTTCTGCACTGCTGGCCTCTTACAACAGGTTTTCGCAATCAGGCTGAGCTTAAGATAAACAGATTGCCTCCTCCCTGGAAAATCTAGGCTCTTGTACAAATGGTGATGATCATCAGGTCAAGGATAGTCTGGAGCAATTGAGATGTCACTTTACATGGGAGTTATCCATTGATGACGATGAAATGCCTGATTTAGA	16	337	5
T00182	GeneExpression	CXCR2	NM_001557	2,3	chr2	218994059	30M5411N108M	Plus	TGTCCTACAGGTGAAAAGCCCAGCGACCCAGTCAGGATTTAAGTTTACCTCAAAAATGGAAGATTTTAACATGGAGAGTGACAGCTTTGAAGATTTCTGGAAAGGTGAAGATCTTAGTAATTACAGTTACAGCTCTAC	16	108	1
T00183	GeneExpression	IL10RA	NM_001558	2,3	chr11	117859129	89M939N46M	Plus	TTTGAAGCAGAATTTTTCCACCACATCCTCCACTGGACACCCATCCCAAATCAGTCTGAAAGTACCTGCTATGAAGTGGCGCTCCTGAGGTATGGAATAGAGTCCTGGAACTCCATCTCCAACTGTAGCCAGACC	16	105	1
T00184	GeneExpression	TNFRSF9	NM_001561	8,9	chr1	7980911	62M12238N73M	Minus	CACGCTCCGTTTCTCTGTTGTTAAACGGGGCAGAAAGAAACTCCTGTATATATTCAAACAACCATTTATGAGACCAGTACAAACTACTCAAGAGGAAGATGGCTGTAGCTGCCGATTTCCAGAAGAAGAAGAAGG	16	105	1
T00185	GeneExpression	IL18	NM_001562	1,2	chr11	112025736	88M8844N49M	Minus	CCTGCTGCAGTCTACACAGCTTCGGGAAGAGGAAAGGAACCTCAGACCTTCCAGATCGCTTCCTCTCGCAACAAACTATTTGTCGCAGGAATAAAGATGGCTGCTGAACCAGTAGAAGACAATTGCATCAACTTTGT	16	107	1
T00186	GeneExpression		ENST00000528832		chr11	112025736	88M8823N70M	Minus	CCTGCTGCAGTCTACACAGCTTCGGGAAGAGGAAAGGAACCTCAGACCTTCCAGATCGCTTCCTCTCGCAACAAACTATTTGTCGCAGATGGCTCTTTGCTTTCATTAGGAATAAAGATGGCTGCTGAACCAGTAGAAGACAATTGCATCAACTTTGT	16	128	2
T00187	GeneExpression	CXCL10	NM_001565	3,4	chr4	76943011	45M417N91M	Minus	ATCGAAGGCCATCAAGAATTTACTGAAAGCAGTTAGCAAGGAAAGGTCTAAAAGATCTCCTTAAAACCAGAGGGGAGCAAAATCGATGCAGTGCTTCCAAGGATGGACCACACAGAGGCTGCCTCTCCCATCACTT	16	106	1
T00188	GeneExpression	AIF1	NM_001623	5,6	chr6	31584220	64M309N73M	Plus	AGACGTTCAGCTACCCTGACTTTCTCAGGATGATGCTGGGCAAGAGATCTGCCATCCTAAAAATGATCCTGATGTATGAGGAAAAAGCGAGAGAAAAGGAAAAGCCAACAGGCCCCCCAGCCAAGAAAGCTATCTCT	16	107	1
T00189	GeneExpression		NM_004847_3		chr6	31584220	446M	Plus	AGACGTTCAGCTACCCTGACTTTCTCAGGATGATGCTGGGCAAGAGATCTGCCATCCTAAAAATGTGAGTGTCAATTTCCAACCTCCCCTGTACTTACCTGTTTTCTCCTCCCCCATCCCTACCCTTGTCCACAGGCTCAACATTTCTACACGTTGCCCATCATCCCTTCTTCCATCCTTAGAGGGACCCTTCCAAGGTCCCGACCCCATCCCTATCCATAGTCCTGGTCCCCAGAAACTCCAACCCCTGCCCTTCCTCTTCCCCCTTCCACCCTCACATCCCCATCCCCTTCTAGCCTTTCCTAGCACCCTATGATTTATTCCCTTGAGAGGAGTGTTCCCTGATCCCTGTGCCTCTTCCCATCTCAACCAGGATCCTGATGTATGAGGAAAAAGCGAGAGAAAAGGAAAAGCCAACAGGCCCCCCAGCCAAGAAAGCTATCTCT	16	416	2
T00190	GeneExpression	BCL6	NM_001706	8,9	chr3	187442799	70M420N68M	Minus	AACCCACACTCGAATTCACTCTGGAGAGAAGCCCTACAAATGCGAAACCTGCGGAGCCAGATTTGTACAGGTGGCCCACCTCCGTGCCCATGTGCTTATCCACACTGGTGAGAAGCCCTATCCCTGTGAAATCTGTGG	16	108	1
T00191	GeneExpression	CEACAM1	NM_001712	4,5	chr19	43023311	62M2031N77M	Minus	CCACGCCAATAACTCAGTCACTGGCTGCAACAGGACCACAGTCAAGACGATCATAGTCACTGAGCTAAGTCCAGTAGTAGCAAAGCCCCAAATCAAAGCCAGCAAGACCACAGTCACAGGAGATAAGGACTCTGTGAAC	16	109	1
T00192	GeneExpression	CXCR5	NM_001716	1,2	chr11	118754612	90M9603N40M	Plus	AGACAGTGACCAGTCTGGTGACTCACAGCCGGCACAGCCATGAACTACCCGCTAACGCTGGAAATGGACCTCGAGAACCTGGAGGACCTGTTCTGGGAACTGGACAGATTGGACAACTATAACGACACCT	16	100	1
T00193	GeneExpression	CD1C	NM_001765	5,6	chr1	158263058	35M152N100M	Plus	CTAATAGTCCTTGTGTTATGGTTTAAGAAGCACTGCTCATATCAGGACATCCTGTGAGACTCTTCCCCCTGACTCCCCCATTGTGTTAAGAACCCAGCAACCCAGGAGCCTAGTACAATATAGTGATGCCATCCC	16	105	1
T00194	GeneExpression	CD1D	NM_001766	4,5	chr1	158152045	56M567N82M	Plus	CCCCCAATTTGTCAGTGGCCTCCTTGAGTCAGGGAAGTCGGAACTGAAGAAGCAAGTGAAGCCCAAGGCCTGGCTGTCCCGTGGCCCCAGTCCTGGCCCTGGCCGTCTGCTGCTGGTGTGCCATGTCTCAGGATTCTA	16	108	1
T00195	GeneExpression	CD2	NM_001767	2,3	chr1	117297497	77M5450N56M	Plus	GGATATCTACAAGGTATCAATATATGATACAAAAGGAAAAAATGTGTTGGAAAAAATATTTGATTTGAAGATTCAAGAGAGGGTCTCAAAACCAAAGATCTCCTGGACTTGTATCAACACAACCCTGACCTGT	16	103	1
T00196	GeneExpression	CD22	NM_001771	5,6	chr19	35828865	60M146N78M	Plus	GTCAGGTCTCCAATGACGTGGGCCCGGGAAGGTCGGAAGAAGTGTTCCTGCAAGTGCAGTATGCCCCGGAACCTTCCACGGTTCAGATCCTCCACTCACCGGCTGTGGAGGGAAGTCAAGTCGAGTTTCTTTGCATGT	16	108	1
T00197	GeneExpression	CD33	NM_001772	2,3	chr19	51728768	87M204N50M	Plus	GGGATAATGGTTCATACTTCTTTCGGATGGAGAGAGGAAGTACCAAATACAGTTACAAATCTCCCCAGCTCTCTGTGCATGTGACAGACTTGACCCACAGGCCCAAAATCCTCATCCCTGGCACTCTAGAACCCGGC	16	107	1
T00198	GeneExpression	CD37	NM_001774	5,6	chr19	49841199	88M670N52M	Plus	GGACGTCGTAGAGAAAACCATCCAAAAGTACGGCACCAACCCCGAGGAGACCGCGGCCGAGGAGAGCTGGGACTATGTGCAGTTCCAGCTGCGCTGCTGCGGCTGGCACTACCCGCAGGACTGGTTCCAAGTCCTCATCC	16	110	1
T00199	GeneExpression	CD38	NM_001775	3,4	chr4	15826537	103M9200N37M	Plus	CATCAGTTCACACAGGTCCAGCGGGACATGTTCACCCTGGAGGACACGCTGCTAGGCTACCTTGCTGATGACCTCACATGGTGTGGTGAATTCAACACTTCCAAAATAAACTATCAATCTTGCCCAGACTGGAGAAAGGA	16	110	1
T00200	GeneExpression		ENST00000510674		chr4	15826537	85M9218N37M	Plus	CATCAGTTCACACAGGTCCAGCGGGACATGTTCACCCTGGAGGACACGCTGCTAGGCTACCTTGCTGATGACCTCACATGGTGTGAAATAAACTATCAATCTTGCCCAGACTGGAGAAAGGA	16	92	2
T00201	GeneExpression	CD47	NM_001777	5,6	chr3	107777202	61M1022N75M	Minus	GGTTTAATTGTGACTTCTACAGGGATATTAATATTACTTCACTACTATGTGTTTAGTACAGCGATTGGATTAACCTCCTTCGTCATTGCCATATTGGTTATTCAGGTGATAGCCTATATCCTCGCTGTGGTTGGAC	16	106	1
T00202	GeneExpression	CD48	NM_001778	3,4	chr1	160648849	61M2070N73M	Minus	GTCAGCAATTCTGTGAGCAGCAAGAATGGCACGGTCTGCCTCAGTCCACCCTGTACCCTGGCCCGGTCCTTTGGAGTAGAATGGATTGCAAGTTGGCTAGTGGTCACGGTGCCCACCATTCTTGGCCTGTTACT	16	104	1
T00203	GeneExpression	CD63	NM_001780	6,7	chr12	56119630	88M224N51M	Minus	GTCGAAGAACCGAGTCCCCGACTCCTGCTGCATTAATGTTACTGTGGGCTGTGGGATTAATTTCAACGAGAAGGCGATCCATAAGGAGGGCTGTGTGGAGAAGATTGGGGGCTGGCTGAGGAAAAATGTGCTGGTGGTA	16	109	1
T00204	GeneExpression	CD69	NM_001781	2,3	chr12	9907808	89M1035N50M	Minus	TGAAGGGTCCTTCCAAGTTCCTGTCCTGTGTGCTGTAATGAATGTGGTCTTCATCACCATTTTAATCATAGCTCTCATTGCCTTATCAGTGGGCCAATACAATTGTCCAGGCCAATACACATTCTCAATGCCATCAGAC	16	109	1
T00205	GeneExpression	CD79A	NM_001783	1,2	chr19	42381358	96M1606N41M	Plus	CAACCCACTGGGAGAAGATGCCTGGGGGTCCAGGAGTCCTCCAAGCTCTGCCTGCCACCATCTTCCTCCTCTTCCTGCTGTCTGCTGTCTACCTGGGCCCTGGGTGCCAGGCCCTGTGGATGCACAAGGTCCCAGCA	16	107	1
T00206	GeneExpression	CDK1	NM_001786	7,8	chr10	62551932	116M1587N17M	Plus	TGTGGCCAGAAGTGGAATCTTTACAGGACTATAAGAATACATTTCCCAAATGGAAACCAGGAAGCCTAGCATCCCATGTCAAAAACTTGGATGAAAATGGCTTGGATTTGCTCTCGAAAATGTTAATCTATGA	16	103	1
T00207	GeneExpression	CD52	NM_001803	1,2	chr1	26644465	98M2099N38M	Plus	ACCTAAAAAGCTGCTACCAAGACAGCCACGAAGATCCTACCAAAATGAAGCGCTTCCTCTTCCTCCTACTCACCATCAGCCTCCTGGTTATGGTACAGATACAAACTGGACTCTCAGGACAAAACGACACCAGCCA	16	106	1
T00208	GeneExpression		ENST00000470468		chr1	26644465	98M456N113M1530N38M	Plus	ACCTAAAAAGCTGCTACCAAGACAGCCACGAAGATCCTACCAAAATGAAGCGCTTCCTCTTCCTCCTACTCACCATCAGCCTCCTGGTTATGGTACAGAGAGAAGCCTGGATGTTCAGGAATGCAAAGAAGACAGGACTCTCCCATTTCAGAAACAACTGGAGTCTCAAAAGCGACTGCTATTCCAGGAGGCAGCTTTGGTAGCATCCCAGATACAAACTGGACTCTCAGGACAAAACGACACCAGCCA	16	219	2
T00209	GeneExpression	CEACAM8	NM_001816	3,4	chr19	43093134	76M418N57M	Minus	GTAGGACCCTATGAATGTGAAATACAGAACCCAGCGAGTGCAAACTTCAGTGACCCAGTCACCCTGAATGTCCTCTATGGCCCAGATGCCCCCACCATTTCCCCTTCAGACACCTATTACCATGCAGGGGTAA	16	103	1
T00210	GeneExpression	CCR7	NM_001838	2,3	chr17	38711954	18M3074N117M	Minus	CTCCTTGTCATTTTCCAGGTATGCCTGTGTCAAGATGAGGTCACGGACGATTACATCGGAGACAACACCACAGTGGACTACACTTTGTTCGAGTCTTTGTGCTCCAAGAAGGACGTGCGGAACTTTAAAGCCTGG	16	105	1
T00211	GeneExpression	FOXO1	NM_002015	1,2	chr13	41134917	55M104722N81M	Minus	GAGCGTGCCCTACTTCAAGGATAAGGGTGACAGCAACAGCTCGGCGGGCTGGAAGAATTCAATTCGTCATAATCTGTCCCTACACAGCAAGTTCATTCGTGTGCAGAATGAAGGAACTGGAAAAAGTTCTTGGTGG	16	106	1
T00212	GeneExpression	FUT4	NM_002033	1	chr11	94280145	139M	Plus	TCCCCTCACAGTCAATGCAGTGGTATAGCATATCCTCACATTTCTAGTGCCCTTGAGACTGTGCTATGGAACCAATCTTGAACATACATGCATTGACTTGACAAGTTACTGAGTAAGCAGCATATTCAGCAGGTGCCAC	16	109	1
T00213	GeneExpression	GBP1	NM_002053	5,6	chr1	89523882	96M606N36M	Minus	TGTGGACACTGAGAGATTTCTCCCTGGACTTGGAAGCAGATGGACAACCCCTCACACCAGATGAGTACCTGACATACTCCCTGAAGCTGAAGAAAGGTACCAGTCAAAAAGATGAAACTTTTAACCTGCCCA	16	102	1
T00214	GeneExpression	GZMK	NM_002104	2,3	chr5	54320542	94M5626N45M	Plus	TTATGGCCTCCATCCAGTATGGCGGACATCACGTTTGTGGAGGTGTTCTGATTGATCCACAGTGGGTGCTGACAGCAGCCCACTGCCAATATCGGTTTACCAAAGGCCAGTCTCCCACTGTGGTTTTAGGCGCACACTC	16	109	1
T00215	GeneExpression	HLA-A	NM_002116	2,3	chr6	29910706	98M241N33M	Plus	GTATTGGGACCAGGAGACACGGAATGTGAAGGCCCAGTCACAGACTGACCGAGTGGACCTGGGGACCCTGCGCGGCTACTACAACCAGAGCGAGGCCGGTTCTCACACCATCCAGATAATGTATGGCTGCG	16	101	1
T00216	GeneExpression		ENST00000495183		chr6	29910706	372M	Plus	GTATTGGGACCAGGAGACACGGAATGTGAAGGCCCAGTCACAGACTGACCGAGTGGACCTGGGGACCCTGCGCGGCTACTACAACCAGAGCGAGGCCGGTGAGTGACCCCGGCCGGGGGCGCAGGTCAGGACCCCTCATCCCCCACGGACGGGCCAGGTCGCCCACAGTCTCCGGGTCCGAGATCCACCCCGAAGCCGCGGGACCCCGAGACCCTTGCCCCGGGAGAGGCCCAGGCGCCTTTACCCGGTTTCATTTTCAGTTTAGGCCAAAAATCCCCCCGGGTTGGTCGGGGCTGGGCGGGGCTCGGGGGACTGGGCTGACCGCGGGGTCGGGGCCAGGTTCTCACACCATCCAGATAATGTATGGCTGCG	16	342	2
T00217	GeneExpression	HLA-C	NM_002117	4,5	chr6	31237785	57M124N78M	Minus	GATACACGTGCCATATGCAGCACGAGGGGCTGCAAGAGCCCCTCACCCTGAGCTGGGAGCCATCTTCCCAGCCCACCATCCCCATCATGGGCATCGTTGCTGGCCTGGCTGTCCTGGTTGTCCTAGCTGTCCTTG	16	105	1
T00218	GeneExpression	HLA-DMB	NM_002118	3,4	chr6	32903338	47M1519N92M	Minus	TGTGGTAGAGCACACTGGGGCTCCTGAGCCCATCCTTCGGGACTGGACACCTGGGCTGTCCCCCATGCAGACCCTGAAGGTTTCTGTGTCTGCAGTGACTCTGGGCCTGGGCCTCATCATCTTCTCTCTTGGTGTGATC	16	109	1
T00219	GeneExpression	HLA-DOA	NM_002119	1,2	chr6	32976019	119M1193N20M	Minus	CGGACTGAGACTGATTTGATTAAAGCACCAGAGTGTAATGGCCCTCAGAGCAGGGCTGGTCCTGGGGTTCCACACCCTGATGACCCTCCTGAGCCCGCAGGAGGCAGGGGCCACCAAGGCTGACCACATGGGCTCCTAC	16	109	1
T00220	GeneExpression		ENST00000467465		chr6	32976019	119M1050N163M	Minus	CGGACTGAGACTGATTTGATTAAAGCACCAGAGTGTAATGGCCCTCAGAGCAGGGCTGGTCCTGGGGTTCCACACCCTGATGACCCTCCTGAGCCCGCAGGAGGCAGGGGCCACCAAGGGGCCAGCCCAGTGTCAGAACAGGACTCTGTCCCCACACAGAACCCAGGACGGGGCCCAGGCTCAGGGACTCAACAATCACATATTGTGGATGAGACAGACACATTTTTTTCTCTCTCCTTGACCCTGAACTCGCCAAACACAGCTGACCACATGGGCTCCTAC	16	252	2
T00221	GeneExpression	HLA-DOB	NM_002120	1,2	chr6	32782974	22M1547N117M	Minus	ACTCAAGGCACAGACTCTCCAGAAGATTTTGTGATTCAGGCAAAGGCTGACTGTTACTTCACCAACGGGACAGAAAAGGTGCAGTTTGTGGTCAGATTCATCTTTAACTTGGAGGAGTATGTACGTTTCGACAGTGATG	16	109	1
T00222	GeneExpression	HLA-DPB1	NM_002121	1,2	chr6	33043862	57M4530N79M	Plus	TGACGGCGTTACTGATGGTGCTGCTCACATCTGTGGTCCAGGGCAGGGCCACTCCAGAGAATTACCTTTTCCAGGGACGGCAGGAATGCTACGCGTTTAATGGGACACAGCGCTTCCTGGAGAGATACATCTACAA	16	106	1
T00223	GeneExpression	HLA-DQA1	NM_002122	3,4	chr6	32609936	95M356N35M	Plus	GATCAGTTACCTCACCTTCCTCCCTTCTGCTGATGAGATTTATGACTGCAAGGTGGAGCACTGGGGCCTGGACCAGCCTCTTCTGAAACACTGGGAGCCTGAGATTCCAGCCCCTATGTCAGAGCTCACA	16	100	1
T00224	None		NM_020056_1		chr6	32713755	95M167N35M	Plus	GATCAGTTACCTCACCTTCCTCCCTTCTGCTGATGAGATTTATGACTGCAAGGTGGAGCACTGGGGCCTGGACGAGCCTCTTCTGAAACACTGGGAGCCTGAGATTCCAGCCCCTATGTCAGAGCTCACA	16	100	-1
T00225	GeneExpression		ENST00000460633		chr6	32609936	486M	Plus	GATCAGTTACCTCACCTTCCTCCCTTCTGCTGATGAGATTTATGACTGCAAGGTGGAGCACTGGGGCCTGGACCAGCCTCTTCTGAAACACTGGGGTAAGGATGAGTTTCATCATTTTTTGATTCTTTCTTGTCTGTCAAGTTCAGAACTTCCTGCCTTTTACTCCTATATCCAAAAACTTGTTTTCCACACTTCATGGGTTTCTTTTCTGTCTCTCTTTTTTTTTTGAAAGAATAAAGCAAAAAAAGCAGAGATTTATTGAAAATGAAAGTACACTCTACAGGATGGGAGTGGGCCTGCCACTTCATGGTTTTCTAATGATAGACTTCACTCTTCTCCCTAAGCCTGGGGCCTTGAGTCTTTGCAGAGCCAACCCTCTACCCCATCCCATCCCACACACATGCACATGAGCACACTCTGCATTCTGACCTCAACAACTTCACTTCCACAGAGCCTGAGATTCCAGCCCCTATGTCAGAGCTCACA	16	456	2
T00226	GeneExpression	HLA-DRB1	NM_002124	5,6	chr6	32546766	20M1142N116M	Minus	CTCTGGACTTCAGCCAACAGGATTCCTGAGCTGAAATGCAGATGACCACATTCAAGGAAGAACTTTCTGCCCCGGCTTTGCAGGATGAAAAGCTTTCCTGCTTGGCAGTTATTCTTCCACAAGAGAGGGCTTTCTC	16	106	1
T00227	GeneExpression	HLA-G	NM_002127	3,4	chr6	29796040	54M226N79M	Plus	CTGACAGAATGAACCTGCAGACCCTGCGCGGCTACTACAACCAGAGCGAGGCCAGTTCTCACACCCTCCAGTGGATGATTGGCTGCGACCTGGGGTCCGACGGACGCCTCCTCCGCGGGTATGAACAGTATGC	16	103	1
T00228	None		ENST00000494367		chr6	29974793	54M248N79M	Plus	CTGACAGAATGAACCTGCGGACCCTGCTCCGCTACTACAACCAGAGCGAGGCGGGGTATCACATCCTCCAGGGAATGTTTGGCTGCGACCTGGGGCCCGACGGGCGTCTCCTCCGCGGGTATGAACAGTATGC	16	103	-1
T00229	GeneExpression	IDO1	NM_002164	2,3	chr8	39775445	45M117N87M	Plus	CCTGATCTCATAGAGTCTGGCCAGCTTCGAGAAAGAGTTGAGAAGTTAAACATGCTCAGCATTGATCATCTCACAGACCACAAGTCACAGCGCCTTGCACGTCTAGTTCTGGGATGCATCACCATGGCATAT	16	102	1
T00230	GeneExpression	ID2	NM_002166	2,3	chr2	8823005	32M778N99M	Plus	TGACAGCAAAGCACTGTGTGGCTGAATAAGCGGTGTTCATGATTTCTTTTATTCTTTGCACAACAACAACAACAACAAATTCACGGAATCTTTTAAGTGCTGAACTTATTTTTCAACCATTTCACAAGGAG	16	101	1
T00231	GeneExpression	ID3	NM_002167	1,2	chr1	23885486	112M107N25M	Minus	GCTTAGCCAGGTGGAAATCCTACAGCGCGTCATCGACTACATTCTCGACCTGCAGGTAGTCCTGGCCGAGCCAGCCCCTGGACCCCCTGATGGCCCCCACCTTCCCATCCAGACAGCCGAGCTCACTCCGGAACTTG	16	107	1
T00232	GeneExpression	IFNB1	NM_002176	1	chr9	21077243	138M	Minus	CTGGACCATAGTCAGAGTGGAAATCCTAAGGAACTTTTACTTCATTAACAGACTTACAGGTTACCTCCGAAACTGAAGATCTCCTAGCCTGTGCCTCTGGGACTGGACAATTGCTTCAAGCATTCTTCAACCAGCAGA	16	108	1
T00233	GeneExpression	IL3RA	NM_002183	3,4	chrX	1464245	83M2996N48M	Plus	CAAAGGCTCAGCAGTTGACCTGGGACCTTAACAGAAATGTGACCGATATCGAGTGTGTTAAAGACGCCGACTATTCTATGCCGGCAGTGAACAATAGCTATTGCCAGTTTGGAGCAATTTCCTTATGTGAA	16	101	1
T00234	GeneExpression	IL7R	NM_002185	4,5	chr5	35871211	105M2266N33M	Plus	GACTTTGTGGTGACATTTAATACATCACACTTGCAAAAGAAGTATGTAAAAGTTTTAATGCACGATGTAGCTTACCGCCAGGAAAAGGATGAAAACAAATGGACGCATGTGAATTTATCCAGCACAAAGCTGACACTC	16	108	1
T00235	GeneExpression	IL12B	NM_002187	3,4	chr5	158749489	108M542N31M	Minus	GCCAGTACACCTGTCACAAAGGAGGCGAGGTTCTAAGCCATTCGCTCCTGCTGCTTCACAAAAAGGAAGATGGAATTTGGTCCACTGATATTTTAAAGGACCAGAAAGAACCCAAAAATAAGACCTTTCTAAGATGCGA	16	109	1
T00236	GeneExpression	IL13	NM_002188	3,4	chr5	131995426	95M346N46M	Plus	CCCTGGAATCCCTGATCAACGTGTCAGGCTGCAGTGCCATCGAGAAGACCCAGAGGATGCTGAGCGGATTCTGCCCGCACAAGGTCTCAGCTGGGCAGTTTTCCAGCTTGCATGTCCGAGACACCAAAATCGAGGTGGCCC	16	111	1
T00237	GeneExpression	IL17A	NM_002190	2,3	chr6	52052546	58M1249N60M	Plus	CCAATCCCAAAAGGTCCTCAGATTACTACAACCGATCCACCTCACCTTGGAATCTCCACCGCAATGAGGACCCTGAGAGATATCCCTCTGTGATCTGGGAGGCAAAGTGCCGCCACTT	16	88	1
T00238	GeneExpression	IRF1	NM_002198	6,7	chr5	131821968	42M183N98M	Minus	GCTACATGCAGGACTTGGAGGTGGAGCAGGCCCTGACTCCAGCACTGTCGCCATGTGCTGTCAGCAGCACTCTCCCCGACTGGCACATCCCAGTGGAAGTTGTGCCGGACAGCACCAGTGATCTGTACAACTTCCAGGTG	16	110	1
T00239	GeneExpression		ENST00000472045		chr5	131821968	323M	Minus	GCTACATGCAGGACTTGGAGGTGGAGCAGGCCCTGACTCCAGGTGAGCTGGTCCAGGTCTGGCAGGAGACCCCACAGGTCAGTGGGATGACTCTTTCTCTTGGAGGCATGGTGCTGGCACATGGTGGCCCATTAGTGCAGGCTGCAGGGTTGGTCGGAGGGCGCTCGATGTCTTGCAAACTAAGAAAGCACACAACCTTGACCTGTGGCTTCTGCTGTTCCCCAGCACTGTCGCCATGTGCTGTCAGCAGCACTCTCCCCGACTGGCACATCCCAGTGGAAGTTGTGCCGGACAGCACCAGTGATCTGTACAACTTCCAGGTG	16	293	2
T00240	GeneExpression	ISG20	NM_002201	3,4	chr15	89195446	96M3104N43M	Plus	ACTGACAGGCTGTTGTGGCGTGAGGCCAAGCTGGACCACTGCAGGCGTGTCTCCCTGCGGGTGCTGAGTGAGCGCCTCCTACACAAGAGCATCCAGAACAGCCTGCTTGGACACAGCTCGGTGGAAGATGCGAGGGCAA	16	109	1
T00241	GeneExpression		ENST00000546338		chr15	89195446	96M3109N38M	Plus	ACTGACAGGCTGTTGTGGCGTGAGGCCAAGCTGGACCACTGCAGGCGTGTCTCCCTGCGGGTGCTGAGTGAGCGCCTCCTACACAAGAGCATCCAGCCTGCTTGGACACAGCTCGGTGGAAGATGCGAGGGCAA	16	104	2
T00242	GeneExpression	ITGAE	NM_002208	29,30	chr17	3620029	73M3508N64M	Minus	GCAGATCCTTGGTGAAATATCTTTCAACAAATCTCTATATGAGGGACTGAATGCAGAGAACCACAGAACTAAGATCACTGTCGTCTTCCTGAAAGATGAGAAGTACCATTCTTTGCCTATCATCATTAAAGGCAGCG	16	107	1
T00243	GeneExpression	ITGAL	NM_002209	5,6	chr16	30490428	102M122N32M	Plus	TGTCTCGAACGTGTGACCAGAACACCTATCTGAGTGGCCTGTGTTACCTCTTCCGCCAGAATCTGCAGGGTCCCATGCTGCAGGGGCGCCCTGGTTTTCAGGAATGTATCAAGGGCAACGTAGACCTGGTATTT	16	104	1
T00244	GeneExpression	ITGB1	NM_002211	5,6	chr10	33215014	105M1984N24M	Minus	TTATGGACCTGTCTTACTCAATGAAAGACGATTTGGAGAATGTAAAAAGTCTTGGAACAGATCTGATGAATGAAATGAGGAGGATTACTTCGGACTTCAGAATTGGATTTGGCTCATTTGTGGAAAAGA	16	99	1
T00245	GeneExpression	KLRB1	NM_002258	2,3	chr12	9752385	85M1659N53M	Minus	TCACCTTGGCATCAATTTGCCCTGAAACTTAGCTGTGCTGGGATTATTCTCCTTGTCTTGGTTGTTACTGGGTTGAGTGTTTCAGTGACATCCTTAATACAGAAATCATCAATAGAAAAATGCAGTGTGGACATTCAA	16	108	1
T00246	GeneExpression	KLRD1	NM_002262	4,5	chr12	10464139	76M1794N59M	Plus	AACTTGGAACGAAAGTCGGCATCTCTGTGCTTCTCAGAAATCCAGCCTGCTTCAGCTTCAAAACACAGATGAACTGGATTTTATGAGCTCCAGTCAACAATTTTACTGGATTGGACTCTCTTACAGTGAGGAGCA	16	105	1
T00247	GeneExpression		ENST00000381908		chr12	10464139	76M1791N62M	Plus	AACTTGGAACGAAAGTCGGCATCTCTGTGCTTCTCAGAAATCCAGCCTGCTTCAGCTTCAAAACACAGATGAACTGCAGGATTTTATGAGCTCCAGTCAACAATTTTACTGGATTGGACTCTCTTACAGTGAGGAGCA	16	108	2
T00248	GeneExpression		ENST00000539374		chr12	10464139	80M1790N59M	Plus	AACTTGGAACGAAAGTCGGCATCTCTGTGCTTCTCAGAAATCCAGCCTGCTTCAGCTTCAAAACACAGATGAACTGGCATGATTTTATGAGCTCCAGTCAACAATTTTACTGGATTGGACTCTCTTACAGTGAGGAGCA	16	109	3
T00249	GeneExpression	LAG3	NM_002286	5,6	chr12	6884604	111M1715N28M	Plus	TTACCCTTCGACTAGAGGATGTGAGCCAGGCCCAGGCTGGGACCTACACCTGCCATATCCATCTGCAGGAACAGCAGCTCAATGCCACTGTCACATTGGCAATCATCACAGTGACTCCCAAATCCTTTGGGTCACCTGG	16	109	1
T00250	GeneExpression	LRP1	NM_002332	13,14	chr12	57554779	120M1201N17M	Plus	TCCAAGACAGTGCTTTGGCCCAATGGGCTAAGCCTGGACATCCCGGCTGGGCGCCTCTACTGGGTGGATGCCTTCTACGACCGCATCGAGACGATACTGCTCAATGGCACAGACCGGAAGATTGTGTATGAAGGTCC	16	107	1
T00251	GeneExpression	LY9	NM_002348	5,6	chr1	160786557	97M1354N35M	Plus	TGGAGAAGCAGTGAAAATCACCCCAACCTCACATGCACAGCCAGCAACCCTGTCAGCAGGAGTTCCCACCAGTTTCTTTCTGAGAACATCTGTTCAGGACCTGAGAGAAACACAAAGCTTTGGATTGGGTTG	16	102	1
T00252	GeneExpression	SH2D1A	NM_002351	2,3	chrX	123499637	38M4351N95M	Plus	GAGTGTCCCAGACAGAAACAGGTTCTTGGAGTGCTGAGACAGCACCTGGGGTACATAAAAGATATTTCCGGAAAATAAAAAATCTCATTTCAGCATTTCAGAAGCCAGATCAAGGCATTGTAATACCTCTGCA	16	103	1
T00253	GeneExpression	M6PR	NM_002355	1,2	chr12	9098925	61M3082N77M	Minus	ATCCCCAGAAGGGTATTCACTGGGGATTCTGAGCTTTGGCTACTCCAGTTTCCCACGACACGATGTTCCCTTTCTACAGCTGCTGGAGGACTGGACTGCTACTACTACTCCTGGCTGTGGCAGTGAGAGAATCCTGGC	16	108	1
T00254	GeneExpression		ENST00000544245		chr12	9098925	61M3100N59M	Minus	ATCCCCAGAAGGGTATTCACTGGGGATTCTGAGCTTTGGCTACTCCAGTTTCCCACGACACCTGCTGGAGGACTGGACTGCTACTACTACTCCTGGCTGTGGCAGTGAGAGAATCCTGGC	16	90	2
T00255	GeneExpression		ENST00000543845		chr12	9098925	61M2663N109M310N77M	Minus	ATCCCCAGAAGGGTATTCACTGGGGATTCTGAGCTTTGGCTACTCCAGTTTCCCACGACACTGTAAAAGACAACTGTACTTATGGGAAGTCTAGAAACCCTTGAGATTTGTGACCTGTAGAGGCCAAAGAGGTTTCAGAAGACTACATCAAGCCATCAAACAGTAAAGAGGATGTTCCCTTTCTACAGCTGCTGGAGGACTGGACTGCTACTACTACTCCTGGCTGTGGCAGTGAGAGAATCCTGGC	16	217	3
T00256	GeneExpression	MAD2L1	NM_002358	1,2	chr4	120986935	98M843N39M	Minus	CGTGCTTTTGTTTGTGTCCCTGGCCATGGCGCTGCAGCTCTCCCGGGAGCAGGGAATCACCCTGCGCGGGAGCGCCGAAATCGTGGCCGAGTTCTTCTCATTCGGCATCAACAGCATTTTATATCAGCGTGGCATAT	16	107	1
T00257	GeneExpression	MIF	NM_002415	1,2	chr22	24236706	64M189N80M	Plus	GCCGGACGGGTTCCTCTCCGAGCTCACCCAGCAGCTGGCGCAGGCCACCGGCAAGCCCCCCCAGTACATCGCGGTGCACGTGGTCCCGGACCAGCTCATGGCCTTCGGCGGCTCCAGCGAGCCGTGCGCGCTCTGCAGCCTGCA	16	114	1
T00258	GeneExpression		NR_038911		chr22	24236706	333M	Plus	GCCGGACGGGTTCCTCTCCGAGCTCACCCAGCAGCTGGCGCAGGCCACCGGCAAGCCCCCCCAGGTTTGCCGGGAGGGGACAGGAAGAGGGGGGTGCCCACCGGACGAGGGGTTCCGCGCTGGGAGCTGGGGAGGCGACTCCTGAACGGAGCTGGGGGGCGGGGCGGGGGGAGGACGGTGGCTCGGGCCCGAAGTGGACGTTCGGGGCCCGACGAGGTCGCTGGGGCGGGCTGACCGCGCCCTTTCCTCGCAGTACATCGCGGTGCACGTGGTCCCGGACCAGCTCATGGCCTTCGGCGGCTCCAGCGAGCCGTGCGCGCTCTGCAGCCTGCA	16	303	2
T00259	GeneExpression	CXCL9	NM_002416	2,3	chr4	76926012	97M1254N35M	Minus	CCTGCATCAGCACCAACCAAGGGACTATCCACCTACAATCCTTGAAAGACCTTAAACAATTTGCCCCAAGCCCTTCCTGCGAGAAAATTGAAATCATTGCTACACTGAAGAATGGAGTTCAAACATGTCTAA	16	102	1
T00260	GeneExpression	MKI67	NM_002417	6,7	chr10	129914166	30M483N106M	Minus	TCTCAAGATCTAGCTTCTCTTCTGACCCTGATGAGAAAGCTCAAGATTCCAAGGCCTATTCAAAAATCACTGAAGGAAAAGTTTCAGGAAATCCTCAGGTACATATCAAGAATGTCAAAGAAGACAGTACCGCAGA	16	106	1
T00261	GeneExpression	MRC1	NM_002438	2,3	chr10	18112393	53M4049N83M	Plus	CAGGTGGAAGATCTATGGAACCACAGACAATCTGTGCTCCAGAGGTTATGAAGCCATGTATACGCTACTAGGCAATGCCAATGGAGCAACCTGTGCATTCCCGTTCAAGTTTGAAAACAAGTGGTACGCAGATTGC	16	106	1
T00262	None		NM_002438_1		chr10	17865422	53M4066N83M	Plus	CAGGTGGAAGATCTATGGAACCACAGACAATCTGTGCTCCAGAGGTTATGAAGCCATGTATACGCTACTAGGCAATGCCAATGGAGCAACCTGTGCATTCCCGTTCAAGTTTGAAAACAAGTGGTACGCAGATTGC	16	106	-1
T00263	GeneExpression	IRF4	NM_002460	6,7	chr6	398835	101M2488N39M	Plus	GGTGACAGGAACCTTTTATGCTTGTGCCCCACCTGAGTCCCAGGCTCCCGGAGTCCCCACAGAGCCAAGCATAAGGTCTGCCGAAGCCTTGGCGTTCTCAGACTGCCGGCTGCACATCTGCCTGTACTACCGGGAAATCC	16	110	1
T00264	GeneExpression	MYC	NM_002467	1,2	chr8	128748809	61M1624N79M	Plus	CTGAAAGGCTCTCCTTGCAGCTGCTTAGACGCTGGATTTTTTTCGGGTAGTGGAAAACCAGCAGCCTCCCGCGACGATGCCCCTCAACGTTAGCTTCACCAACAGGAACTATGACCTCGACTACGACTCGGTGCAGCCGT	16	110	1
T00265	GeneExpression		ENST00000517291		chr8	128748809	61M1627N76M	Plus	CTGAAAGGCTCTCCTTGCAGCTGCTTAGACGCTGGATTTTTTTCGGGTAGTGGAAAACCAGCCTCCCGCGACGATGCCCCTCAACGTTAGCTTCACCAACAGGAACTATGACCTCGACTACGACTCGGTGCAGCCGT	16	107	2
T00266	GeneExpression		ENST00000520751		chr8	128748809	61M1668N35M	Plus	CTGAAAGGCTCTCCTTGCAGCTGCTTAGACGCTGGATTTTTTTCGGGTAGTGGAAAACCAGGAACTATGACCTCGACTACGACTCGGTGCAGCCGT	16	66	3
T00267	GeneExpression	NT5E	NM_002526	3,4	chr6	86181074	70M13809N63M	Plus	CTCATCGCTCAGAAAGTGAGGGGTGTGGACGTCGTGGTGGGAGGACACTCCAACACATTTCTTTACACAGGCAATCCACCTTCCAAAGAGGTGCCTGCTGGGAAGTACCCATTCATAGTCACTTCTGATGATG	16	103	1
T00268	GeneExpression	PGF	NM_002632	3,4	chr14	75415267	111M773N20M	Minus	GTGGAGCACATGTTCAGCCCATCCTGTGTCTCCCTGCTGCGCTGCACCGGCTGCTGCGGCGATGAGAATCTGCACTGTGTGCCGGTGGAGACGGCCAATGTCACCATGCAGCTCCTAAAGATCCGTTCTGG	16	101	1
T00269	GeneExpression	SRGN	NM_002727	2,3	chr10	70856889	99M6639N30M	Plus	CAGTAATTCTGCAAACTGCCTTGAAGAAAAAGGACCAATGTTCGAACTACTTCCAGGTGAATCCAACAAGATCCCCCGTCTGAGGACTGACCTTTTTCCAAAGACGAGAATCCAGGACTTGAATCGTAT	16	99	1
T00270	GeneExpression	MAPK1	NM_002745	8,9	chr22	22118422	24M4954N108M	Minus	GGATACAGATCTTAAATTTGTCAGGACAAGGGCTCAGAGGACTGGACGTGCTCAGACATCGGTGTTCTTCTTCCCAGTTCTTGACCCCTGGTCCTGTCTCCAGCCCGTCTTGGCTTATCCACTTTGACTCCT	16	102	1
T00271	GeneExpression	PSMB9	NM_002800	4,5	chr6	32825821	91M229N47M	Plus	AAATGTGGTGAGAAATATCAGCTATAAATATCGAGAGGACTTGTCTGCACATCTCATGGTAGCTGGCTGGGACCAACGTGAAGGAGGTCAGGTATATGGAACCCTGGGAGGAATGCTGACTCGACAGCCTTTTGCCAT	16	108	1
T00272	GeneExpression	PTK7	NM_002821	8,9	chr6	43106638	83M153N57M	Plus	AACCCGGCTACTTGGATTGCCTGACCCAGGCCACACCAAAACCTACAGTTGTCTGGTACAGAAACCAGATGCTCATCTCAGAGGACTCACGGTTCGAGGTCTTCAAGAATGGGACCTTGCGCATCAACAGCGTGGAGGTG	16	110	1
T00273	GeneExpression	PTPN11	NM_002834	9,10	chr12	112915758	62M4058N76M	Plus	TGGTGTTCCAAGAAAACTCCCGAGTGATTGTCATGACAACGAAAGAAGTGGAGAGAGGAAAGAGTAAATGTGTCAAATACTGGCCTGATGAGTATGCTCTAAAAGAATATGGCGTCATGCGTGTTAGGAACGTCAAAG	16	108	1
T00274	None		ENST00000483126		chr3	106824372	138M	Minus	TGGTGTTCCAAGAAAACTCCCAGGTGATTGTCATGACAACGAAAGAAGTGGAGAGAGGAAAGAGTAAATGTGTCAAATACTGGCCCGATGAGTATGCTCTAAAAGAATATGGCATCGTGCATGTTAGGAACGTCAAAG	16	108	-1
T00275	None		ENST00000511359		chr5	23304283	138M	Minus	TGGTGTTCCAAGAAAACTCCCGAGTGATTGTCATGACAACAAAAGAAGTGGATAGAGGAAAGAGTAAATGTGTCAAATACTGGCCTGATGAGTATGCTTTAAAAGAATATGGCGTCATGCGTGTTAGGAACGTCAAAG	16	108	-2
T00276	GeneExpression	PTPRC	NM_002838	6,7	chr1	198671558	102M767N36M	Plus	ACCCAGTTTCCCCATTGACAACCACCCTCAGCCTTGCACACCACAGCTCTGCTGCCTTACCTGCACGCACCTCCAACACCACCATCACAGCGAACACCTCAGATGCCTACCTTAATGCCTCTGAAACAACCACTCTGA	16	108	1
T00277	GeneExpression	PYGL	NM_002863	4,5	chr14	51390762	85M7572N57M	Minus	GGCAACCCTGGGACTTGCAGCCTATGGATACGGCATTCGGTATGAATATGGGATTTTCAATCAGAAGATCCGAGATGGATGGCAGGTAGAAGAAGCAGATGATTGGCTCAGATATGGAAACCCTTGGGAGAAGTCCCGCCCA	16	112	1
T00278	GeneExpression	S100A8	NM_002964	2,3	chr1	153362682	88M151N38M	Minus	GTACTCCCTGATAAAGGGGAATTTCCATGCCGTCTACAGGGATGACCTGAAGAAATTGCTAGAGACCGAGTGTCCTCAGTATATCAGGAAAAAGGGTGCAGACGTCTGGTTCAAAGAGTTGGATAT	16	96	1
T00279	GeneExpression	S100A9	NM_002965	2,3	chr1	153330875	35M2210N102M	Plus	AGCTGGTGCGAAAAGATCTGCAAAATTTTCTCAAGAAGGAGAATAAGAATGAAAAGGTCATAGAACACATCATGGAGGACCTGGACACAAATGCAGACAAGCAGCTGAGCTTCGAGGAGTTCATCATGCTGATGGCG	16	107	1
T00280	GeneExpression	CCL2	NM_002982	2,3	chr17	32583318	41M382N94M	Plus	AGAAGAATCACCAGCAGCAAGTGTCCCAAAGAAGCTGTGATCTTCAAGACCATTGTGGCCAAGGAGATCTGTGCTGACCCCAAGCAGAAGTGGGTTCAGGATTCCATGGACCACCTGGACAAGCAAACCCAAACT	16	105	1
T00281	GeneExpression	CCL3	NM_002983	2,3	chr17	34416041	68M420N68M	Minus	CAGATTCCACAGAATTTCATAGCTGACTACTTTGAGACGAGCAGCCAGTGCTCCAAGCCCGGTGTCATCTTCCTAACCAAGCGAAGCCGGCAGGTCTGTGCTGACCCCAGTGAGGAGTGGGTCCAGAAATATGTCA	16	106	1
T00282	None		NM_001001437_1		chr17	34522708	68M421N68M	Minus	CAGATTCCACAGAATTTCATAGCTGACTACTTTGAGACGAGCAGCCAGTGCTCCAAGCCCAGTGTCATCTTCCTAACCAAGAGAGGCCGGCAGGTCTGTGCTGACCCCAGTGAGGAGTGGGTCCAGAAATATGTCA	16	106	-1
T00283	None		NM_001001437		chr17	34624282	68M421N68M	Minus	CAGATTCCACAGAATTTCATAGCTGACTACTTTGAGACGAGCAGCCAGTGCTCCAAGCCCAGTGTCATCTTCCTAACCAAGAGAGGCCGGCAGGTCTGTGCTGACCCCAGTGAGGAGTGGGTCCAGAAATATGTCA	16	106	-2
T00284	GeneExpression	CCL4	NM_002984	1,2	chr17	34431325	50M546N80M	Plus	TCTCCTCATGCTAGTAGCTGCCTTCTGCTCTCCAGCGCTCTCAGCACCAATGGGCTCAGACCCTCCCACCGCCTGCTGCTTTTCTTACACTGCGAGGAAGCTTCCTCGCAACTTTGTGGTAGATTACTAT	16	100	1
T00285	None		NM_207007		chr17	34538570	50M558N80M	Plus	TCTCCTCATGCTAGTAGCTGCCTTCTGCTCTCTAGCACTCTCAGCACCAATGGGCTCAGACCCTCCCACCGCCTGCTGCTTTTCTTACACCGCGAGGAAGCTTCCTCGCAACTTTGTGGTAGATTACTAT	16	100	-1
T00286	None		NM_001001435_1		chr17	34640136	50M558N80M	Plus	TCTCCTCATGCTAGTAGCTGCCTTCTGCTCTCTAGCACTCTCAGCACCAATGGGCTCAGACCCTCCCACCGCCTGCTGCTTTTCTTACACCGCGAGGAAGCTTCCTCGCAACTTTGTGGTAGATTACTAT	16	100	-2
T00287	GeneExpression	CCL5	NM_002985	1,2	chr17	34205554	50M1590N90M	Minus	TGTCATCCTCATTGCTACTGCCCTCTGCGCTCCTGCATCTGCCTCCCCATATTCCTCGGACACCACACCCTGCTGCTTTGCCTACATTGCCCGCCCACTGCCCCGTGCCCACATCAAGGAGTATTTCTACACCAGTGGCA	16	110	1
T00288	GeneExpression	CCL17	NM_002987	3,4	chr16	57449066	45M566N92M	Plus	GACGTGGTACCAGACATCTGAGGACTGCTCCAGGGATGCCATCGTTTTTGTAACTGTGCAGGGCAGGGCCATCTGTTCGGACCCCAACAACAAGAGAGTGAAGAATGCAGTTAAATACCTGCAAAGCCTTGAGAGGT	16	107	1
T00289	GeneExpression	CCL18	NM_002988	2,3	chr17	34397862	57M392N72M	Plus	AAAGTTCATAGTTGACTATTCTGAAACCAGCCCCCAGTGCCCCAAGCCAGGTGTCATCCTCCTAACCAAGAGAGGCCGGCAGATCTGTGCTGACCCCAATAAGAAGTGGGTCCAGAAATACATCAGCGA	16	99	1
T00290	None		NM_002983		chr17	34416037	57M420N72M	Minus	AAAGTTCATAGTTGACTACTTTGAGACGAGCAGCCAGTGCTCCAAGCCCGGTGTCATCTTCCTAACCAAGCGAAGCCGGCAGGTCTGTGCTGACCCCAGTGAGGAGTGGGTCCAGAAATACATCAGCGA	16	99	-1
T00291	GeneExpression	CCL21	NM_002989	3,4	chr9	34709326	39M72N99M	Minus	GACTGGCAAGAAAGGAAAGGGCTCCAAAGGCTGCAAGAGGACTGAGCGGTCACAGACCCCTAAAGGGCCATAGCCCAGTGAGCAGCCTGGAGCCCTGGAGACCCCACCAGCCTCACCAGCGCTTGAAGCCTGAACCCA	16	108	1
T00292	GeneExpression		ENST00000378792		chr9	34709326	210M	Minus	GACTGGCAAGAAAGGAAAGGGCTCCAAAGGCTGCAAGAGGTGAGGAATCTGAGGGATGTGGGTAAAGGGGAGCCTCAGTCAGCCCCTCACACCCCTCTTCTGCCCTCACAGGACTGAGCGGTCACAGACCCCTAAAGGGCCATAGCCCAGTGAGCAGCCTGGAGCCCTGGAGACCCCACCAGCCTCACCAGCGCTTGAAGCCTGAACCCA	16	180	2
T00293	GeneExpression	CCL22	NM_002990	1,2	chr16	57392758	44M1547N93M	Plus	TGTCCTCGTCCTCCTTGCTGTGGCGCTTCAAGCAACTGAGGCAGGCCCCTACGGCGCCAACATGGAAGACAGCGTCTGCTGCCGTGATTACGTCCGTTACCGTCTGCCCCTGCGCGTGGTGAAACACTTCTACTGGA	16	107	1
T00294	GeneExpression	CX3CL1	NM_002996	2,3	chr16	57413583	84M2275N55M	Plus	CAGCAAGATGACATCAAAGATACCTGTAGCTTTGCTCATCCACTATCAACAGAACCAGGCATCATGCGGCAAACGCGCAATCATCTTGGAGACGAGACAGCACAGGCTGTTCTGTGCCGACCCGAAGGAGCAATGGGTC	16	109	1
T00295	GeneExpression	SNAI2	NM_003068	2,3	chr8	49831505	94M907N43M	Minus	ATTCGGACCCACACATTACCTTGTGTTTGCAAGATCTGCGGCAAGGCGTTTTCCAGACCCTGGTTGCTTCAAGGACACATTAGAACTCACACGGGGGAGAAGCCTTTTTCTTGCCCTCACTGCAACAGAGCATTTGC	16	107	1
T00296	GeneExpression	SSX2	NM_003147	3,4	chrX	52733571	75M535N72M	Minus	GGGAAAAGATGAAAGCCTCGGAGAAAATCTTCTATGTGTATATGAAGAGAAAGTATGAGGCTATGACTAAACTAGGTTTCAAGGCCACCCTCCCACCTTTCATGTGTAATAAACGGGCCGAAGACTTCCAGGGGAATGATTTGGATA	16	117	1
T00297	None		NM_175723		chrX	48053589	75M515N72M	Minus	GGGAAAAGATGAAAGCCTCGGAGAAAATCATCTATGTGTATATGAAGAGAAAGTATGAGGCCATGACTAAACTAGGTTTCAAGGCCACCCTCCCACCTTTCATGCGTAATAAACGGGTCGCAGACTTCCAGGGGAATGATTTGGATA	16	117	-1
T00298	None		NM_021014		chrX	48213458	75M537N72M	Minus	GGGAAAAGATGAAAGTCTCGGAGAAAATCGTCTATGTGTATATGAAGAGAAAGTATGAGGCCATGACTAAACTAGGTTTCAAGGCCATCCTCCCATCTTTCATGCGTAATAAACGGGTCACAGACTTCCAGGGGAATGATTTGGATA	16	117	-2
T00299	None		NM_175698_1		chrX	52782305	75M535N72M	Plus	GGGAAAAGATGAAAGCCTCGGAGAAAATCTTCTATGTGTATATGAAGAGAAAGTATGAGGCTATGACTAAACTAGGTTTCAAGGCCACCCTCCCACCTTTCATGTGTAATAAACGGGCCGAAGACTTCCAGGGGAATGATTTGGATA	16	117	-3
T00300	None		ENST00000451349		chrX	52627584	75M557N72M	Plus	GGGAAAAGATGAAAGCCTCAGAGAAAATCATCCATGTGTATATGAAGAGAAAGTATGAGGCCATGACTAAACAGGGTTTCACGGCTACCATCCCAACTTTCATGGATGACAAAGGGGCCGCAGACTGCCAGGGGAATGATTTGGATA	16	117	-4
T00301	GeneExpression	STAT4	NM_003151	1,2	chr2	192012878	85M2742N53M	Minus	CAGCGGCTTTCTCCTAGGGACTGTGAGGGGCGCTTCTGACTTTGGACTTGAGCACTGCCTGGGACCTGTGCTGAGAGAGCGCTAGCATGTCTCAGTGGAATCAAGTCCAACAGTTAGAAATCAAGTTTTTGGAGCAGG	16	108	1
T00302	GeneExpression	STAT5A	NM_003152	11,12	chr17	40456383	65M100N70M	Plus	ACAACTGCTGCGTGATGGAGTACCACCAAGCCACGGGCACCCTCAGTGCCCACTTCAGGAACATGTCACTGAAGAGGATCAAGCGTGCTGACCGGCGGGGTGCAGAGTCCGTGACAGAGGAGAAGTTCACAGTCC	16	105	1
T00303	GeneExpression	STAT6	NM_003153	1,2	chr12	57502014	70M2829N69M	Minus	AGAGCTACAGACCTATGGGGCCTGGAAGTGCCCGCTGAGAAAGGGAGAAGACAGCAGAGGGGTTGCCGAGGCAACCTCCAAGTCCCAGATCATGTCTCTGTGGGGTCTGGTCTCCAAGATGCCCCCAGAAAAAGTGCAG	16	109	1
T00304	GeneExpression		NM_001178078		chr12	57502014	89M2810N69M	Minus	AGAGCTACAGACCTATGGGGCCTGGAAGTGCCCGCTGAGAAAGGGAGAAGACAGCAGAGGGGTTGCCGAGGTGAGGGGTTGCCTCCGAGGCAACCTCCAAGTCCCAGATCATGTCTCTGTGGGGTCTGGTCTCCAAGATGCCCCCAGAAAAAGTGCAG	16	128	2
T00305	GeneExpression		ENST00000554825		chr12	57502014	70M1018N68M1743N69M	Minus	AGAGCTACAGACCTATGGGGCCTGGAAGTGCCCGCTGAGAAAGGGAGAAGACAGCAGAGGGGTTGCCGAGAGAAAGGCCTATTGGAGGAACCTGAGCAGGAGGGGTAAGGATTCTGCCTTGAGGAGAAAAGAGCTGGGGCAACCTCCAAGTCCCAGATCATGTCTCTGTGGGGTCTGGTCTCCAAGATGCCCCCAGAAAAAGTGCAG	16	177	3
T00306	GeneExpression		ENST00000553275		chr12	57502014	70M1018N170M1641N69M	Minus	AGAGCTACAGACCTATGGGGCCTGGAAGTGCCCGCTGAGAAAGGGAGAAGACAGCAGAGGGGTTGCCGAGAGAAAGGCCTATTGGAGGAACCTGAGCAGGAGGGGTAAGGATTCTGCCTTGAGGAGAAAAGAGCTGGGGTAAGTGGGCACTGGAGGAAAGAGGGGCATGAAGGTCTTGGAGCAGAAACGTCCAGAGAAGGGACCTCTCCATTTTCCATCCCTCTGAGAGGCCTGGGAGAGGCAACCTCCAAGTCCCAGATCATGTCTCTGTGGGGTCTGGTCTCCAAGATGCCCCCAGAAAAAGTGCAG	16	279	4
T00307	GeneExpression	TBP	NM_003194	2,3	chr6	170866082	90M4707N49M	Plus	AAGGGTTTCTGGTTTGCCAAGAAGAAAGTGAACATCATGGATCAGAACAACAGCCTGCCACCTTACGCTCAGGGCTTGGCCTCCCCTCAGGGTGCCATGACTCCCGGAATCCCTATCTTTAGTCCAATGATGCCTTATG	16	109	1
T00308	GeneExpression	TCF7	NM_003202	4,5	chr5	133473774	82M786N71M	Plus	GGTGTCCCCCAACTCTCTCTCTACGAACATTTCAACAGCCCACATCCCACCCCTGCACCTGCGGACATCAGCCAGAAGCAAGTTCACAGGCCTCTGCAGACCCCTGACCTCTCTGGCTTCTACTCCCTGACCTCAGGCAGCATGGGGCAGCTC	16	123	1
T00309	None		NM_000418		chr16	27374267	100M	Plus	GGTGTCCCCCAACTCTCTGAGCCAACCACTGTGCCCCAACCTGAGCCAGAAACCTGGGAGCAGATCCTCCGCCGAAATGTCCTCCAGCATGGGGCAGCTC	16	70	-1
T00310	GeneExpression		ENST00000520652		chr5	133473774	155M713N71M	Plus	GGTGTCCCCCAACTCTCTCTCTACGAACATTTCAACAGCCCACATCCCACCCCTGCACCTGCGGACATCAGCCAGAAGCAAGGTACAAGCCTGGGATGGGGAGGGGCCCAGTGAAACCAGAGCCTAAGGGCCAAGACCCCAGCTTCTGAGACCAGTTCACAGGCCTCTGCAGACCCCTGACCTCTCTGGCTTCTACTCCCTGACCTCAGGCAGCATGGGGCAGCTC	16	196	2
T00311	GeneExpression	TLR3	NM_003265	4,5	chr4	187005217	110M472N23M	Plus	TTTGAGGCGGGTGTTTTTGAACTAGAAGCAATTGTTAACAGCATCAAAAGAAGCAGAAAAATTATTTTTGTTATAACACACCATCTATTAAAAGACCCATTATGCAAAAGATTCAAGGTACATCATGCAGTTC	16	103	1
T00312	GeneExpression	TNFSF4	NM_003326	2,3	chr1	173155909	27M1655N96M	Minus	TTCAAAGTATCAAAGTACAATTTACCGAATATAAGAAGGAGAAAGGTTTCATCCTCACTTCCCAAAAGGAGGATGAAATCATGAAGGTGCAGAACAACTCAGTCATCATCAACTGTGATGGGT	16	93	1
T00313	GeneExpression	TNFRSF4	NM_003327	2,3	chr1	1148379	21M569N95M	Minus	CCTGCACGTGGTGTAACCTCAGAAGTGGGAGTGAGCGGAAGCAGCTGTGCACGGCCACACAGGACACAGTCTGCCGCTGCCGGGCGGGCACCCAGCCCCTGGACAGCTACAAGCCT	16	86	1
T00314	GeneExpression	CXCR4	NM_003467	1,2	chr2	136873370	26M2133N113M	Minus	CAGCGGTTACCATGGAGGGGATCAGTATATACACTTCAGATAACTACACCGAGGAAATGGGCTCAGGGGACTATGACTCCATGAAGGAACCCTGTTTCCGTGAAGAAAATGCTAATTTCAATAAAATCTTCCTGCCCAC	16	109	1
T00315	GeneExpression	IFITM1	NM_003641	1,2	chr11	314334	23M565N108M	Plus	TAGCATTCGCCTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCCTCATGACCATT	16	101	1
T00316	None		ENST00000399815		chr11	308416	23M6483N108M	Plus	TAGCATTCGCCTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCCTCATGACCATT	16	101	-1
T00317	GeneExpression	TP63	NM_003722	1,2	chr3	189349343	24M106162N110M	Plus	CTGCCCTGACCCTTACATCCAGCGTTTCGTAGAAACCCCAGCTCATTTCTCTTGGAAAGAAAGTTATTACCGATCCACCATGTCCCAGAGCACACAGACAAATGAATTCCTCAGTCCAGAGGTTTTCCAGCATA	16	104	1
T00318	GeneExpression	TNFSF14	NM_003807	1,2	chr19	6670114	85M137N56M	Minus	CGAATGAAGCATCCAAGAAGGGAAAGCTGGGGGCTCCCCACTGCACTTGCCACCTGAGTCACATTTTCAGAAGCCTCTGGAAAGTCGTGCACAGCCCAGGAGTGTTGAGCAATTTCGGTTTCCTCTGAGGTTGAAGGACCC	16	111	1
T00319	GeneExpression	TNFSF10	NM_003810	1,2	chr3	172232672	20M8254N117M	Minus	TTACCAACGAGCTGAAGCAGATGCAGGACAAGTACTCCAAAAGTGGCATTGCTTGTTTCTTAAAAGAAGATGACAGTTATTGGGACCCCAATGACGAAGAGAGTATGAACAGCCCCTGCTGGCAAGTCAAGTGGCAA	16	107	1
T00320	GeneExpression	TNFSF9	NM_003811	2,3	chr19	6532801	27M1783N91M	Plus	TGTTTGCGCAGCTGGTGGCCCAAAATGTTCTGCTGATCGATGGGCCCCTGAGCTGGTACAGTGACCCAGGCCTGGCAGGCGTGTCCCTGACGGGGGGCCTGAGCTACAAAGAGGACAC	16	88	1
T00321	GeneExpression	TNFRSF14	NM_003820	5,6	chr1	2492134	20M958N115M	Plus	GAATGTCAGCACCAGACCAAGTGCAGCTGGCTGGTGACGAAGGCCGGAGCTGGGACCAGCAGCTCCCACTGGGTATGGTGGTTTCTCTCAGGGAGCCTCGTCATCGTCATTGTTTGCTCCACAGTTGGCCTAATC	16	105	1
T00322	GeneExpression		ENST00000463471		chr1	2492134	20M779N294M	Plus	GAATGTCAGCACCAGACCAACCGAGCTTGGAAAAGTCAGACAGACCTCTGAGGTCTCATCCTGGAGCTGCCACCAGCCCAGCCTCCCTGGGACCTGTCTTCACTGCCTGGGGCCCTGGGAGCCAGGGAGGCTCCCTGAGGCTGAGTGAACACTGGGCGCTGCACCTGCCTCTCCCACGTCCTCGGCCCCACTCCCGCAGGTGCAGCTGGCTGGTGACGAAGGCCGGAGCTGGGACCAGCAGCTCCCACTGGGTATGGTGGTTTCTCTCAGGGAGCCTCGTCATCGTCATTGTTTGCTCCACAGTTGGCCTAATC	16	284	2
T00323	GeneExpression	NRP1	NM_003873	6,7	chr10	33515119	37M27738N99M	Minus	GACTCCCGGAGAGGATTCCTACCGAGAGTGGATACAGGTAGACTTGGGCCTTCTGCGCTTTGTCACGGCTGTCGGGACACAGGGCGCCATTTCAAAAGAAACCAAGAAGAAATATTATGTCAAGACTTACAAGATC	16	106	1
T00324	GeneExpression	SKAP2	NM_003930	7,8	chr7	26765566	94M895N40M	Minus	TGGCTACAGTGTCAGAATGAATAACACTCTAAGAAAGGATGGAAAGAAAGATTGCTGTTTTGAAATCTCTGCTCCTGATAAACGTATATATCAGTTTACAGCAGCTTCTCCCAAAGATGCTGAAGAATGGGTAC	16	104	1
T00325	GeneExpression	FCGR2B	NM_004001	5,6	chr1	161643753	111M1183N31M	Plus	CCAGCTCTTCACCGATGGGGATCATTGTGGCTGTGGTCACTGGGATTGCTGTAGCGGCCATTGTTGCTGCTGTAGTGGCCTTGATCTACTGCAGGAAAAAGCGGATTTCAGCTCTCCCAGGATACCCTGAGTGCAGGGAAAT	16	112	1
T00326	GeneExpression	CTSS	NM_004079	2,3	chr1	150730369	47M6657N88M	Minus	ACTGGCATCTCTGGAAGAAAACCTATGGCAAACAATACAAGGAAAAGAATGAAGAAGCAGTACGACGTCTCATCTGGGAAAAGAATCTAAAGTTTGTGATGCTTCACAACCTGGAGCATTCAATGGGAATGCACT	16	105	1
T00327	GeneExpression	FCER1G	NM_004106	1,2	chr1	161185102	59M2615N79M	Plus	CCAGCCCAAGATGATTCCAGCAGTGGTCTTGCTCTTACTCCTTTTGGTTGAACAAGCAGCGGCCCTGGGAGAGCCTCAGCTCTGCTATATCCTGGATGCCATCCTGTTTCTGTATGGAATTGTCCTCACCCTCCTCTA	16	108	1
T00328	GeneExpression	GZMB	NM_004131	4,5	chr14	25100384	101M643N37M	Minus	TGCAGGAAGATCGAAAGTGCGAATCTGACTTACGCCATTATTACGACAGTACCATTGAGTTGTGCGTGGGGGACCCAGAGATTAAAAAGACTTCCTTTAAGGGGGACTCTGGAGGCCCTCTTGTGTGTAACAAGGTGG	16	108	1
T00329	GeneExpression	SDHA	NM_004168	11,12	chr5	240546	46M10515N84M	Plus	TGATGGAAGCATAAGAACATCGGAACTGCGACTCAGCATGCAGAAGTCAATGCAAAATCATGCTGCCGTGTTCCGTGTGGGAAGCGTGTTGCAAGAAGGTTGTGGGAAAATCAGCAAGCTCTATGGAGAC	16	100	1
T00330	None		ENST00000515467		chr5	1576687	46M12591N84M	Minus	TGATGGAAGCATAAGAACATGAGAACTGCGACTCAGCATGCAGAAGTAAATGCAAAATCATGCTGCCGTGTTCCGTGTGGGAAGCGTGTTGCAAGAAGGTTGTGGGAAAATCAGCAAGCTCTATGGAGAC	16	100	-1
T00331	GeneExpression	TNFRSF18	NM_004195	2,3	chr1	1139844	116M883N23M	Minus	GTGCTGTTCCGAGTGGGACTGCATGTGTGTCCAGCCTGAATTCCACTGCGGAGACCCTTGCTGCACGACCTGCCGGCACCACCCTTGTCCCCCAGGCCAGGGGGTACAGTCCCAGGGGAAATTCAGTTTTGGCTTCCAG	16	109	1
T00332	GeneExpression	CD83	NM_004233	3,4	chr6	14131884	96M1900N35M	Plus	ACACTACCAGCTGCAACTCGGGGACATACAGGTGCACTCTGCAGGACCCGGATGGGCAGAGAAACCTAAGTGGCAAGGTGATCTTGAGAGTGACAGGATGCCCTGCACAGCGTAAAGAAGAGACTTTTAAG	16	101	1
T00333	GeneExpression	CD163	NM_004244	8,9	chr12	7639501	52M372N82M	Minus	CTAGGTGCTTCATTATGTCCTTCAGAGCAAGTGGCCTCTGTAATCTGCTCAGGAAACCAGTCCCAAACACTGTCCTCGTGCAATTCATCGTCTTTGGGCCCAACAAGGCCTACCATTCCAGAAGAAAGTGCTGT	16	104	1
T00334	GeneExpression	BST2	NM_004335	1,2	chr19	17515204	92M853N43M	Minus	ATGTCACCCATCTCCTGCAACAAGAGCTGACCGAGGCCCAGAAGGGCTTTCAGGATGTGGAGGCCCAGGCCGCCACCTGCAACCACACTGTGATGGCCCTAATGGCTTCCCTGGATGCAGAGAAGGCCCAAGGAC	16	105	1
T00335	GeneExpression	BUB1	NM_004336	7,8	chr2	111425197	47M91N86M	Minus	GAGCTTTCTGGAGTGATATCTTCAGCTTGTGATAAAGAGTCAAATATGGAACGAAGAGTGATCACGATTTCTAAATCAGAATATTCTGTGCACTCATCTTTGGCATCCAAAGTTGATGTTGAGCAGGTTGTTA	16	103	1
T00336	GeneExpression	CCR6	NM_004367	2,3	chr6	167549573	59M96N64M	Plus	GAACCATACACTCCTTTTTCTACAACCAGCTTGCATTTTTTCTGCCCACAATGAGCGGGGAATCAATGAATTTCAGCGATGTTTTCGACTCCAGTGAAGATTATTTTGTGTCAGTCAATACTT	16	93	1
T00337	GeneExpression	EGR3	NM_004430	1,2	chr8	22548977	117M1308N19M	Minus	TGAGCAGTTTGCTAAACCAACTGCCTGACAATCTGTACCCCGAGGAGATCCCCAGCGCGCTCAACCTCTTCTCCGGCAGCAGCGACTCGGTAGTCCATTACAATCAGATGGCTACAGAGAATGTAATGGACATCGG	16	106	1
T00338	GeneExpression		ENST00000519492		chr8	22548977	117M436N53M819N19M	Minus	TGAGCAGTTTGCTAAACCAACTGCCTGACAATCTGTACCCCGAGGAGATCCCCAGCGCGCTCAACCTCTTCTCCGGCAGCAGCGACTCGGTAGTCCATTACAATCAGATGGCTACAGCCTCCCACCCGGGATGGAGCCATGTGCGGCGTGGAGTCCCCGCGGTGGGAGAGAGAATGTAATGGACATCGG	16	159	2
T00339	GeneExpression	MMP2	NM_004530	5,6	chr16	55519636	54M2765N85M	Plus	CCACCACCTACAACTTTGAGAAGGATGGCAAGTACGGCTTCTGTCCCCATGAAGCCCTGTTCACCATGGGCGGCAACGCTGAAGGACAGCCCTGCAAGTTTCCATTCCGCTTCCAGGGCACATCCTATGACAGCTGCAC	16	109	1
T00340	GeneExpression	CCL20	NM_004591	3,4	chr2	228681043	58M677N79M	Plus	TGTCTGTGTGCGCAAATCCAAAACAGACTTGGGTGAAATATATTGTGCGTCTCCTCAGTAAAAAAGTCAAGAACATGTAAAAACTGTGGCTTTTCTGGAATGGAATTGGACATAGCCCAAGAACAGAAAGAACCTTG	16	107	1
T00341	GeneExpression	CCNB2	NM_004701	6,7	chr15	59409078	48M301N92M	Plus	CGACCCTTGCCACTACACTTCTTAAGGCGAGCATCAAAAGCCGGGGAGGTTGATGTTGAACAGCACACTTTAGCCAAGTATTTGATGGAGCTGACTCTCATCGACTATGATATGGTGCATTATCATCCTTCTAAGGTAGC	16	110	1
T00342	None		ENST00000399411		chr7	7949198	140M	Minus	CGACCCTTGCCACTACACTTCTTAAGGCAAGCATCAAAAGCCGGGAAGGCTGATGTTGAACAGCACACTTTAGCCAAATATTTGATGGAGCTGACTCTCATTGACTACGATATGATGCATTATCATCCTTCTAAGGTAGC	16	110	-1
T00343	GeneExpression	GRAP2	NM_004810	2,3	chr22	40343115	74M8634N61M	Plus	AAGCTGTTGCCAAGTTTGATTTCACTGCTTCAGGTGAGGATGAACTGAGCTTTCACACTGGAGATGTTTTGAAGATTTTAAGTAACCAAGAGGAGTGGTTTAAGGCGGAGCTTGGGAGCCAGGAAGGATATGTGC	16	105	1
T00344	GeneExpression	NCR1	NM_004829	6,7	chr19	55423554	33M471N105M	Plus	ACCTTTTAACCACAGAGACGGGACTCCAGAAAGACCATGCCCTCTGGGATCACACTGCCCAGAATCTCCTTCGGATGGGCCTGGCCTTTCTAGTCCTGGTGGCTCTAGTGTGGTTCCTGGTTGAAGACTGGCTCAGCA	16	108	1
T00345	GeneExpression	MTOR	NM_004958	44,45	chr1	11187186	117M479N16M	Minus	GCATCTCGTTTGTACTTTGGGGAAAGGAACGTGAAAGGCATGTTTGAGGTGCTGGAGCCCTTGCATGCTATGATGGAACGGGGCCCCCAGACTCTGAAGGAAACATCCTTTAATCAGGCCTATGGTCGAGATT	16	103	1
T00346	GeneExpression	MAGEA1	NM_004988	1,2	chrX	152483162	76M2811N62M	Minus	AAGCGAGGTTTCCATTCTGAGGGACGGCGTAGAGTTCGGCCGAAGGAACCTGACCCAGGCTCTGTGAGGAGGCAAGGTTTTCAGGGGACAGGCCAACCCAGAGGACAGGATTCCCTGGAGGCCACAGAGGAGCACCAA	16	108	1
T00347	GeneExpression	MMP9	NM_004994	7,8	chr20	44640918	35M113N105M	Plus	CAGCGACAAGAAGTGGGGCTTCTGCCCGGACCAAGGATACAGTTTGTTCCTCGTGGCGGCGCATGAGTTCGGCCACGCGCTGGGCTTAGATCATTCCTCAGTGCCGGAGGCGCTCATGTACCCTATGTACCGCTTCACTG	16	110	1
T00348	GeneExpression	PDCD1	NM_005018	1,2	chr2	242795018	17M5782N115M	Minus	GCCAGGATGGTTCTTAGACTCCCCAGACAGGCCCTGGAACCCCCCCACCTTCTCCCCAGCCCTGCTCGTGGTGACCGAAGGGGACAACGCCACCTTCACCTGCAGCTTCTCCAACACATCGGAGAGCTTCGT	16	102	1
T00349	GeneExpression	PIK3CD	NM_005026	14,15	chr1	9781256	51M195N91M	Plus	CCCCGATTGCCACGTAGGCTCCTTCGCCATCAAGTCGCTGCGGAAACTGACGGACGATGAGCTGTTCCAGTACCTGCTGCAGCTGGTGCAGGTGCTCAAGTACGAGTCCTACCTGGACTGCGAGCTGACCAAATTCCTGCTG	16	112	1
T00350	GeneExpression	PRF1	NM_005041	2,3	chr10	72358819	18M1182N119M	Minus	GGAGTGCCGCTTCTACAGTTTCCATGTGGTACACACTCCCCCGCTGCACCCTGACTTCAAGAGGGCCCTCGGGGACCTGCCCCACCACTTCAACGCCTCCACCCAGCCCGCCTACCTCAGGCTTATCTCCAACTACG	16	107	1
T00351	GeneExpression	RORC	NM_005060	8,9	chr1	151785494	97M181N40M	Minus	GTGGTGCTGGTTAGGATGTGCCGGGCCTACAATGCTGACAACCGCACGGTCTTTTTTGAAGGCAAATACGGTGGCATGGAGCTGTTCCGAGCCTTGGGCTGCAGCGAGCTCATCAGCTCCATCTTTGACTTCTCCCA	16	107	1
T00352	GeneExpression		ENST00000480719		chr1	151785494	318M	Minus	GTGGTGCTGGTTAGGATGTGCCGGGCCTACAATGCTGACAACCGCACGGTCTTTTTTGAAGGCAAATACGGTGGCATGGAGCTGTTCCGAGCCTTGGGTGAGGGGCAGGGAGAAATGAGAGGGAAGATTCTGATGCCAACCCCAGGCAAAGCTTTGTGACCCAGGGCACCCTCTTTTCAGGGCGAATTGCCCCCTCTGCTCTAAACACAATAAGGGCGGTGTCCTCGGGCACCATCGCTCCAGCCACTCTCTCACTTTTCTCATTTCCACTCCATCAGGCTGCAGCGAGCTCATCAGCTCCATCTTTGACTTCTCCCA	16	288	2
T00353	GeneExpression	TNFSF18	NM_005092	1,2	chr1	173013090	111M6771N20M	Minus	ACTCAAGGAGCTCAGAGATCATCCTGGAAGCTGTGGCTCTTTTGCTCAATAGTTATGTTGCTATTTCTTTGCTCCTTCAGTTGGCTAATCTTTATTTTTCTCCAATTAGAGACTGCTAAGGAGCCCTGTAT	16	101	1
T00354	GeneExpression	ISG15	NM_005101	1,2	chr1	948897	60M407N78M	Plus	CTCATCTTTGCCAGTACAGGAGCTTGTGCCGTGGCCCACAGCCCACAGCCCACAGCCATGGGCTGGGACCTGACGGTGAAGATGCTGGCGGGCAACGAATTCCAGGTGTCCCTGAGCAGCTCCATGTCGGTGTCAGAG	16	108	1
T00355	GeneExpression	CD80	NM_005191	2,3	chr3	119263638	54M12761N77M	Minus	ACCTCAATTTCTTTCAGCTCTTGGTGCTGGCTGGTCTTTCTCACTTCTGTTCAGGTGTTATCCACGTGACCAAGGAAGTGAAAGAAGTGGCAACGCTGTCCTGTGGTCACAATGTTTCTGTTGAAGAGCTG	16	101	1
T00356	GeneExpression	CDKN3	NM_005192	5,6	chr14	54878313	112M4192N19M	Plus	TCACCCATCATCATCCAATCGCAGATGGAGGGACTCCTGACATAGCCAGCTGCTGTGAAATAATGGAAGAGCTTACAACCTGCCTTAAAAATTACCGAAAAACCTTAATACACTGCTATGGAGGACTTGGG	16	101	1
T00357	GeneExpression	CSF1R	NM_005211	12,13	chr5	149441122	100M127N37M	Minus	ATCATCGAGAGCTATGAGGGCAACAGTTATACTTTCATCGACCCCACGCAGCTGCCTTACAACGAGAAGTGGGAGTTCCCCCGGAACAACCTGCAGTTTGGTAAGACCCTCGGAGCTGGAGCCTTTGGGAAGGTGGT	16	107	1
T00358	GeneExpression		ENST00000513609		chr5	149441122	264M	Minus	ATCATCGAGAGCTATGAGGGCAACAGTTATACTTTCATCGACCCCACGCAGCTGCCTTACAACGAGAAGTGGGAGTTCCCCCGGAACAACCTGCAGTTTGGTGAGATGGCAGCTCATCACTCCACAGCTTCCTATCACAGGGCCTGTGGGGGTTGCAGGGAGCCCATGGGCCCTTGGACAGAGGCCCTTTGGTGCCCAGGGACTTAAGGGACCTGTGTGCGTGGCAGGTAAGACCCTCGGAGCTGGAGCCTTTGGGAAGGTGGT	16	234	2
T00359	GeneExpression	CTLA4	NM_005214	2,3	chr2	204735613	44M444N92M	Plus	ATACTACCTGGGCATAGGCAACGGAACCCAGATTTATGTAATTGATCCAGAACCGTGCCCAGATTCTGACTTCCTCCTCTGGATCCTTGCAGCAGTTAGTTCGGGGTTGTTTTTTTATAGCTTTCTCCTCACAGCT	16	106	1
T00360	GeneExpression	EFNA4	NM_005227	3,4	chr1	155039893	24M1412N108M	Plus	TGTCTGTCTGCTGCAAGGAGAGGAAGTCTGAGTCAGCCCATCCTGTTGGGAGCCCTGGAGAGAGTGGCACATCAGGGTGGCGAGGGGGGGACACTCCCAGCCCCCTCTGTCTCTTGCTATTACTGCTGCTTC	16	102	1
T00361	GeneExpression	EGFR	NM_005228	24,25	chr7	55268057	50M774N84M	Plus	TCGAATTCTCCAAAATGGCCCGAGACCCCCAGCGCTACCTTGTCATTCAGGGGGATGAAAGAATGCATTTGCCAAGTCCTACAGACTCCAACTTCTACCGTGCCCTGATGGATGAAGAAGACATGGACGACGTG	16	104	1
T00362	GeneExpression	MAGEA3	NM_005362	1,2	chrX	151936320	74M1785N58M	Minus	TTCTCGCCCTGAGCAACGAGCGACGGCCTGACGTCGGCGGAGGGAAGCCGGCCCAGGCTCGGTGAGGAGGCAAGGTTCTGAGGGGACAGGCTGACCTGGAGGACCAGAGGCCCCCGGAGGAGCACTGAAGGA	16	102	1
T00363	None		ENST00000329342		chrX	151867234	74M1792N58M	Plus	TTCTCGCCCTGAGCAACGAGCGACGGCCTGACGTCGGCGGAGGGAAGCCGGCCCAGGCTCGGTGAGGAGGCAAGGTTCTGAGGGGACAGGCTGACCTGGAGGACCAGAGGCCCCCGGAGGAGCACTGAAGGA	16	102	-1
T00364	None		ENST00000492402		chrX	151883105	67M1274N120M819N58M	Plus	TTCTCGCCCTGAGCAACGGCCTGACGTCGGCGGAGGGAAGCAGGCGCAGGCTCCGTGAGGAGGCAAGATCTCAGGGAGTTGATGACCTTGTTTTCAGAAGGTGACTCAGGTCAACACAGGGGCCCCCATCTGGTCGACAGATGCAGTGGTTCTAGGATCTGCCAAGCATCCAGGTGGAGAGCCTGAGGTTCTGAGGGGGACAGGCTGACAAGTAGGACCCGAGGCACTGGAGGAGCACTGAAGGA	16	215	-2
T00365	None		ENST00000370293		chrX	151883105	67M2213N58M	Plus	TTCTCGCCCTGAGCAACGGCCTGACGTCGGCGGAGGGAAGCAGGCGCAGGCTCCGTGAGGAGGCAAGGTTCTGAGGGGGACAGGCTGACAAGTAGGACCCGAGGCACTGGAGGAGCACTGAAGGA	16	95	-3
T00366	None		ENST00000423993		chrX	151883105	67M1274N120M571N98M150N58M	Plus	TTCTCGCCCTGAGCAACGGCCTGACGTCGGCGGAGGGAAGCAGGCGCAGGCTCCGTGAGGAGGCAAGATCTCAGGGAGTTGATGACCTTGTTTTCAGAAGGTGACTCAGGTCAACACAGGGGCCCCCATCTGGTCGACAGATGCAGTGGTTCTAGGATCTGCCAAGCATCCAGGTGGAGAGCCTGAGGAATCAGGAGCTCCAGGAACCAGGCAGTGAGGCCTTGGTCTGAGTCAGTGTCCTCAGGTCACAGAGCAGAGGGGACGCAGACAGTGCCAACACTGAAGGTTCTGAGGGGGACAGGCTGACAAGTAGGACCCGAGGCACTGGAGGAGCACTGAAGGA	16	313	-4
T00367	GeneExpression	MAGEA12	NM_005367	1,2	chrX	151900812	67M2228N64M	Minus	TTCTCGCCCTGAGCAACGGCCTGACGTCGGTGGAGGGAAGCAGGCGCAGGCTCCGTGAGGAGGCAAGGTTCTGAGGAGACAGGCCCCGGAGCAGCACTAGCTCCTGCCCACACTCCTACCTGCTGCCCTGA	16	101	1
T00368	GeneExpression		NM_001166387		chrX	151900812	67M1289N106M833N64M	Minus	TTCTCGCCCTGAGCAACGGCCTGACGTCGGTGGAGGGAAGCAGGCGCAGGCTCCGTGAGGAGGCAAGATCTCAGGGAGTTGAGGACCTTTTCTTCAGAGGGTGACTCAGGTCAACACAGGGGCCCCCATGTAGTCGACAGACACAGTGGTCCTAAGATCTACCAAGCATCCAGGTTCTGAGGAGACAGGCCCCGGAGCAGCACTAGCTCCTGCCCACACTCCTACCTGCTGCCCTGA	16	207	2
T00369	GeneExpression	CXCL11	NM_005409	1,2	chr4	76956391	26M584N105M	Minus	GATATTGTGTGCTACAGTTGTTCAAGGCTTCCCCATGTTCAAAAGAGGACGCTGTCTTTGCATAGGCCCTGGGGTAAAAGCAGTGAAAGTGGCAGATATTGAGAAAGCCTCCATAATGTACCCAAGTAACA	16	101	1
T00370	GeneExpression	EOMES	NM_005442	2,3	chr3	27760950	113M689N23M	Minus	TCCCACTGCCCACTACAATGTGTTCGTAGAGGTGGTGCTGGCGGACCCCAACCACTGGCGCTTCCAGGGGGGCAAATGGGTGACCTGTGGCAAAGCCGACAATAACATGCAGGGCAACAAAATGTATGTTCACCCA	16	106	1
T00371	GeneExpression	CCR4	NM_005508	1,2	chr3	32993126	57M1681N80M	Plus	GAGCAAGCCTGGCATTGCCTCACAGACCTTCCTCAGAGCCGCTTTCAGAAAAGCAAGCTGCTTCTGGTTGGGCCCAGACCTGCCTTGAGGAGCCTGTAGAGTTAAAAAATGAACCCCACGGATATAGCAGACACCAC	16	107	1
T00372	GeneExpression	MLANA	NM_005511	3,4	chr9	5897570	84M9231N53M	Plus	GGCATCCTGACAGTGATCCTGGGAGTCTTACTGCTCATCGGCTGTTGGTATTGTAGAAGACGAAATGGATACAGAGCCTTGATGGATAAAAGTCTTCATGTTGGCACTCAATGTGCCTTAACAAGAAGATGCCCACA	16	107	1
T00373	GeneExpression		ENST00000490518		chr9	5897570	84M427N106M8698N53M	Plus	GGCATCCTGACAGTGATCCTGGGAGTCTTACTGCTCATCGGCTGTTGGTATTGTAGAAGACGAAATGGATACAGAGCCTTGATGGAAATCCTGGGATGGAGCGCAGTGGTGAACATGAGTCACTGTAGCCTTGACCTCCTGGGCTCAAGCCATCCTCCTGTCTCAGCCTCCAGAGTAGCTGGGACCACAGGATAAAAGTCTTCATGTTGGCACTCAATGTGCCTTAACAAGAAGATGCCCACA	16	213	2
T00374	GeneExpression	HLA-B	NM_005514	3,4	chr6	31323282	50M574N88M	Minus	GTGGCTCCGCAGATACCTGGAGAACGGGAAGGACAAGCTGGAGCGCGCTGACCCCCCAAAGACACACGTGACCCACCACCCCATCTCTGACCATGAGGCCACCCTGAGGTGCTGGGCCCTGGGTTTCTACCCTGCGGA	16	108	1
T00375	GeneExpression	HLA-E	NM_005516	3,4	chr6	30458180	113M621N26M	Plus	AAAGTCAAATGATGCCTCTGAGGCGGAGCACCAGAGAGCCTACCTGGAAGACACATGCGTGGAGTGGCTCCACAAATACCTGGAGAAGGGGAAGGAGACGCTGCTTCACCTGGAGCCCCCAAAGACACACGTGACTCAC	16	109	1
T00376	GeneExpression	IFI27	NM_005532	1,2	chr14	94577100	44M827N93M	Plus	ACGGTGAGGTCAGCTTCACATTCTCAGGAACTCTCCTTCTTTGGGTCTGGCTGAAGTTGAGGATCTCTTACTCTCTAGGCCACGGAATTAACCCGAGCAGGCATGGAGGCCTCTGCTCTCACCTCATCAGCAGTGAC	16	107	1
T00377	GeneExpression		ENST00000554448		chr14	94577100	44M861N59M	Plus	ACGGTGAGGTCAGCTTCACATTCTCAGGAACTCTCCTTCTTTGGGCCACGGAATTAACCCGAGCAGGCATGGAGGCCTCTGCTCTCACCTCATCAGCAGTGAC	16	73	2
T00378	GeneExpression	IFI35	NM_005533	3,4	chr17	41165124	88M72N50M	Plus	GAAGTGCCTAAGTCTTTAGTTTCCAATTTGCGGATCCACTGCCCTCTGCTTGCGGGCTCTGCTCTGATCACCTTTGATGACCCCAAAGTGGCTGAGCAGGTGCTGCAACAAAAGGAGCACACGATCAACATGGAGGAG	16	108	1
T00379	GeneExpression	IRS1	NM_005544	1,2	chr2	227600926	90M58738N41M	Minus	CGCTCAAGTGAGGATTTAAGCGCCTATGCCAGCATCAGTTTCCAGAAGCAGCCAGAGGACCGTCAGTAGCTCAACTGGACATCACAGCAGAATGAAGACCTAAATGACCTCAGCAAATCCTCTTCTAACTC	16	101	1
T00380	GeneExpression	ITK	NM_005546	5,6	chr5	156644888	30M4955N107M	Plus	CCTCTTCCTCCTACTCCTGAAGACAACAGGCGACCACTTTGGGAACCTGAAGAAACTGTGGTCATTGCCTTATATGACTACCAAACCAATGATCCTCAGGAACTCGCACTGCGGCGCAACGAAGAGTACTGCCTGCT	16	107	1
T00381	GeneExpression	KRT7	NM_005556	1,2	chr12	52627378	27M1534N107M	Plus	AACAAGTTTGCCTCCTTCATCGACAAGGTGCGGTTTCTGGAGCAGCAGAACAAGCTGCTGGAGACCAAGTGGACGCTGCTGCAGGAGCAGAAGTCGGCCAAGAGCAGCCGCCTCCCAGACATCTTTGAGGCCCA	16	104	1
T00382	GeneExpression	LAMP1	NM_005561	2,3	chr13	113960816	106M3036N36M	Plus	GTCAGCAGCAATGTTTATGGTGAAAAATGGCAACGGGACCGCGTGCATAATGGCCAACTTCTCTGCTGCCTTCTCAGTGAACTACGACACCAAGAGTGGCCCTAAGAACATGACCTTTGACCTGCCATCAGATGCCACAGTG	16	112	1
T00383	GeneExpression	LCN2	NM_005564	1,2	chr9	130911869	74M574N63M	Plus	ACTCCACCTCAGACCTGATCCCAGCCCCACCTCTGAGCAAGGTCCCTCTGCAGCAGAACTTCCAGGACAACCAATTCCAGGGGAAGTGGTATGTGGTAGGCCTGGCAGGGAATGCAATTCTCAGAGAAGACAAAGAC	16	107	1
T00384	GeneExpression	NKG7	NM_005601	3,4	chr19	51875021	69M104N69M	Minus	AGATCCAGACCTTCTTCTCCTGGTCCTTCTACCTGGGCTGGGTCTCAGCTATCCTCTTGCTCTGTACAGGTGCCCTGAGCCTGGGTGCTCACTGTGGCGGTCCCCGTCCTGGCTATGAAACCTTGTGAGCAGAAGGCA	16	108	1
T00385	GeneExpression	TDO2	NM_005651	1,2	chr4	156824884	62M224N76M	Plus	GTGCTTCTCAGACAGTGCCTTTTCACCATGAGTGGGTGCCCATTTTTAGGAAACAACTTTGGATATACTTTTAAAAAACTCCCCGTAGAAGGCAGCGAAGAAGACAAATCACAAACTGGTGTGAATAGAGCCAGCAAA	16	108	1
T00386	GeneExpression	EBI3	NM_005755	4,5	chr19	4234788	34M2111N106M	Plus	TTACAAGCGTCAGGGAGCTGCGCGCTTCCACCGGGTGGGGCCCATTGAAGCCACGTCCTTCATCCTCAGGGCTGTGCGGCCCCGAGCCAGGTACTACGTCCAAGTGGCGGCTCAGGACCTCACAGACTACGGGGAACTGA	16	110	1
T00387	GeneExpression	KLRG1	NM_005810	4,5	chr12	9161597	75M350N64M	Plus	GGCCTTTTGCTGGATTGGTCTGAGGAACAATTCTGGCTGGAGGTGGGAAGATGGATCACCTCTAAACTTCTCAAGGATTTCTTCTAATAGCTTTGTGCAGACATGCGGTGCCATCAACAAAAATGGTCTTCAAGCCTCA	16	109	1
T00388	GeneExpression	IGSF6	NM_005849	2,3	chr16	21655683	100M2736N35M	Minus	TCAAATGACAGTGCAATTTACATCTGTGGAATAGCATTCCCCAGTGTGCCGGAAGCGAGAGCTAAACAGACAGGAGGAGGGACCACACTGGTGGTAAGAGAAATTAAGCTGCTCAGCAAGGAACTGCGGAGCTTC	16	105	1
T00389	GeneExpression	SNAI1	NM_005985	1,2	chr20	48599635	44M682N95M	Plus	CAATCGGAAGCCTAACTACAGCGAGCTGCAGGACTCTAATCCAGAGTTTACCTTCCAGCAGCCCTACGACCAGGCCCACCTGCTGGCAGCCATCCCACCTCCGGAGATCCTCAACCCCACCGCCTCGCTGCCAATGCTC	16	109	1
T00390	GeneExpression	IKZF1	NM_006060	2,3	chr7	50358663	35M8536N108M	Plus	TGCTGATGAGGGTCAAGACATGTCCCAAGTTTCAGGGAAGGAAAGCCCCCCTGTAAGCGATACTCCAGATGAGGGCGATGAGCCCATGCCGATCCCCGAGGACCTCTCCACCACCTCGGGAGGACAGCAAAGCTCCAAGAGTG	16	113	1
T00391	GeneExpression	IRF9	NM_006084	8,9	chr14	24635141	31M159N103M	Plus	CCATACTCCACAGAATCTTATCACAGTGAAGATGGAGCAGGCCTTTGCCCGATACTTGCTGGAGCAGACTCCAGAGCAGCAGGCAGCCATTCTGTCCCTGGTGTAGAGCCTGGGGGACCCATCTTCCACCTCAC	16	104	1
T00392	GeneExpression	HLA-DMA	NM_006120	4,5	chr6	32916629	119M402N17M	Minus	CGCACTGCCCTCAGATCTGCTGGAGAATGTGCTGTGTGGCGTGGCCTTTGGCCTGGGTGTGCTGGGCATCATCGTGGGCATTGTTCTCATCATCTACTTCCGGAAGCCTTGCTCAGGTGACTGATTCTTCCAGACC	16	106	1
T00393	GeneExpression		ENST00000477541		chr6	32916629	116M405N17M	Minus	CGCACTGCCCTCAGATCTGCTGGAGAATGTGCTGTGTGGCGTGGCCTTTGGCCTGGGTGTGCTGGGCATCATCGTGGGCATTGTTCTCATCATCTACTTCCGGAAGCCTTGCTCAGACTGATTCTTCCAGACC	16	103	2
T00394	GeneExpression	CD28	NM_006139	2,3	chr2	204591667	46M2658N88M	Plus	TACCTAGACAATGAGAAGAGCAATGGAACCATTATCCATGTGAAAGGGAAACACCTTTGTCCAAGTCCCCTATTTCCCGGACCTTCTAAGCCCTTTTGGGTGCTGGTGGTGGTTGGTGGAGTCCTGGCTTGCTA	16	104	1
T00395	GeneExpression	GZMA	NM_006144	2,3	chr5	54401344	103M2175N28M	Plus	ATTCAAGACCCTACATGGTCCTACTTAGTCTTGACAGAAAAACCATCTGTGCTGGGGCTTTGATTGCAAAAGACTGGGTGTTGACTGCAGCTCACTGTAACTTGAACAAAAGGTCCCAGGTCATTCTTGGG	16	101	1
T00396	GeneExpression	NTN3	NM_006181	2,3	chr16	2522837	54M95N72M	Plus	AGGGCTTCTATCGAGACCCTGGCCGTGCCCTGAGTGACCGTCGGGCTTGCAGGGCCTGCGACTGTCACCCGGTTGGTGCTGCTGGCAAGACCTGCAACCAGACCACAGGCCAGTGTCCCTGCAAGG	16	96	1
T00397	GeneExpression	OAS3	NM_006187	3,4	chr12	113382385	72M2091N68M	Plus	AGGAACTTTGTGAACATTCGCCCAGCCAAGTTGAAGAACCTAATCTTGCTGGTGAAGCACTGGTACCACCAGGTGTGCCTACAGGGGTTGTGGAAGGAGACGCTGCCCCCGGTCTATGCCCTGGAATTGCTGACCATCTT	16	110	1
T00398	GeneExpression	PIK3CA	NM_006218	6,7	chr3	178922337	40M5006N97M	Plus	ACAATGTGAACACTCAAAGAGTACCTTGTTCCAATCCCAGGTGGAATGAATGGCTGAATTATGATATATACATTCCTGATCTTCCTCGTGCTGCTCGACTTTGCCTTTCCATTTGCTCTGTTAAAGGCCGAAAGGGT	16	107	1
T00399	GeneExpression	POU2AF1	NM_006235	1,2	chr11	111229563	57M20243N81M	Minus	TGTCGGCTTCAAAGAGAAAAGGCAACATCCTGTCACAGGCCATGCTCTGGCAAAAACCCACAGCTCCGGAGCAAGCCCCAGCCCCGGCCCGGCCATACCAGGGCGTCCGTGTGAAGGAGCCAGTGAAGGAACTGCTGA	16	108	1
T00400	GeneExpression		ENST00000530793		chr11	111229563	57M1309N79M18855N81M	Minus	TGTCGGCTTCAAAGAGAAAAGGCAACATCCTGTCACAGGCCATGCTCTGGCAAAAACGCGATGGAGCAGCGGCAGCCTATCCTTTCTGGGACAATGGCAGCTGACCCTGTTGTGAGTGCTGTGTGGATGAGAGCAGCCACAGCTCCGGAGCAAGCCCCAGCCCCGGCCCGGCCATACCAGGGCGTCCGTGTGAAGGAGCCAGTGAAGGAACTGCTGA	16	187	2
T00401	GeneExpression	BATF	NM_006399	1,2	chr14	75989005	84M2338N55M	Plus	AGAGCCCGGAAGATTTCAGCCATGCCTCACAGCTCCGACAGCAGTGACTCCAGCTTCAGCCGCTCTCCTCCCCCTGGCAAACAGGACTCATCTGATGATGTGAGAAGAGTTCAGAGGAGGGAGAAAAATCGTATTGCCG	16	109	1
T00402	GeneExpression	CXCL13	NM_006419	3,4	chr4	78528901	89M2778N47M	Plus	CAAGAGAGCTCAGTCTTTATCCCTAGACGCTTCATTGATCGAATTCAAATCTTGCCCCGTGGGAATGGTTGTCCAAGAAAAGAAATCATAGTCTGGAAGAAGAACAAGTCAATTGTGTGTGTGGACCCTCAAGCTG	16	106	1
T00403	GeneExpression	GNLY	NM_006433	2,3	chr2	85922498	49M534N88M	Plus	GCGTGATGAGGAGAAATCCTGCCCGTGCCTGGCCCAGGAGGGCCCCCAGGGTGACCTGTTGACCAAAACACAGGAGCTGGGCCGTGACTACAGGACCTGTCTGACGATAGTCCAAAAACTGAAGAAGATGGTGGATA	16	107	1
T00404	GeneExpression	IFITM2	NM_006435	1,2	chr11	308407	32M574N105M	Plus	TGGGCTTCATAGCATTCGCGTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	107	1
T00405	None		NR_049759		chr11	319886	32M579N100M	Minus	TGGGCTTCATAGCATTCGCCTACTCCGTGAAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCTTCATGACC	16	102	-1
T00406	None		NM_021034		chr11	319886	32M574N105M	Minus	TGGGCTTCATAGCATTCGCCTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCTTCATGACC	16	107	-2
T00407	GeneExpression		ENST00000527146		chr11	308407	32M316N135M123N105M	Plus	TGGGCTTCATAGCATTCGCGTACTCCGTGAAGACTGGCACCCAGGCTCTCCCAGAAAGTGAGAAGGGAACTCACAGGTGACTTCACCCCATGGTGGGGAGAACAGCCTGTGCTGGGGCCAAGGCAGAAGGAGGATGAGCCCCGAGGCTCCTGGAGAGTCTGAGCCGGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	242	2
T00408	None		ENST00000531688		chr11	319886	32M316N136M122N105M	Minus	TGGGCTTCATAGCATTCGCCTACTCCGTGAAGACTGGCACCCAGGCTCTCCCAGAAAGTGAGAAGGGAACTCACAGGTGACTTCACCCCATGGTGGGGAGAACAGCCTGTGCTGAGGTCAAGGCAGAAGGAGGATGAGCCCCGAGGCTCCTGGAGAGTCTGAGCCCGGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCTTCATGACC	16	243	-3
T00409	GeneExpression	PVR	NM_006505	3,4	chr19	45153296	82M3791N56M	Plus	GACGGCAAGAATGTGACCTGCAAGGTGGAGCACGAGAGCTTTGAGAAGCCTCAGCTGCTGACTGTGAACCTCACCGTGTACTACCCCCCAGAGGTATCCATCTCTGGCTATGATAACAACTGGTACCTTGGCCAGAAT	16	108	1
T00410	GeneExpression	CXCR6	NM_006564	1,2	chr3	45985005	28M2920N108M	Plus	GGAACAAACTGGCAAAGCATCTCTGCTGGTGTTCATCAGAACAGACACCATGGCAGAGCATGATTACCATGAAGACTATGGGTTCAGCAGTTTCAATGACAGCAGCCAGGAGGAGCATCAAGACTTCCTGCAGTTC	16	106	1
T00411	GeneExpression	CD226	NM_006566	4,5	chr18	67540458	110M22454N25M	Minus	CATCGTCATCCCCGATGTCACAGTCTCAGACTCGGGGCTTTACCGCTGCTACTTGCAGGCCAGCGCAGGAGAAAACGAAACCTTCGTGATGAGATTGACTGTAGCCGAGGGTAAAACCGATAACCAATATACCCT	16	105	1
T00412	GeneExpression	TNFSF13B	NM_006573	4,5	chr13	108955611	103M88N33M	Plus	ATTTGTTCCATGGCTTCTCAGCTTTAAAAGGGGAAGTGCCCTAGAAGAAAAAGAGAATAAAATATTGGTCAAAGAAACTGGTTACTTTTTTATATATGGTCAGGTTTTATATACTGATAAGACCTACGCCATGGGA	16	106	1
T00413	GeneExpression	CD6	NM_006725	10,11	chr11	60784977	46M208N94M	Plus	GAGGAGGTCCAGCAAAGCAGGTTCCAGATGCCACCCTTGGAGGAAGGACTTGAAGAGTTGCATGCCTCCCACATCCCAACTGCCAACCCTGGACACTGCATTACAGACCCGCCATCCCTGGGCCCTCAGTATCACCCGAG	16	110	1
T00414	GeneExpression		ENST00000505761		chr11	60784977	348M	Plus	GAGGAGGTCCAGCAAAGCAGGTTCCAGATGCCACCCTTGGAGGAAGGTGAGTCAGGATGGGAAGGGGTGTGAATGGCAGTCCCACCTCCAGAGAGTAGCTCAGCTCAGCTTGAGACCTTCCAGCAGGAACCTCCCTCAATGAGTCTTTCCTGACTTTCACAAATCCTATAGGCAGTAAGTGCTTTCTGAAGTCTGACTTAAAGCCCTCTTGCTGCACTGCTTCTTTCGTCACCATTCTCCCTTTCCTGCCTTAGGACTTGAAGAGTTGCATGCCTCCCACATCCCAACTGCCAACCCTGGACACTGCATTACAGACCCGCCATCCCTGGGCCCTCAGTATCACCCGAG	16	318	2
T00415	GeneExpression	LAPTM5	NM_006762	5,6	chr1	31210469	62M1240N78M	Minus	CCCTCTGCAGCTCCTACATGGAAGTGCCCACCTATCTCAACTTCAAGTCCATGAACCACATGAATTACCTCCCCAGCCAGGAGGATATGCCTCATAACCAGTTCATCAAGATGATGATCATCTTTTCCATCGCCTTCATC	16	110	1
T00416	GeneExpression	IFI44L	NM_006820	7,8	chr1	79106740	67M313N63M	Plus	TGATTGCAGTGAGGTTCTTCAAGACAACTTTTTAAACATGAGTAGATCTATGACTTCTCAAAGCCGGGTCATGAATGTCCATAAAATGCTAGGCATTCCTATTTCCAATATTTTGATGGTTGGAAATTAT	16	100	1
T00417	GeneExpression	PMEL	NM_006928	3,4	chr12	56355167	56M158N81M	Minus	GAACAGGCAGCTGTATCCAGAGTGGACAGAAGCCCAGAGACTTGACTGCTGGAGAGGTGGTCAAGTGTCCCTCAAGGTCAGTAATGATGGGCCTACACTGATTGGTGCAAATGCCTCCTTCTCTATTGCCTTGAACT	16	107	1
T00418	GeneExpression	CD160	NM_007053	3,4	chr1	145704320	113M2342N24M	Minus	CATTTGCTTCAAGTTCCTGGGCCTGCTGACAGCGTGCAGGATGCTGTTGGAACCCGGCAGAGGCTGCTGTGCCCTGGCCATCCTGCTGGCAATTGTGGACATCCAGTCTGGTGGATGCATTAACATCACCAGCTCAG	16	107	1
T00419	GeneExpression	CORO1A	NM_007074	2,3	chr16	30196655	74M1190N63M	Plus	TCAACCCTAAGTTTGTGGCCCTGATCTGTGAGGCCAGCGGGGGAGGGGCCTTCCTGGTGCTGCCCCTGGGCAAGACTGGACGTGTGGACAAGAATGCGCCCACGGTCTGTGGCCACACAGCCCCTGTGCTAGACATC	16	107	1
T00420	GeneExpression	LST1	NM_007161	1,2	chr6	31554983	113M322N16M	Plus	AACTTGAGGCAAGTCACCAGCCCCTGATCATTTCGCCTAAAAGAGCAAGGACTAGAGTTCCTGACCTCCAGGCCAGTCCCTGATCCCTGACCTAATGTTATCGCGGAATGATGATATATGTATCTACGG	16	99	1
T00421	None		ENST00000464526		chr6	31554983	451M	Plus	AACTTGAGGCAAGTCACCAGCCCCTGATCATTTCGCCTAAAAGAGCAAGGACTAGAGTTCCTGACCTCCAGGCCAGTCCCTGATCCCTGACCTAATGTTATCGCGGAATGATGGTAAGTAAAGTGTCTCTTGCATCTGCATAGAGAGAGTCCTGGGAGCTTAGGAAGTGATGGGGAACAGTGATGTATGCAGCTCATGACTAGGTGGACAGGCCTCTGGGGACAGCTGGTACAGGAGGGAAAGGGACCTCACGGGAGGCCCAGAAACCTGGTAAGAGGTGAGGTATTAAGGTCTGGGATGGAGAAGCTCTGAGGGTATATTTTTCTGCCTCTAAAACTGTTGGAGAGGGAATCTGAGAAAGCTGCAACCAACCAGGAGGCTGGGGTACGCTGGAGAAGGAATGGGCTTCCTAACCTTGAGCCCTCTTCCCTGAAGATATATGTATCTACGG	16	421	-1
T00422	GeneExpression	BRCA1	NM_007300	10,11	chr17	41243025	110M402N25M	Minus	AAGCCAGGGAGTTGGTCTGAGTGACAAGGAATTGGTTTCAGATGATGAAGAAAGAGGAACGGGCTTGGAAGAAAATAATCAAGAAGAGCAAAGCATGGATTCAAACTTAGGTGAAGCAGCATCTGGGTGTGAGAG	16	105	1
T00423	GeneExpression	STAT1	NM_007315	18,19	chr2	191845355	99M1713N41M	Minus	GGGCTCAGCTTTCAGAAGTGCTGAGTTGGCAGTTTTCTTCTGTCACCAAAAGAGGTCTCAATGTGGACCAGCTGAACATGTTGGGAGAGAAGCTTCTTGGTCCTAACGCCAGCCCCGATGGTCTCATTCCGTGGACGAGG	16	110	1
T00424	GeneExpression	DMBT1	NM_007329	50,51	chr10	124395693	23M928N114M	Plus	CAGTCCCTCCAATGACAGCACCAACCTGCTCTGTCTGCCAAATCACATGCAAGCCAGTGTGAGCAGGAGCTATCTCCAATCCTTGGGCTTTTCTGCCAGTGACCTTGTCATTTCCACCTGGAATGGATACTACGAGT	16	107	1
T00425	GeneExpression	KLRK1	NM_007360	7,8	chr12	10525722	28M4900N109M	Minus	AAGATGGCTCCATTCTCTCACCCAACCTACTAACAATAATTGAAATGCAGAAGGGAGACTGTGCACTCTATGCCTCGAGCTTTAAAGGCTATATAGAAAACTGTTCAACTCCAAATACGTACATCTGCATGCAAAGG	16	107	1
T00426	GeneExpression	ICOS	NM_012092	2,3	chr2	204820600	95M687N41M	Plus	CCATTCTCATGCCAACTATTACTTCTGCAACCTATCAATTTTTGATCCTCCTCCTTTTAAAGTAACTCTTACAGGAGGATATTTGCATATTTATGAATCACAACTTTGTTGCCAGCTGAAGTTCTGGTTACCCATA	16	106	1
T00427	GeneExpression	TRIM29	NM_012101	1,2	chr11	119999127	62M8732N77M	Minus	TGTTCCAGGAGCACAAGAATCATAGCACCGTGACAGTGGAGGAGGCCAAGGCCGAGAAGGAGACGGAGCTGTCATTGCAAAAGGAGCAGCTGCAGCTCAAGATCATTGAGATTGAGGATGAAGCTGAGAAGTGGCAGAA	16	109	1
T00428	GeneExpression	IKZF3	NM_012481	4,5	chr17	37947774	75M1089N63M	Minus	AGATGAACTGCGATGTGTGTGGATTATCCTGCATCAGCTTCAATGTCTTAATGGTTCATAAGCGAAGCCATACTGGTGAACGCCCATTCCAGTGTAATCAGTGTGGGGCATCTTTTACTCAGAAAGGTAACCTCCTCC	16	108	1
T00429	GeneExpression	TBX21	NM_013351	3,4	chr17	45820489	70M1002N72M	Plus	GCGCCAGGAAGTTTCATTTGGGAAACTAAAGCTCACAAACAACAAGGGGGCGTCCAACAATGTGACCCAGATGATTGTGCTCCAGTCCCTCCATAAGTACCAGCCCCGGCTGCATATCGTTGAGGTGAACGACGGAGAGCCA	16	112	1
T00430	GeneExpression	FOXP3	NM_014009	7,8	chrX	49111904	74M205N67M	Minus	ACCATCTTCTGGATGAGAAGGGCAGGGCACAATGTCTCCTCCAGAGAGAGATGGTACAGTCTCTGGAGCAGCAGCTGGTGCTGGAGAAGGAGAAGCTGAGTGCCATGCAGGCCCACCTGGCTGGGAAAATGGCACTGACCA	16	111	1
T00431	GeneExpression	CD274	NM_014143	3,4	chr9	5457364	57M5413N82M	Plus	GCTGCATGATCAGCTATGGTGGTGCCGACTACAAGCGAATTACTGTGAAAGTCAATGCCCCATACAACAAAATCAACCAAAGAATTTTGGTTGTGGATCCAGTCACCTCTGAACATGAACTGACATGTCAGGCTGAGGG	16	109	1
T00432	GeneExpression	KIR2DL1	NM_014218	1,2,3	chr19	55281258	79M964N36M2448N49M	Plus	CTGAGCTGAGCTCGGTCGCGGCTGCCTGTCTGCTCCGGCAGCACCATGTCGCTCTTGGTCGTCAGCATGGCGTGTGTTGGGTTCTTCTTGCTGCAGGGGGCCTGGCCACATGAGGGAGTCCACAGAAAACCTTCCCTCCTGGCCCACCCAGGTCGCCTGGTGAA	16	134	1
T00433	GeneExpression	DDX58	NM_014314	3,4	chr9	32492460	57M1222N77M	Minus	ATCATTTCTGATCTGTCTGAATGTTTAATTAATCAGGAATGTGAAGAAATTCTACAGATTTGCTCTACTAAGGGGATGATGGCAGGTGCAGAGAAATTGGTGGAATGCCTTCTCAGATCAGACAAGGAAAACTG	16	104	1
T00434	GeneExpression	TNFAIP8	NM_014350	1,2	chr5	118691768	49M36694N89M	Plus	GCTGGTTATCCTGACATTATGCACTCCGAAGCAGAAGAATCCAAGGAAGTGGCCACAGATGTCTTTAATTCCAAAAACCTGGCCGTTCAGGCACAAAAGAAGATCTTGGGTAAAATGGTGTCCAAATCCATCGCCACC	16	108	1
T00435	GeneExpression		ENST00000415806		chr5	118691768	49M35243N119M1332N89M	Plus	GCTGGTTATCCTGACATTATGCACTCCGAAGCAGAAGAATCCAAGGAAGGCCTAGGCTTAAACACTGGCATATATGGAGAGAACAGTTGCCACTCGACTCAGAGATTGAGTAGACACCCAAAGAACTGCAGTTCTTAAGCCTTAGGAGAAGCGAGAGAAATGGGCCAGTGGCCACAGATGTCTTTAATTCCAAAAACCTGGCCGTTCAGGCACAAAAGAAGATCTTGGGTAAAATGGTGTCCAAATCCATCGCCACC	16	227	2
T00436	GeneExpression	LAMP3	NM_014398	5,6	chr3	182841985	121M11502N18M	Minus	GTCGGGCATTCCTTCAAGTGCGTGAGTGAACAGAGCCTCCAGTTGTCAGCCCACCTGCAGGTGAAAACAACCGATGTCCAACTTCAAGCCTTTGATTTTGAAGATGACCACTTTGGAAATGTGGATGAGTGCTCGTCTG	16	109	1
T00437	GeneExpression	SIT1	NM_014450	1,2	chr9	35650563	65M116N72M	Minus	CTTGTGGACTCTCACATCTGCAGCCATGAGCAGAGGCGACAACTGCACGGATCTACTCGCACTGGGAATCCCCTCCATAACCCAGGCCTGGGGACTGTGGGTCCTCTTAGGGGCTGTGACGCTGCTATTTCTCATCT	16	107	1
T00438	GeneExpression	KIAA0101	NM_014736	3,4	chr15	64658256	119M10667N19M	Minus	ACTCCCAAGTGGCAAAAAGGAATTGGAGAATTCTTTAGGTTGTCCCCTAAAGATTCTGAAAAAGAGAATCAGATTCCTGAAGAGGCAGGAAGCAGTGGCTTAGGAAAAGCAAAGAGAAAAGCATGTCCTTTGCAACCT	16	108	1
T00439	GeneExpression		ENST00000558008		chr15	64658256	119M2978N67M7622N19M	Minus	ACTCCCAAGTGGCAAAAAGGAATTGGAGAATTCTTTAGGTTGTCCCCTAAAGATTCTGAAAAAGAGAATCAGATTCCTGAAGAGGCAGGAAGCAGTGGCTTAGGAAAAGCAAAGAGAAACCAGGAGCCACCCATCCTCCAGCACACTGAGCAGCAAGCTGGACACACGGCACACTGATCCAAATGGAGCATGTCCTTTGCAACCT	16	175	2
T00440	GeneExpression	MELK	NM_014791	3,4	chr9	36583666	44M5823N88M	Plus	GAGAGATGGTAGCTATAAAAATCATGGATAAAAACACACTAGGGAGTGATTTGCCCCGGATCAAAACGGAGATTGAGGCCTTGAAGAACCTGAGACATCAGCATATATGTCAACTCTACCATGTGCTAGAGA	16	102	1
T00441	GeneExpression	ICOSLG	NM_015259	3,4	chr21	45655383	73M1304N63M	Minus	CACTGCCTGGTGTTGAGCCAATCCCTGGGATTCCAGGAGGTTTTGAGCGTTGAGGTTACACTGCATGTGGCAGCAAACTTCAGCGTGCCCGTCGTCAGCGCCCCCCACAGCCCCTCCCAGGATGAGCTCACCTTCA	16	106	1
T00442	GeneExpression	SAMHD1	NM_015474	15,16	chr20	35521395	62M4755N75M	Minus	TGTATGCCGCAAGACAATATTTTGTTCAGTGGTGTGCAGACAGAAATTTCACCAAGCCGCAGGATGGCGATGTTATAGCCCCACTCATAACACCTCAAAAAAAGGAATGGAACGACAGTACTTCAGTCCAAAATCCA	16	107	1
T00443	GeneExpression	KIR2DL3	NM_015868	4,5,6	chr19	55255474	63M3250N51M4263N20M	Plus	CTTTCCGTGACTCTCCATACGAGTGGTCAAACTCGAGTGACCCACTGCTTGTTTCTGTCACAGGAAACCCTTCAAATAGTTGGCCTTCACCCACTGAACCAAGCTCCGAAACCGGTAACCCCAGACACCTGCAT	16	104	1
T00444	None		NM_014218		chr19	55286848	63M3153N51M4259N20M	Plus	CTTTCCGTGACTCTCCATACGAGTGGTCAAAGTCAAGTGACCCACTGCTTGTTTCTGTCACAGGAAACCCTTCAAATAGTTGGCCTTCACCCACTGAACCAAGCTCCAAAACCGGTAACCCCAGACACCTGCAT	16	104	-1
T00445	None		NM_013289		chr19	55333251	63M3169N51M4282N20M	Plus	CTTTCCGTGACTCTCCCTACGAGTGGTCAGACCCGAGTGACCCACTGCTTGTTTCTGTCACAGGAAACCCTTCAAGTAGTTGGCCTTCACCCACAGAACCAAGCTCCAAATCTGGTAACCCCAGACACCTGCAT	16	104	-2
T00446	None		NM_012314		chr19	55351092	63M3168N51M4265N20M	Plus	CTTTCCGTGACTCTCCCTACGAGTGGTCAAACTCGAGTGATCCACTGCTTGTTTCCGTCACAGGAAACCCTTCAAATAGTTGGCCTTCACCCACTGAACCAAGCTCCAAAACCGGTAACCCCAGACACCTGCAT	16	104	-3
T00447	None		ENST00000434419		chr19	55255474	63M19806N51M18980N20M	Plus	CTTTCCGTGACTCTCCATACGAGTGGTCAAACTCGAGTGACCCACTGCTTGTTTCTGTCACAGGAAACCCTTCAAATAGTTGGCCTTCACCCACTGAACCAAGCTCCAAAACCGGTAACCCCAGACACCTGCAT	16	104	-4
T00448	None		ENST00000291633		chr19	55286848	63M3153N51M1426N78M2755N20M	Plus	CTTTCCGTGACTCTCCATACGAGTGGTCAAAGTCAAGTGACCCACTGCTTGTTTCTGTCACAGGAAACCCTTCAAATAGTTGGCCTTCACCCACTGAACCAAGCTCCAAAACCGAGAGGATGTTTCACCACGTTGGCCAAGCTTGTCTGAAACTCCCAACCTCAAGTGATCCGACCGTCTCAGCATGCCAAAGTAACCCCAGACACCTGCAT	16	182	-5
T00449	GeneExpression	C1QA	NM_015991	1,2	chr1	22963169	27M907N108M	Plus	CCAGTTGGAGTTGACAACAGGAGGCAGAGGCATCATGGAGGGTCCCCGGGGATGGCTGGTGCTCTGTGTGCTGGCCATATCGCTGGCCTCTATGGTGACCGAGGACTTGTGCCGAGCACCAGACGGGAAGAAAGG	16	105	1
T00450	GeneExpression	MAGEC2	NM_016249	2,3	chrX	141291749	49M308N91M	Minus	GCCTAAAGTCAGCACAGCAGAGGAGGCCCAGGCAGTGCCAGGAGTCAAGGCCTGTTGGATCTCATCATCCATATCCCTGTTGATACGTTTACCTGCTGCTCCTGAAGAAGTCGTCATGCCTCCCGTTCCAGGCGTTCCAT	16	110	1
T00451	GeneExpression	IKZF2	NM_016260	4,5	chr2	213914526	54M6952N79M	Minus	GCATGGTTTGCATTGGGCCCAATGTGCTTATGGTACATAAAAGGAGTCACACTGGTGAACGCCCCTTCCACTGTAACCAGTGTGGAGCTTCTTTTACTCAGAAGGGCAACCTTCTGAGACACATAAAGTTACA	16	103	1
T00452	GeneExpression		ENST00000439848		chr2	213914526	54M88N179M6685N79M	Minus	GCATGGTTTGCATTGGGCCCAATGTGCTTATGGTACATAAAAGGAGTCACACTGGGGTGGCAGTGGTGAAAACTACCTTTTCAGAATTCTGCTAGTATTGGATTGCAGAAAAACAGAGAGTAGCCTGGGTCTTGACTTCCAGCCTTCAAATCTGAATAGCATATCAGAAAAGAAGTTTGGGATTCAGTTTCCACAGTTCTTAATATAGCAATAATATGATAAGGGTTCAAAAGGTGAACGCCCCTTCCACTGTAACCAGTGTGGAGCTTCTTTTACTCAGAAGGGCAACCTTCTGAGACACATAAAGTTACA	16	282	2
T00453	GeneExpression	KLF2	NM_016270	2,3	chr19	16436763	81M823N56M	Plus	CTCACACCTGCAGCTACGCGGGCTGCGGCAAGACCTACACCAAGAGTTCGCATCTGAAGGCGCATCTGCGCACGCACACAGGTGAGAAGCCCTACCACTGCAACTGGGACGGCTGCGGCTGGAAGTTTGCGCGCTCA	16	107	1
T00454	GeneExpression	KLRF1	NM_016523	2,3	chr12	9984935	76M888N52M	Plus	TATAAAATCTTACTGGGAATATCTGGAACCGTGAATGGTATTCTCACTTTGACTTTGATCTCCTTGATCCTGTTGGTTTCTCAGGGAGTATTGCTAAAATGCCAAAAAGGAAGTTGTTCAAATGCCAC	16	98	1
T00455	GeneExpression	TLR7	NM_016562	2,3	chrX	12885642	59M17930N79M	Plus	CATGCTCTGCTCTCTTCAACCAGACCTCTACATTCCATTTTGGAAGAAGACTAAAAATGGTGTTTCCAATGTGGACACTGAAGAGACAAATTCTTATCCTTTTTAACATAATCCTAATTTCCAAACTCCTTGGGGCTA	16	108	1
T00456	GeneExpression	IL23A	NM_016584	2,3	chr12	56733252	57M166N79M	Plus	CCCCATATCCAGTGTGGAGATGGCTGTGACCCCCAAGGACTCAGGGACAACAGTCAGTTCTGCTTGCAAAGGATCCACCAGGGTCTGATTTTTTATGAGAAGCTGCTAGGATCGGATATTTTCACAGGGGAGCCTT	16	106	1
T00457	GeneExpression	OAS1	NM_016816	3,4	chr12	113349022	19M5273N120M	Plus	CAAGCACTGGTACCAAAATTGTAAGAAGAAGCTTGGGAAGCTGCCACCTCAGTATGCCCTGGAGCTCCTGACGGTCTATGCTTGGGAGCGAGGGAGCATGAAAACACATTTCAACACAGCCCAGGGATTTCGGACGGTC	16	109	1
T00458	GeneExpression	OAS2	NM_016817	7,8	chr12	113443002	26M1190N114M	Plus	TGTGCTTCCTGCCTTTAATGCACTGGGTCAGCTGAGTTCTGGCTCCACACCCAGCCCCGAGGTTTATGCAGGGCTCATTGATCTGTATAAATCCTCGGACCTCCCGGGAGGAGAGTTTTCTACCTGTTTCACAGTCCTGC	16	110	1
T00459	GeneExpression	TLR9	NM_017442	1,2	chr3	52258224	34M1214N105M	Minus	AGACCCTCTGGAGAAGCCCCTGCCCCCCAGCATGGGTTTCTGCCGCAGCGCCCTGCACCCGCTGTCTCTCCTGGTGCAGGCCATCATGCTGGCCATGACCCTGGCCCTGGGTACCTTGCCTGCCTTCCTACCCTGTGAG	16	109	1
T00460	GeneExpression		ENST00000478201		chr3	52258224	34M1259N60M	Minus	AGACCCTCTGGAGAAGCCCCTGCCCCCCAGCATGGCCATCATGCTGGCCATGACCCTGGCCCTGGGTACCTTGCCTGCCTTCCTACCCTGTGAG	16	64	2
T00461	GeneExpression	HERC6	NM_017912	12,13	chr4	89334364	55M4158N80M	Plus	GTTCCATTTGCAAAGGCTGTGTGTGAAATGAGTAAACAATCTTTGCAAGTCCTAAAGAAGTGTTGGGCATTTTTGCAAGAATCTTCTCTGAATCCGCTGATCCAGATGCTTAAAGCAGCCATCATCTCTCAGCTG	16	105	1
T00462	GeneExpression	B3GAT1	NM_018644	2,3	chr11	134257520	72M132N69M	Minus	GACCCCTTCTCAGACTCCAGTTGGGCCGGACTCTCCAAACCTGCTTCCGCAATGGGTGGGTTGTGAGTGCTGGTAATGAGGAGCCGTGGGTGCAGCCAGCCTTGGAGATGCCGAAGAGACGGGACATCCTAGCGATCGTCC	16	111	1
T00463	GeneExpression		NM_054025		chr11	134257520	273M	Minus	GACCCCTTCTCAGACTCCAGTTGGGCCGGACTCTCCAAACCTGCTTCCGCAATGGGTGGGTTGTGAGTGCTGGTAAGACCTGCTAGCCAACATTCAGCTGCTCTGTCCTCTCCATGCCTGGCCGGCCCGGCCCATGCCTGTTCTTTTCTCCCCTGTGCTGCCGCCGCCCGTGGCCGCCCCTCTCCTGAACTTACCGCCACTCAGGTAATGAGGAGCCGTGGGTGCAGCCAGCCTTGGAGATGCCGAAGAGACGGGACATCCTAGCGATCGTCC	16	243	2
T00464	GeneExpression		ENST00000524765		chr11	134257520	55M149N69M	Minus	GACCCCTTCTCAGACTCCAGTTGGGCCGGACTCTCCAAACCTGCTTCCGCAATGGGTAATGAGGAGCCGTGGGTGCAGCCAGCCTTGGAGATGCCGAAGAGACGGGACATCCTAGCGATCGTCC	16	94	3
T00465	GeneExpression	HLA-DRA	NM_019111	1,2	chr6	32407789	21M2415N118M	Plus	AGGAATCATGGGCTATCAAAGAAGAACATGTGATCATCCAGGCCGAGTTCTATCTGAATCCTGACCAATCAGGCGAGTTTATGTTTGACTTTGATGGTGATGAGATTTTCCATGTGGATATGGCAAAGAAGGAGACGGT	16	109	1
T00466	GeneExpression	CRTAM	NM_019604	3,4	chr11	122722504	50M2097N86M	Plus	ACATTACAGCGACTCTGTAAGCACAAAGGAAGTGAAAGTGATTGTGCTGGCAACTCCTTTCAAGCCAATCCTGGAAGCTTCAGTTATCAGAAAGCAAAATGGAGAAGAACATGTTGTACTCATGTGCTCCACCATG	16	106	1
T00467	GeneExpression	HLA-DQA2	NM_020056	4,5	chr6	32714170	22M167N106M	Plus	GAATCCCATCCTGAAAAGGAAGGTGCATCACCATCTACAGGAGAAGAAGAATGGACTTGCTAAATGACCTAGCACTATTCTCTGGCCTGATTTATCATATCCCTTTTCTCCTCCAAATGTTTCTTCTC	16	98	1
T00468	GeneExpression	SLAMF8	NM_020125	4,5	chr1	159803060	100M1814N40M	Plus	AAGGCCTCCTACAAAGATGTGCTGCTGGTGGTGGTGCCTGTCTCGCTGCTCCTGATGCTGGTTACTCTCTTCTCTGCCTGGCACTGGTGCCCCTGCTCAGGGAAAAAGAAAAAGGATGTCCATGCTGACAGAGTGGGTCC	16	110	1
T00469	GeneExpression	IL22	NM_020525	2,3	chr12	68646369	58M116N59M	Minus	GGCTGATAACAACACAGACGTTCGTCTCATTGGGGAGAAACTGTTCCACGGAGTCAGTATGAGTGAGCGCTGCTATCTGATGAAGCAGGTGCTGAACTTCACCCTTGAAGAAGTGCT	16	87	1
T00470	GeneExpression	NFKBIA	NM_020529	4,5	chr14	35871761	28M107N109M	Minus	GTCCTTGGGTGCTGATGTCAATGCTCAGGAGCCCTGTAATGGCCGGACTGCCCTTCACCTCGCAGTGGACCTGCAAAATCCTGACCTGGTGTCACTCCTGTTGAAGTGTGGGGCTGATGTCAACAGAGTTACCTACC	16	107	1
T00471	GeneExpression		ENST00000555371		chr14	35871761	244M	Minus	GTCCTTGGGTGCTGATGTCAATGCTCAGGTTGGTGCTTCCTGCCCCCGACGCACTGAGTCAGGCTCCTCGTGCTTATGTTGTGAGCAGAAATTCCAAATGCAGCCATAAGCATCTCAAATTCCTTTTGGTTTCAGGAGCCCTGTAATGGCCGGACTGCCCTTCACCTCGCAGTGGACCTGCAAAATCCTGACCTGGTGTCACTCCTGTTGAAGTGTGGGGCTGATGTCAACAGAGTTACCTACC	16	214	2
T00472	GeneExpression	MAGEA10	NM_021048	3,4	chrX	151304100	52M75N58M	Minus	AAGAGGTCAAGAGCTGTGGGACACCACAGAGCAGCACTGAAGGAGAAGACCTGCCTGTGGGTCCCCATCGCCCAAGTCCTGCCCACACTCCCACCTGCTACCCTGATCAG	16	80	1
T00473	GeneExpression	CD209	NM_021155	6,7	chr19	7808091	104M866N36M	Minus	CAGCTGCAGTCTTCCAGAAGTAACCGCTTCACCTGGATGGGACTTTCAGATCTAAATCAGGAAGGCACGTGGCAATGGGTGGACGGCTCACCTCTGTTGCCCAGCTTCAAGCAGTATTGGAACAGAGGAGAGCCCAACAA	16	110	1
T00474	GeneExpression	SLAMF7	NM_021181	6,7	chr1	160721988	51M857N84M	Plus	AAGGAAGATCCAGCAAATACGGTTTACTCCACTGTGGAAATACCGAAAAAGATGGAAAATCCCCACTCACTGCTCACGATGCCAGACACACCAAGGCTATTTGCCTATGAGAATGTTATCTAGACAGCAGTGCAC	16	105	1
T00475	GeneExpression	IFNA17	NM_021268	1	chr9	21227419	128M	Minus	ATGAGTTCCTCCATTTCAAAGACTCACTTCTATAACCACCACGAGTTGAATCAAAATTTTCAAATGTTTTCAGCAGTGTAAAGAAGCGTCGTGTATACCTGTGCAGGCACTAGTACTTTACAGATGAC	16	98	1
T00476	GeneExpression	IL21	NM_021803	3,4	chr4	123534025	54M2753N59M	Minus	CTGAAGAGGAAACCACCTTCCACAAATGCAGGGAGAAGACAGAAACACAGACTAACATGCCCTTCATGTGATTCTTATGAGAAAAAACCACCCAAAGAATTCCTAGAAAGATT	16	83	1
T00477	GeneExpression	AXL	NM_021913	19,20	chr19	41763483	52M1923N88M	Plus	ATCTGCGCCAGGGAAATCGCCTGAAGCAGCCTGCGGACTGTCTGGATGGACTGTATGCCTTGATGTCGCGGTGCTGGGAGCTAAATCCCCAGGACCGGCCAAGTTTTACAGAGCTGCGGGAAGATTTGGAGAACACACTG	16	110	1
T00478	GeneExpression	MS4A1	NM_021950	1,2	chr11	60223393	26M6413N110M	Plus	TGAGATTTGAGGCCTTGGAGACTCAGGAGTTTTGAGAGCAAAATGACAACACCCAGAAATTCAGTAAATGGGACTTTCCCGGCAGAGCCAATGAAAGGCCCTATTGCTATGCAATCTGGTCCAAAACCACTCTTCA	16	106	1
T00479	GeneExpression		NM_152866		chr11	60223393	26M5126N89M1024N284M	Plus	TGAGATTTGAGGCCTTGGAGACTCAGATCCTGAACAAGAGAGAACAAAATCTCTACTTTGATGGAACTTCCATTCTGTGGGGAAGAGACTGACAATAAGCAATTAAATAAATAAGAACTCAGCAGTAGGCCTTGCCTCAGATCCAAGGTCACTCGGAAGAGGCCATGTCTACCCTCAATGACACTCATGGAGGAAATGCTGAGAGAAGCATTCAGATGCATGACACAAGGTAAGACTGCCAAAAATCTTGTTCTTGCTCTCCTCATTTTGTTATTTGTTTTATTTTTAGGAGTTTTGAGAGCAAAATGACAACACCCAGAAATTCAGTAAATGGGACTTTCCCGGCAGAGCCAATGAAAGGCCCTATTGCTATGCAATCTGGTCCAAAACCACTCTTCA	16	369	2
T00480	GeneExpression		ENST00000534668		chr11	60223393	26M6239N284M	Plus	TGAGATTTGAGGCCTTGGAGACTCAGAACTCAGCAGTAGGCCTTGCCTCAGATCCAAGGTCACTCGGAAGAGGCCATGTCTACCCTCAATGACACTCATGGAGGAAATGCTGAGAGAAGCATTCAGATGCATGACACAAGGTAAGACTGCCAAAAATCTTGTTCTTGCTCTCCTCATTTTGTTATTTGTTTTATTTTTAGGAGTTTTGAGAGCAAAATGACAACACCCAGAAATTCAGTAAATGGGACTTTCCCGGCAGAGCCAATGAAAGGCCCTATTGCTATGCAATCTGGTCCAAAACCACTCTTCA	16	280	3
T00481	GeneExpression		ENST00000527101		chr11	60223393	26M5126N89M1024N114M119N51M	Plus	TGAGATTTGAGGCCTTGGAGACTCAGATCCTGAACAAGAGAGAACAAAATCTCTACTTTGATGGAACTTCCATTCTGTGGGGAAGAGACTGACAATAAGCAATTAAATAAATAAGAACTCAGCAGTAGGCCTTGCCTCAGATCCAAGGTCACTCGGAAGAGGCCATGTCTACCCTCAATGACACTCATGGAGGAAATGCTGAGAGAAGCATTCAGATGCATGACACAAGAGCCAATGAAAGGCCCTATTGCTATGCAATCTGGTCCAAAACCACTCTTCA	16	250	4
T00482	GeneExpression	FOXM1	NM_021953	4,5	chr12	2975636	90M2041N52M	Minus	GAGAGGAAGCGCATGACTTTGAAAGACATCTATACGTGGATTGAGGACCACTTTCCCTACTTTAAGCACATTGCCAAGCCAGGCTGGAAGAACTCCATCCGCCACAACCTTTCCCTGCACGACATGTTTGTCCGGGAGACGT	16	112	1
T00483	GeneExpression	C10orf54	NM_022153	2,3	chr10	73520647	106M673N35M	Minus	CTGACCCTGCTGGATAGCGGCCTCTACTGCTGCCTGGTGGTGGAGATCAGGCACCACCACTCGGAGCACAGGGTCCATGGTGCCATGGAGCTGCAGGTGCAGACAGGCAAAGATGCACCATCCAACTGTGTGGTGTACCCA	16	111	1
T00484	GeneExpression	IFIH1	NM_022168	8,9	chr2	163134743	41M1667N96M	Minus	AGCCATGCAAGAAGTTTGCCATTGCAGATGCAACCAGAGAAGATCCATTTAAAGAGAAACTTCTAGAAATAATGACAAGGATTCAAACTTATTGTCAAATGAGTCCAATGTCAGATTTTGGAACTCAACCCTATGAA	16	107	1
T00485	GeneExpression	IKZF4	NM_022465	2,3	chr12	56417509	40M1289N97M	Plus	GACTCCAACCATTTTATAATGGAATCTTTATTTTGTGAAAGTAGCGGGGACTCATCTCTGGAGAAGGAGTTCCTCGGGGCCCCAGTGGGGCCCTCGGTGAGCACCCCCAACAGCCAGCACTCTTCTCCTAGCCGCTC	16	107	1
T00486	GeneExpression	IFI6	NM_022873	1,2	chr1	27995778	60M2776N80M	Minus	TGCTGTGCCCATCTATCAGCAGGCTCCGGGCTGAAGATTGCTTCTCTTCTCTCCTCCAAGGTCTAGTGACGGAGCCCGCGCGCGGCGCCACCATGCGGCAGAAGGCGGTATCGCTTTTCTTGTGCTACCTGCTGCTCTTC	16	110	1
T00487	GeneExpression	VTCN1	NM_024626	1,2	chr1	117712759	104M40652N35M	Minus	GTGAGTCACCAAGGAAGGCAGCGGCAGCTCCACTCAGCCAGTACCCAGATACGCTGGGAACCTTCCCCAGCCATGGCTTCCCTGGGGCAGATCCTCTTCTGGAGCATAATTAGCATCATCATTATTCTGGCTGGAGCAA	16	109	1
T00488	GeneExpression	ZBTB46	NM_025224	3,4	chr20	62384183	103M22816N32M	Minus	CTCATGAGTAAGAACAGCCTGCTGTCGCTGAAGGCCGACGTGCTGGGGGATGACGGCTCCCTGCTGTTCGAGTACCTGCCCAGAGGGGCCCACTCGCTGTCCCTGAATGAGTTCACGGTGATCAGGAAGAAGTTC	16	105	1
T00489	GeneExpression	PDCD1LG2	NM_025239	2,3	chr9	5522573	29M12143N110M	Plus	CCTGGAATTGCAGCTTCACCAGATAGCAGCTTTATTCACAGTGACAGTCCCTAAGGAACTGTACATAATAGAGCATGGCAGCAATGTGACCCTGGAATGCAACTTTGACACTGGAAGTCATGTGAACCTTGGAGCAATA	16	109	1
T00490	GeneExpression	KREMEN1	NM_032045	8,9	chr22	29536313	42M1577N92M	Plus	CACAGCCATTGTAGCAAAGATACTTCTGCACGTCACATTCAAATCCCATCGTGTTCCTGCTTCAGGGGACCTTAGGGATTGTCATCAACCAGGGACTTCGGGGGAAATCTGGAGCATTTTTTACAAGCCTTCCA	16	104	1
T00491	GeneExpression	DGAT2	NM_032564	2,3	chr11	75495706	86M5441N54M	Plus	TGTCACCTGGCTCAATAGGTCCAAGGTGGAAAAGCAGCTACAGGTCATCTCAGTGCTCCAGTGGGTCCTGTCCTTCCTTGTACTGGGAGTGGCCTGCAGTGCCATCCTCATGTACATATTCTGCACTGATTGCTGGCTCA	16	110	1
T00492	GeneExpression	HAVCR2	NM_032782	2,3	chr5	156531689	70M1877N72M	Minus	TGCTGCCGGATCCAAATCCCAGGCATAATGAATGATGAAAAATTTAACCTGAAGTTGGTCATCAAACCAGCCAAGGTCACCCCTGCACCGACTCGGCAGAGAGACTTCACTGCAGCCTTTCCAAGGATGCTTACCACCAGGG	16	112	1
T00493	GeneExpression	GZMH	NM_033423	2,3	chr14	25076910	93M517N44M	Minus	TGTTCAGTTTCTGCAAGAGAAGAGTCGGAAGAGGTGTGGCGGCATCCTAGTGAGAAAGGACTTTGTGCTGACAGCTGCTCACTGCCAGGGAAGCTCCATAAATGTCACCTTGGGGGCCCACAATATCAAGGAACAGG	16	107	1
T00494	GeneExpression	HLA-DPA1	NM_033554	1,2	chr6	33037619	94M3584N45M	Minus	CCTGAAGACAGAATGTTCCATATCAGAGCTGTGATCTTGAGAGCCCTCTCCTTGGCTTTCCTGCTGAGTCTCCGAGGAGCTGGGGCCATCAAGGCGGACCATGTGTCAACTTATGCCGCGTTTGTACAGACGCATAGAC	16	109	1
T00495	GeneExpression		ENST00000463066		chr6	33037619	126M3552N45M	Minus	CCTGAAGACAGAATGTTCCATATCAGAGCTGTGATCTTGAGAGCCCTCTCCTTGGCTTTCCTGCTGAGTCTCCGAGGAGCTGGGGCCATCAAGGGTGAGTGCTCAGGAGGACGCAGGAGCGTCGGGCGGACCATGTGTCAACTTATGCCGCGTTTGTACAGACGCATAGAC	16	141	2
T00496	GeneExpression	GADD45GIP1	NM_052850	1,2	chr19	13065289	79M2336N52M	Minus	AATGGTACCCGAGCCTGGCGACCATGCAGGAGTCGCTGCGGGTGAAGCAGCTGGCCGAAGAGCAGAAGCGTCGGGAGAGGGAGCAGCACATCGCAGAGTGCATGGCCAAGATGCCACAGATGATTGTGAAC	16	101	1
T00497	GeneExpression	IL17F	NM_052872	1,2	chr6	52103699	85M5446N50M	Minus	AAGATACATTCACAGAAAGAGCTTCCTGCACAAAGTAAGCCACCAGCGCAACATGACAGTGAAGACCCTGCATGGCCCAGCCATGGTCAAGTACTTGCTGCTGTCGATATTGGGGCTTGCCTTTCTGAGTGAGGC	16	105	1
T00498	GeneExpression	LRG1	NM_052972	1,2	chr19	4538861	35M1030N103M	Minus	ACCATGTCCTCTTGGAGCAGACAGCGACCAAAAAGCCCAGGGGGCATTCAACCCCATGTTTCTAGAACTCTGTTCCTGCTGCTGCTGTTGGCAGCCTCAGCCTGGGGGGTCACCCTGAGCCCCAAAGACTGCCAGGTG	16	108	1
T00499	GeneExpression		ENST00000586883		chr19	4538861	35M797N97M195N44M	Minus	ACCATGTCCTCTTGGAGCAGACAGCGACCAAAAAGAATTATAATTCTCCCTGGAACAGGGGCCACTTCTGGCAGCTGTCGGGGGTGAGGGTAGAAGCTGGAAGAGGAGGAGGAAGCAACTGCCCTAGTACAGCCTCAGCCTGGGGGGTCACCCTGAGCCCCAAAGACTGCCAGGTG	16	146	2
T00500	GeneExpression	SH2D1B	NM_053282	1,2	chr1	162372559	99M9080N34M	Minus	GCAAGACTGTGAGACCTTGCTGCTCAAGGAAGGGGTGGATGGCAACTTTCTTTTAAGAGACAGCGAGTCGATACCAGGAGTCCTGTGCCTCTGTGTCTCGTTTAAAAATATTGTCTACACATACCGAATCTTC	16	103	1
T00501	GeneExpression	TAGAP	NM_054114	8,9	chr6	159459201	78M885N60M	Minus	TGCATTGGACCCAACATGCTCACCCTGGAGAATGACCAGAGCCTGTCATTTGAAGCCCAGAAGGACCTGAACAACAAGGTGAAGACACTGGTGGAATTCCTCATTGATAACTGCTTTGAAATATTTGGGGAGAACATT	16	108	1
T00502	GeneExpression	CD97	NM_078481	18,19	chr19	14517925	117M678N23M	Plus	GTCTTTGGCCTGTTCATCTTCGACGATCGGAGCTTGGTGCTGACCTATGTGTTTACCATCCTCAACTGCCTGCAGGGCGCCTTCCTCTACCTGCTGCACTGCCTGCTCAACAAGAAGGTTCGGGAAGAATACCGGAAGTG	16	110	1
T00503	GeneExpression	PTPN6	NM_080548	14,15	chr12	7069529	70M370N71M	Plus	AGTACGGGAACATCACCTATCCCCCAGCCATGAAGAATGCCCATGCCAAGGCCTCCCGCACCTCGTCCAAACACAAGGAGGATGTGTATGAGAACCTGCACACTAAGAACAAGAGGGAGGAGAAAGTGAAGAAGCAGCGGT	16	111	1
T00504	GeneExpression		NM_080549		chr12	7069529	70M227N214M	Plus	AGTACGGGAACATCACCTATCCCCCAGCCATGAAGAATGCCCATGCCAAGGCCTCCCGCACCTCGTCCAAGAGCTTGGAGTCTAGTGCAGGGACCGTGGCTGCGTCACCTGTGAGACGGGGTGGCCAGAGGGGACTGCCAGTGCCGGGTCCCCCTGTGCTGTCTCCTGACCTGCACCAACTGCCTGTACTTGCCCCCCTGCACCCGGCTGCAGACACAAGGAGGATGTGTATGAGAACCTGCACACTAAGAACAAGAGGGAGGAGAAAGTGAAGAAGCAGCGGT	16	254	2
T00505	GeneExpression	CLEC4C	NM_130441	1,2	chr12	7899992	55M1634N83M	Minus	AAGTGCAACCTCTGTCTGACCCTGCATGGTGTGCGGTGCCCTCCTGCCTCAGGCCGCGAAGAAGGATCTAAGGGCTTGGCTTGTTTGAAAGAACCACACCCCGAAAGTAACATCTTTGGAGAAAGTGATACAAGAGCT	16	108	1
T00506	GeneExpression		ENST00000354629		chr12	7899992	55M1631N86M	Minus	AAGTGCAACCTCTGTCTGACCCTGCATGGTGTGCGGTGCCCTCCTGCCTCAGGCCTAGGCGAAGAAGGATCTAAGGGCTTGGCTTGTTTGAAAGAACCACACCCCGAAAGTAACATCTTTGGAGAAAGTGATACAAGAGCT	16	111	2
T00507	GeneExpression	MADCAM1	NM_130760	4,5	chr19	501905	25M2815N101M	Plus	CAGGGAGAAGTGATCCCAACAGGCTCGTCCAAACCTGCGGGTGACCAGCTGCCCGCGGCTCTGTGGACCAGCAGTGCGGTGCTGGGACTGCTGCTCCTGGCCTTGCCCACCTATCACCTCTGGAAA	16	96	1
T00508	GeneExpression	BCL2L11	NM_138621	2,3	chr2	111881639	78M25904N62M	Plus	CACCCATGAGTTGTGACAAATCAACACAAACCCCAAGTCCTCCTTGCCAGGCCTTCAACCACTATCTCAGTGCAATGGCTTCCATGAGGCAGGCTGAACCTGCAGATATGCGCCCAGAGATATGGATCGCCCAAGAGTTG	16	110	1
T00509	GeneExpression		NM_138624		chr2	111881639	78M20348N33M5523N62M	Plus	CACCCATGAGTTGTGACAAATCAACACAAACCCCAAGTCCTCCTTGCCAGGCCTTCAACCACTATCTCAGTGCAATGGCTAACTGGGACTAGAAACAGCTCCATCACCCAGCTTCCATGAGGCAGGCTGAACCTGCAGATATGCGCCCAGAGATATGGATCGCCCAAGAGTTG	16	143	2
T00510	GeneExpression	TLR8	NM_138636	1,2	chrX	12924759	70M12334N62M	Plus	TCCTGCATAGAGGGTACCATTCTGCGCTGCTGCAAGTTACGGAATGAAAAATTAGAACAACAGAAACATGGAAAACATGTTCCTTCAGTCGTCAATGCTGACCTGCATTTTCCTGCTAATATCTGGTTCCTG	16	102	1
T00511	GeneExpression	MAPK14	NM_139012	11,12	chr6	36075297	109M751N30M	Plus	CTTGCACATGCCTACTTTGCTCAGTACCACGATCCTGATGATGAACCAGTGGCCGATCCTTATGATCAGTCCTTTGAAAGCAGGGACCTCCTTATAGATGAGTGGAAAAGCCTGACCTATGATGAAGTCATCAGCTTTG	16	109	1
T00512	GeneExpression	STAT3	NM_139276	17,18	chr17	40475613	105M1085N31M	Minus	GAACCTGGGATCAAGTGGCCGAGGTCCTGAGCTGGCAGTTCTCCTCCACCACCAAGCGAGGACTGAGCATCGAGCAGCTGACTACACTGGCAGAGAAACTCTTGGGACCTGGTGTGAATTATTCAGGGTGTCAGAT	16	106	1
T00513	GeneExpression	IGJ	NM_144646	1,2	chr4	71527885	87M4211N48M	Minus	TTTTCAGAAGAAGTGAAGTCAAGATGAAGAACCATTTGCTTTTCTGGGGAGTCCTGGCGGTTTTTATTAAGGCTGTTCATGTGAAAGCCCAAGAAGATGAAAGGATTGTTCTTGTTGACAACAAATGTAAGTGTG	16	105	1
T00514	GeneExpression		ENST00000391614		chr4	71527885	87M2277N48M1886N48M	Minus	TTTTCAGAAGAAGTGAAGTCAAGATGAAGAACCATTTGCTTTTCTGGGGAGTCCTGGCGGTTTTTATTAAGGCTGTTCATGTGAAAGGTTCAAGAGATTCTTCTGCCTCAGCCTCCCGAGTAGCTGGGATTACAGCCCAAGAAGATGAAAGGATTGTTCTTGTTGACAACAAATGTAAGTGTG	16	153	2
T00515	GeneExpression	NCR3	NM_147130	1,2	chr6	31557854	89M2552N50M	Minus	GACCTCACTGCTCAGATCCCCTTCGCCAACTGGGACATCTTCCGACATGGCCTGGATGCTGTTGCTCATCTTGATCATGGTCCATCCAGGATCCTGTGCTCTCTGGGTGTCCCAGCCCCCTGAGATTCGTACCCTGGAA	16	109	1
T00516	GeneExpression	CBLB	NM_170662	1,2	chr3	105586322	28M1144N114M	Minus	TGTCTCTGGACAGCTACGGCGCCGAAAGAACTAAAATTCCAGATGGCAAACTCAATGAATGGCAGAAACCCTGGTGGTCGAGGAGGAAATCCCCGAAAAGGTCGAATTTTGGGTATTATTGATGCTATTCAGGATGCAGTTG	16	112	1
T00517	GeneExpression	LMNA	NM_170707	1,2	chr1	156085033	33M15342N106M	Plus	AGTGCGTGAGGAGTTTAAGGAGCTGAAAGCGCGCAATACCAAGAAGGAGGGTGACCTGATAGCTGCTCAGGCTCGGCTGAAGGACCTGGAGGCTCTGCTGAACTCCAAGGAGGCCGCACTGAGCACTGCTCTCAGTGAG	16	109	1
T00518	GeneExpression	CD8A	NM_171827	4,5	chr2	87012983	23M2558N112M	Minus	AGACGTGTTTGCAAATGTCCCCGGCCTGTGGTCAAATCGGGAGACAAGCCCAGCCTTTCGGCGAGATACGTCTAACCCTGTGCAACAGCCACTACATTACTTCAAACTGAGATCCTTCCTTTTGAGGGAGCAAGT	16	105	1
T00519	GeneExpression	CD8B	NM_172213	2,3	chr2	87080147	75M4970N63M	Minus	ACAGTGGCATCTACTTCTGCATGATCGTCGGGAGCCCCGAGCTGACCTTCGGGAAGGGAACTCAGCTGAGTGTGGTTGATTTCCTTCCCACCACTGCCCAGCCCACCAAGAAGTCCACCCTCAAGAAGAGAGTGTGCC	16	108	1
T00520	None		ENST00000303432		chr2	107107615	75M4939N63M	Plus	ACAGTGGCATCTACTTCTGCATGATCGTCGGGAGCCCCGAGCTGACCTTCGGGAAGGGAACTCAGCTGAGTGTGGTTGATTTCCTTCCCACCACTGCCCAGCCCACCAAGAAGTCCACCCTCAAGAAGAGAGTGTGCC	16	108	-1
T00521	GeneExpression	NFATC1	NM_172387	9,10	chr18	77246881	57M40590N81M	Plus	TTCCTGTAACGGTCAAGCGAGAGCCTGAAGAGTTGGACCAGTTGTACCTGGATGACGTAAATGAAATAATACGAAATGACCTCTCCAGCACGAGCACCCACTCCTAGTTGCCACATTGGAGCACTCAGTTCAGCAGGG	16	108	1
T00522	GeneExpression	TIGIT	NM_173799	2,3	chr3	114014622	100M3722N39M	Plus	CTGACCGTGAACGATACAGGGGAGTACTTCTGCATCTATCACACCTACCCTGATGGGACGTACACTGGGAGAATCTTCCTGGAGGTCCTAGAAAGCTCAGTGGCTGAGCACGGTGCCAGGTTCCAGATTCCATTGCTTG	16	109	1
T00523	GeneExpression	CD86	NM_175862	2,3	chr3	121810459	39M11861N90M	Plus	TGAGTAACATTCTCTTTGTGATGGCCTTCCTGCTCTCTGGTGCTGCTCCTCTGAAGATTCAAGCTTATTTCAATGAGACTGCAGACCTGCCATGCCAATTTGCAAACTCTCAAAACCAAAGCCTGAGTG	16	99	1
T00524	None		ENST00000483949		chr3	121810459	124M11776N90M	Plus	TGAGTAACATTCTCTTTGTGATGGCCTTCCTGCTCTCTGGTAAGAACCTTTCAGCTTTGTTAAGTCCTGGAATCCTACTGTCTCCTGATGAGTCTGACCACAGCAAGCCCAGGCCTGAGACTTGGTGCTGCTCCTCTGAAGATTCAAGCTTATTTCAATGAGACTGCAGACCTGCCATGCCAATTTGCAAACTCTCAAAACCAAAGCCTGAGTG	16	184	-1
T00525	GeneExpression	TUBB	NM_178014	3,4	chr6	30690755	51M311N90M	Plus	TTCGCTCAGGTCCTTTTGGCCAGATCTTTAGACCAGACAACTTTGTATTTGGTCAGTCTGGGGCAGGTAACAACTGGGCCAAAGGCCACTACACAGAGGGCGCCGAGCTGGTTGATTCTGTCCTGGATGTGGTACGGAAGG	16	111	1
T00526	None		ENST00000435534		chr6	30690755	51M311N90M	Plus	TTCGCTCAGGTCCTTTTGGCCAGATCTTTAGACCAGACAACTTTGTATTTGGTCAGTCTGGGGCAGGTAACAACTGGGCCAAAGGCCACTACACAGAGGGCGCCGAGCTGGTTGATTCTGTCCTGGATGTGGTACGGAAGG	16	111	-1
T00527	None		ENST00000518096		chr8	30209750	141M	Plus	TTCGCTCAGGTCCTTTTGGCCAGATCTTTAGACCAGACAACTTTGTATTTGGTCAGTCTGGGGCAGGTAACAACTGGGCCAAAGGCCACTACACAGAGGGCGCCGAGCTGGTTGATTCTGTCCTGGATGTGGTACGGAAGG	16	111	-2
T00528	GeneExpression	NCAM1	NM_181351	18,19	chr11	113140998	120M1364N19M	Plus	CATCACCTGCTACTTCCTGAACAAGTGTGGCCTGTTCATGTGCATTGCGGTCAACCTGTGTGGAAAAGCCGGGCCCGGGGCCAAGGGCAAGGACATGGAGGAGGGCAAGGCCGCCTTCTCGAAAGATGAGTCCAAGGAG	16	109	1
T00529	GeneExpression	ITGA1	NM_181501	7,8	chr5	52177827	27M5793N104M	Plus	GACAGCTCTTGGAATAGACACAGCAAGAAAGGAGGCATTCACGGAAGCCCGGGGTGCCCGAAGAGGAGTTAAAAAAGTCATGGTTATTGTGACAGATGGAGAGTCTCATGACAATCATCGACTGAAGAAGG	16	101	1
T00530	GeneExpression	BTLA	NM_181780	1,2	chr3	112198559	80M19501N58M	Minus	ATTGCCTGCCATGCTTGGAACTGGGAAATTATTTTGGGTCTTCTTCTTAATCCCATATCTGGACATCTGGAACATCCATGGGAAAGAATCATGTGATGTACAGCTTTATATAAAGAGACAATCTGAACACTCCATCTT	16	108	1
T00531	GeneExpression	BAGE	NM_182482	1,2	chr21	11097565	86M1056N82M	Minus	GGAGTGTTAGGAGGGCGGCCTGAGCGGTAGGAGTGGGGCTGGAGCAGTAAGATGGCGGCCGGAGCAGTAAGATGGCGGCTGGAGTGGTTTTTCTGGCATTGTCTGCCCAGCTGCTCCAAGCCAGGCTGATGAAGGAGGAGTCCCCTGTGGTGAGCTGGAGGTTGGAGC	16	138	1
T00532	GeneExpression		NM_181704		chr21	11097565	65M1076N83M	Minus	GGAGTGTTAGGAGGGCGGCCTGAGCGGTAGGAGTGGGGCTGGAGCAGTAAGATGGCGGCCGGAGCGGTTTTTCTGGCATTGTCTGCCCAGCTGCTCCAAGCCAGGCTGATGAAGGAGGAGTCCCCTGTGGTGAGCTGGAGGTTGGAGC	16	118	2
T00533	None		ENST00000412295		chr5	180708549	65M1729N82M	Plus	GGAGTGTTAGGAGGGCGGCCTGAGCCGTAGGAGGGGGCTGGAGCAGTAACATGGCGGCCTGAGCGGTTTTTCTGGCATTGTCTGCCCAGCTGCTCCAAGCCAGGCTGATGAAGGAGGAGTCCCCTGTGGTGAGCTGGAGGTTGGAGC	16	117	-1
T00534	GeneExpression	IDO2	NM_194294	3,4	chr8	39821189	34M15363N101M	Plus	TGATGCTCACCAGCTTCAAGCTCATGTGGACAAGATGCCCCTGCTGAGCTGCCAGTTCCTGAAGGGTCACCGGGAGCAGCGCCTGGCCCACCTGGTCCTGAGCTTCCTCACCATGGGTTATGTCTGGCAGGAAGG	16	105	1
T00535	GeneExpression	CD247	NM_198053	1,2	chr1	167409941	67M77640N64M	Minus	AAGGACAAGATGAAGTGGAAGGCGCTTTTCACCGCGGCCATCCTGCAGGCACAGTTGCCGATTACAGAGGCACAGAGCTTTGGCCTGCTGGATCCCAAACTCTGCTACCTGCTGGATGGAATCCTCTTCAT	16	101	1
T00536	GeneExpression	TYROBP	NM_198125	4,5	chr19	36395421	20M2583N116M	Minus	AGACCGAGTCGCCTTATCAGGAGCTCCAGGGTCAGAGGTCGGATGTCTACAGCGACCTCAACACACAGAGGCCGTATTACAAATGAGCCCGAATCATGACAGTCAGCAACATGATACCTGGATCCAGCCATTCCTG	16	106	1
T00537	GeneExpression	HLA-F-AS1	NR_026972	3,4	chr6	29706129	54M114N85M	Minus	AAGCGACAAGGTGTGTCTGCAGCTGTGCTCACACCTGGAGGAAACCTCAATGGTCACATCCTCTTTCCTGTGTCAAGAAGCATCGTCCGGGGAGGTGAGAAGAAGACAGTCCTCCCTAGAATTGAAGAACCAGGGAGAA	16	109	1
T00538	GeneExpression		ENST00000458236		chr6	29706129	54M95N104M	Minus	AAGCGACAAGGTGTGTCTGCAGCTGTGCTCACACCTGGAGGAAACCTCAATGGTGACATGATGACCCTAGCAGCACATCCTCTTTCCTGTGTCAAGAAGCATCGTCCGGGGAGGTGAGAAGAAGACAGTCCTCCCTAGAATTGAAGAACCAGGGAGAA	16	128	2
T00539	None		NM_003189		chr1	47685487	254M	Plus	GACTGCCTGCCCCATCCAGGGAGCTGCCGCAGCTGGAGTTGGGGGAAAGCACGTCTTGCAGGAGGTCATCTGGGGGCGCGCCGCCCCCTCCCCCACCTCCACCCCCACCAGCCCCCACCACAGGGTCCTTGCCAGTCTTGGCCCGCTGGGTGCCCTCCTCCTCCTGGTCATTGAGCAGCTTGGCCAAGAAGTTGATATACTTCATGGCCAGGCGGAGGATCTCATTCTTGCTGAGCTTCTTGTCCGGGAGACGT	16	224	-1
T00540	None		NM_006769		chr1	87811929	407M	Minus	CCCTGGAATCCCTGAAAACAGGAAGTGAGCACAGAAGTTCTCAAAGGGAAGCTGACTGGTAGTTGAGATGTGCTGAGCTACACCTCTCTACATGGCTCCACGGCTATTCTCAGAGGGAGGGTCTACATCAGGCGCTTTTCTGGAACAAAATAAAATGCCATCTTAAAAAAGAAAATTTAAAATAGTAGCGTTCACACACCTGGTTTTATTAGCCTGTGATGGAAGTTGTAGTTGAAATTTGCTCACATCTAAGGAAGCTGGCAGTACAACCTCAGCCTCCAGGCCTATTTGGTTTTCCTCCTTCCAGCACTAGCTGTTATACTGCATGCTTTCCGGAGGGCAGCTCTGCGGGCAGTGCAGGCACTGTGGTGGACACTCTGCTGCCTGCAACCAGCAACTCAATGTCA	16	377	-1
T00541	None		NM_000702		chr1	160105341	52M236N41M	Plus	CTGACCCTGCTGGATGACAACTTTGCCTCCATCGTCACGGGGGTGGAGGAGGGCCGCCTGATCTTTGACAACTTGAAGAAATCCATCGCCACC	16	63	-1
T00542	None		NM_001166664		chr1	160808747	78M2534N93M	Minus	ACAGTGGCATCTACTGCCTGGAGGTCACCAGTATATCTGGAAAAGTTCAGACAGCCACGTTCCAGGTTTTTGTATTTGAATTCAGATTTTGGCCGTTTTTGGTGATCATCGTGATTCTAAGCGCACTGTTCCTTGGCACCCTTGCCTGCTTCTGTGTGTGGAGGAGAAAGA	16	141	-1
T00543	None		NM_001271037		chr1	161594392	52M5138N38M	Minus	CAGACAAACCTCTCCACCCTCAGTGACCCGGTGCAGCTAGAAGTCCATATCGGTTTGGCAGTGTCAACCATCTCATCATTCTCTCCACCT	16	60	-1
T00544	None		NM_006435		chr11	308416	23M574N105M	Plus	TAGCATTCGCCTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	98	-1
T00545	None		NR_049759		chr11	319886	23M579N100M	Minus	TAGCATTCGCCTACTCCGTGAAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCTTCATGACC	16	93	-2
T00546	None		NM_021034		chr11	319886	23M574N105M	Minus	TAGCATTCGCCTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCTTCATGACC	16	98	-3
T00547	None		ENST00000443143		chr4	66960067	128M	Plus	TAGCATTCGCCTACTCCGTGAAGTCTAGGCACAGGAAGATGGTTGGCGACCTGACTGGCGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	98	-4
T00548	None		ENST00000442064		chr7	56231057	128M	Plus	TAGCATTCGCCTACTCCATGAAGTCTAGGGACAGGAAGATGGTTGGCGACCTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGACTTTGGGCATCTTCATGACC	16	98	-5
T00549	None		ENST00000527146		chr11	308416	23M316N135M123N105M	Plus	TAGCATTCGCCTACTCCGTGAAGACTGGCACCCAGGCTCTCCCAGAAAGTGAGAAGGGAACTCACAGGTGACTTCACCCCATGGTGGGGAGAACAGCCTGTGCTGGGGCCAAGGCAGAAGGAGGATGAGCCCCGAGGCTCCTGGAGAGTCTGAGCCGGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	233	-6
T00550	None		ENST00000531688		chr11	319886	23M316N136M122N105M	Minus	TAGCATTCGCCTACTCCGTGAAGACTGGCACCCAGGCTCTCCCAGAAAGTGAGAAGGGAACTCACAGGTGACTTCACCCCATGGTGGGGAGAACAGCCTGTGCTGAGGTCAAGGCAGAAGGAGGATGAGCCCCGAGGCTCCTGGAGAGTCTGAGCCCGGTCTAGGGACAGGAAGATGGTTGGCGACGTGACCGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTCTGGGCATCTTCATGACC	16	234	-7
T00551	None		ENST00000535743		chr11	69070921	128M	Minus	TAGCATTCGCCTACTCCGTGTAGTCTAGGGACAGGAAGATGGTTGGCGACCTGACTGGGGCCCAGGCCTATGCCTCCACCGCCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	98	-8
T00552	None		ENST00000393255		chr12	31907880	128M	Plus	TAGCATTCGCCTACTCCGTGAAGTCTAGGGACAGGAAGATGGTTGGCAACGTGACTGGGGCCCAGGCCTATGCCTCCACCACCAAGTGCCTGAACATCTGGGCCCTGATTTTGGGCATCTTCATGACC	16	98	-9
T00553	None		ENST00000553227		chr12	47529317	142M	Minus	TAGCATTCGCCTACTCTGTGAAGTCTAGGACAGGAAGTCTATGGACAGGAAGATGGTTGGTGACCTGACTGGGGCCCAGGCCTGTGTCTCCACTGCCAAGTGCCTGAACATCTGGGCCCTGGCTCTGGGCATCTTCATGACC	16	112	-10
T00554	None		NM_057174		chr11	45935393	68M135N153M112N73M192N97M	Minus	CCCTGGAATCCCTGAGCAGTCCTACGTGGGGAAGCGGTCAAACCGGGTGGTGCGAACCCTCCAGAACACGCCGTCCCTGCACTCCAGGCACTGGGGAGCTCCCCAGCAGCGGGAGGGACGGCAGCAGCAGCATCACGAGGAGCTGAGTGCGACCCCCACCCCCCTGGGGCTGCAGGAGACCATCGCAGAGTTTTTGTACATTGCCCGGCCGCTGCTGCACTTGCTCAGCCTGGGCCTGTGGGGTCAGAGGTCGTGGAAACCCTGGCTCTTGGCTGGTGTTGTGGACGTGACCAGCCTGAGCCTCCTGAGTGACAGAAAGGGCCTGACCCGGAGGGAGCGGCGGGAGCTGCGGCGCCGGACCATCCTGCTGCTCTACTACCTGCTGCCCTGA	16	361	-1
T00555	None		NM_005555		chr12	52843328	27M918N215M333N61M158N96M124N90M	Minus	AACAAGTTTGCCTCCTTCATCGACAAGGTGCGGTTCCTAGAGCAGCAGAACAAGGTTCTGGACACCAAGTGGACCCTGCTGCAGGAGCAGGGCACCAAGACTGTGAGGCAGAACCTGGAGCCGTTGTTCGAGCAGTACATCAACAACCTCAGGAGGCAGCTGGACAACATCGTGGGGGAACGGGGTCGTCTGGACTCGGAGCTGAGAAACATGCAGGACCTGGTGGAGGACCTCAAGAACAAATATGAGGATGAAATCAACAAGCGCACAGCAGCAGAGAATGAATTTGTGACTCTGAAGAAGGATGTGGATGCTGCCTACATGAACAAGGTTGAACTGCAAGCCAAGGCAGACACTCTTACAGATGAGATCAACTTCCTGAGAGCCTTGTATGATGCAGAGCTGTCCCAGATGCAGACCCACATCTCAGACACATCCGTGGTGCTATCCATGGACAACAACCGCAACCTGGACCTGGATAGCATCATC	16	459	-1
T00556	None		NM_173086		chr12	52864991	27M917N215M333N61M155N96M124N90M	Minus	AACAAGTTTGCCTCCTTCATCGACAAGGTGCGGTTCCTAGAGCAGCAGAACAAGGTTCTGGACACCAAGTGGACCCTGCTGCAGGAGCAGGGCACCAAGACTGTGAGGCAGAACCTGGAGCCGTTGTTCGAGCAGTACATCAACAACCTCAGGAGGCAGCTGGACAGCATCGTCGGGGAACGGGGCCGCCTGGACTCGGAGCTGAGAAACATGCAGGACCTGGTGGAGGACCTCAAGAACAAATATGAGGATGAAATCAACAAGCGCACAGCAGCAGAGAATGAATTTGTGACTCTGAAGAAGGATGTGGATGCTGCCTACATGAACAAGGTTGAACTGCAAGCCAAGGCAGACACTCTCACAGATGAGATCAACTTCCTGAGAGCCTTGTATGATGCAGAGCTGTCCCAGATGCAGACCCACATCTCAGACACATCCGTGGTGCTATCCATGGACAACAACCGCAACCTGGACCTGGATAGCATCATC	16	459	-2
T00557	None		NM_005554		chr12	52884428	27M912N215M349N61M158N96M124N90M	Minus	AACAAGTTTGCCTCCTTCATCGACAAGGTGCGGTTCCTGGAGCAGCAGAACAAGGTTCTGGAAACAAAGTGGACCCTGCTGCAGGAGCAGGGCACCAAGACTGTGAGGCAGAACCTGGAGCCGTTGTTCGAGCAGTACATCAACAACCTCAGGAGGCAGCTGGACAGCATTGTCGGGGAACGGGGCCGCCTGGACTCAGAGCTCAGAGGCATGCAGGACCTGGTGGAGGACTTCAAGAACAAATATGAGGATGAAATCAACAAGCGCACAGCAGCAGAGAATGAATTTGTGACTCTGAAGAAGGATGTGGATGCTGCCTACATGAACAAGGTTGAACTGCAAGCCAAGGCAGACACTCTCACAGACGAGATCAACTTCCTGAGAGCCTTGTATGATGCAGAGCTGTCCCAGATGCAGACCCACATCTCAGACACATCTGTGGTGCTGTCCATGGACAACAACCGCAACCTGGACCTGGATAGCATCATC	16	459	-3
T00558	None		NM_175834		chr12	53218057	27M2157N221M1113N61M113N96M5660N90M	Minus	AACAAGTTTGCCTCCTTCATCGACAAGGTGCGGTTCCTGGAGCAACAGAATAAGGTGCTGGAGACCAAGTGGGCACTGCTGCAGGAGCAGGGCCAGAACTTGGGTGTCACCAGGAACAACCTGGAGCCCCTCTTTGAGGCCTACCTGGGTAGCATGCGGAGCACGCTGGACAGACTTCAGAGCGAGCGGGGGAGGCTGGACTCAGAGCTCAGGAACGTGCAGGACCTTGTGGAGGACTTCAAGAACAAGTACGAGGATGAAATCAACAAGCACACTGCTGCAGAGAACGAGTTTGTGGTGCTCAAGAAGGATGTGGATGCAGCATACATGGGCCGGATGGATCTGCATGGCAAAGTGGGCACCTTGACCCAGGAGATTGACTTCCTGCAGCAACTCTATGAAATGGAGCTGAGCCAAGTGCAGACCCACGTGTCTAACACCAATGTGGTGCTGTCCATGGACAACAACCGCAACCTGGACCTGGATAGCATCATC	16	465	-4
T00559	None		NR_024563		chr12	132856517	243M	Plus	CTGGATTCCCTTCCTGAATGCCCAGTGTCTGCTAGGTCTCCTGGATCCACTTCCTGGATGCCCAGTGTCTGCCAAATCTCCTGAATTCACTTCCTGGATGCCCAGTGTCCACCAGGTCTCCTGGATTCTGCCTGTGTCCACGTGAGGGCACCATCAATTTCCTGCAAGGATCCTGACAGTCAAGGTACATCTAACCTGAGAGCAGGCAGGGGCTGGACTATCCCCTAGATCCAGCCATTCCTG	16	213	-1
T00560	None		NM_144985		chr14	23518398	21M83N112M351N87M	Minus	CCCTCTGCAGCTCCTGGCCAGCTGATTCAGGTCATCCGGGCCCTGGACAGAGATGAAGTTGGCAACAGTAGCCATGTCTCCTTTCAAGGTCCTCTGGGCCCTGATGCCAACTTTACTGTCCAGGACAACCGAGATGGCTCCGCCAGCCTGCTGCTGCCCTCCCGCCCTGCTCCACCCCGCCATGCCCCCTACTTGGTTCCCATAGAACTGTGGGACTGGG	16	190	-1
T00561	None		NM_005132		chr14	24646566	99M104N67M383N132M332N50M167N77M81N24M	Minus	CAGCGGCTTTCTCCTCAGGCAGCTCTCGCCTGAGGGCTTTTGGGGGTGGCTGGGCACAATGGGTCCAGAGACCCAGTAGTTCAGGGGGTAGCCAGCCAGAGAGAGTTGGGGTTCTGAACAACTCCGCAGGGCCTCTGATGGTCCTCTCGGGCGGCTGCACCATAGGACATTCCCAGCAGTGGGCTCTGGTTTGCAGTTGTTCCTGGAATTTCTCCGGGGAGATCTGAGTCTCCTTGTCCCAGAACAGTAACCGGCGACGACGGCGGCGGCGAGGAGGTGGGGGGACTGGGGGCCTCCTCTCTGGGCTGGGTGGGGCTGGCAGACGCAGCTCCTCCGGGGGGGTCACCTCCATGAGTAGGGCCCCAGGTTCCCAGCCTGTCAGCCTCAGCTCCTCAGGACCCAGTGCCTCTCCTATTCCTTCCACCTCTGCAGGAGCTGGAGGTTGGAGC	16	419	-1
T00562	None		NM_020857		chr15	41194951	131M	Minus	CCCTCTGCAGCTCCTGGATGTGGTGGTTGTAGGCCTTAAGTGAGCTGCAGATCGCCTCCTTGAAGTGGTCGATGGTGACGAAATCAGGAAAGAAGGGCAGCACATCCTCAATCTTGAGCATGGGGCAGCTC	16	101	-1
T00563	None		NM_015286		chr15	99645424	107M	Plus	CAGACGAGCACTGAGAAGGCCGAGCTCCAGGAGCTCAACGCCCGGCTCTATGACTACGTGTGTCGGGTGCGGGAGCTGGAGCGCGAAAACCTACTCCTGGAGGGGAA	16	77	-1
T00564	None		NM_018231		chr16	58712238	134M221N141M	Minus	GAGGCTCTACCAGGAGGTGGTATGGGCTGTGTGTGGCAAGCTGACAGGTGTGCTATGTGAGGTGGCCATCGCTGTCTACACCTTTGGCACCTGCATTGCCTTCCTAATCATCATTGGCGACCAGCAGGACAAGATTATAGCTGTGATGGCGAAAGAGCCGGAGGGGGCCAGCGGCCCTTGGTACACAGACCGCAAGTTCACCATCAGCCTCACTGCCTTCCTCTTCATCCTGCCCCTCTCCATCCCCAGGGAGATTGGTTTCCAGAAATATGTCA	16	245	-1
T00565	None		NM_152456		chr16	70680641	204M	Minus	TGTCCTCGTCCTCCTGAGAGCTCAGGCGCCGTCCCCAGCAGTGTGTCCACAGAGGCCTAAGCACGGCCTACATGGCCTCGGGGCAGCAGAGGTGGTCACTCAGTCAGGGAAGGGCTGGCCCTGGAGGAGTGGCTGGGCTGCGGGAGTGAGCAGGTGCCCCAAGGGCAGCAGCTGCCCTTATCTGCCCGGCAGCGCGGAGGACAG	16	174	-1
T00566	None		NM_002988		chr17	34397862	57M392N68M	Plus	AAAGTTCATAGTTGACTATTCTGAAACCAGCCCCCAGTGCCCCAAGCCAGGTGTCATCCTCCTAACCAAGAGAGGCCGGCAGATCTGTGCTGACCCCAATAAGAAGTGGGTCCAGAAATATGTCA	16	95	-1
T00567	None		NM_002983		chr17	34416041	57M420N68M	Minus	AAAGTTCATAGTTGACTACTTTGAGACGAGCAGCCAGTGCTCCAAGCCCGGTGTCATCTTCCTAACCAAGCGAAGCCGGCAGGTCTGTGCTGACCCCAGTGAGGAGTGGGTCCAGAAATATGTCA	16	95	-2
T00568	None		NM_001145365		chr17	47376256	43M470N145M12387N31M	Minus	GCACTCCTTGGAGCATTCTGGAGAGAAGCCCTTTAGATGCGAGAACTGTGACGAAAGGTTTCAGTACAAGTACCAGCTACGCTCCCACATGAGCATTCATATTGGGCACAAACAGTTCATGTGCCAGTGGTGTGGCAAGGATTTCAACATGAAGCAGTACTTCGACGAACACATGAAAACACACACTGGAGAGAAACCCTTTATCTGTGAAATCTGTGG	16	189	-1
T00569	None		NM_199242		chr17	73826730	13M436N72M73N89M	Plus	CCCTCTGCAGCTCCTGGAAGGTGGCAGTGTGCAGGGCCTTGGGTGGCAGGCCACAGCCCTCAGCGTGGAAGCAGATCTCCAGGTTCTGCAGGGCAATCTTCAGCCTGTTGGAAGCCAGGGATGAGCTGCGCTGGGAGGCGGCCGCCTCCACCAGCACTGTGACAGAGTGGGTCC	16	144	-1
T00570	None		NM_001039360		chr18	45567049	422M	Plus	TGTCCTCGTCCTCCTTGTCATCCTCCTCCCCCCCGTCCCCCCCAGGCTCCATGATCTCCAGGCACACGTTCACGATGCACTGGATCTCCAGCATCCTGGCTGCGTTGAGGATGTGCTTGACATTGCCAGCGGTGATGGTGAGCGTGGAGGTGTAGGCGAACTCCAGGATAGCAGCCAGAGCCTCAGGCTGGACAAAGTCGATCTCATAGACGTAGGGCTGGCTGGCTAGGGTGCCGGCTGTGAAAAGCTTCTTGAAGTACTTGCTGCAGGCAGCCAGGACGGAGCGGTGGGTCCGATACTCCTGCTCCTGCACCACCAGGAGCACGTCACACAGCAGGCCATCGTGCCGTTGCTCATTGAGGCTGCACAGGACCTCACTGCTGTGGTTGGGGAAGGGAATGCCAATGAGCAACTCAATGTCA	16	392	-1
T00571	None		NM_001784		chr19	14517925	102M	Plus	GTCTTTGGCCTGTTCATCTTCGACGATCGGAGCTTGGTGCTGACCTATGTGTTTACCATCCTCAACTGCCTGCAGGGCGCCTTCCTCTACCTGCTGCCCTGA	16	72	-1
T00572	None		NM_015260		chr19	16942338	121M10120N182M	Plus	CCAGCTCTTCACCGAGCACCCTGACCTCATTGTTGGATTCAACGCTTTTCTTCCCCTCGGATATAGAATAGACATTCCCAAGAATGGCAAGTTAAACATACAGTCGCCTCTGACAAGCCAGGAGAATTCGCACAACCACGGGGACGGTGCAGAGGACTTCAAGCAGCAGGTGCCGTATAAAGAGGACAAACCCCAGGTGCCCCTGGAGTCCGATTCCGTGGAATTCAACAACGCCATCAGCTATGTGAATAAGATTAAAACCCGCTTCCTAGACCACCCAGAAATCTACAGGTCATTCTTGGG	16	273	-1
T00573	None		NM_007186		chr20	34091390	283M	Plus	GCGTGATGAGGAGAAGGAGGTGGAATGTCAGCAGGAGCATATCCATGAACTCCAGGAGCTCAAAGACCAGCTGGAGCAGCAGCTCCAGGGCCTGCACAGGAAGGTAGGTGAGACCAGCCTCCTCCTGTCCCAGCGAGAGCAGGAAATAGTGGTCCTGCAGCAGCAACTGCAGGAAGCCAGGGAACAAGGGGAGCTGAAGGAGCAGTCACTTCAGAGTCAACTGGATGAGGCCCAGAGAGCCCTAGCCCAGAGGGACCAGGAACTGGAGGCTCTGCAGCCTGCA	16	253	-1
T00574	None		NM_001009880		chr22	45588874	384M	Minus	GACTGCCTGCCCCATGTCCTAATATGGTGGTTTTAAGTTGTTGGCCAAAATCCTTTAAAGACATACGAAACATCTGCCAACTTTTTAGCGAACTTAACAGGTTTCACTGACGTTTTCCTCAATTTTTGAATTTAGGTGGGATTTGCTTTCATGTCCTGTTTCAAAAACCAAGTGTCTCTTGACAGCCCACTGGTTCTTCCTGTCCTCTTGCTCTAGTCTGTATCAGAAAGCAGAATGACTGTACTTTTGTTTTACAAACAACCACCTGATAGGACGGACACTCCACGAGATAAGGAAAGGCACGTGCCCTTGAGCTTGAATGGAAGCAGCCTCTGGAGGGGGCAGCCACTGCCCTTCGAGGGAGAGCAGCTCATCAGCAGTGAC	16	354	-1
T00575	None		NM_001001694		chr22	50433005	503M	Minus	GTCCTTGGGTGCTGAGCTTCACTGGGGCACCCGCCCCACTCGGACCCCTCCAGAGGGTCTCAGCTTCCCCAGATCCCAGCCCCACTCACCCAGCAACGGTCAGTCACTTCCTGTGGTCTCAGAGGCCACCTGCCTGGGGGCCACCTGCTGGGATGTGCGGTTCTCAGACATTCCAAGTGGCACATCCAGGTCCCAGCCAGGGGTGCCCAGCAGTGGCCTGTGCAGTGGGCCATGGGGTCGGCCCTTGAAGACTTCTCGTGTGGGTCACGTAGGCTCTCCGGCTTCCCCGCTGAGCCACCCTCTGGAGCCTGGACATCGTCTCACCTGAGTGCTGTGCAGGACCACATGCCCAGCCTGTCCCAGCGGTGGTCGCACCCCATCTGCAGATGCACTCCCACCGCAGTCTGGGCCCAGGCTGCCCTCTTCCAGCTGGCCGTGGGCCGCTGGGCCTTCTTTTCCCTCCTGCAACAGAGGCTGCTATGTCCCATAGACTGGAGAAAGGA	16	473	-1
T00576	None		NM_001009877		chr5	881269	45M653N116M2521N133M2755N29M	Minus	TTGGCGAGGAAGATCCTTCACGCAGGCTTTAAGATGATGAGCAAACAGGCAGCTCTTTTGGGCAATGAAGATACAGCTGTTGAGGAACCTGTCCCTGAAGTTGTACCAGTACAAGTAGAAACTGCCAAGAAATCCAAAAAGCCGAGTAGAGAAGTTATCAGCTGCATGTTTGAGCCTGAAGGGAATGCCTGCAGCTTGACGGACAGTACCGCAGAGGAGCACGTGCTGGCGCTGGTGGAGCACGCAGCTGACGAAGCTCGGGACAGGATCAACCGGTTCCTCCCAGGCGGCAAGATGGGCTATCTGAAGAGGAACGGTGCCTG	16	293	-1
T00577	None		NR_027633		chr5	881269	45M593N176M2521N133M2755N29M	Minus	TTGGCGAGGAAGATCCTTCACGCAGGCTTTAAGATGATGAGCAAAGAGCGGCTGTTAGCTTTGAAGCGCAGCATGTCGTTTATGCAGGACATGGATTTTTCTCAGCAGGCAGCTCTTTTGGGCAATGAAGATACAGCTGTTGAGGAACCTGTCCCTGAAGTTGTACCAGTACAAGTAGAAACTGCCAAGAAATCCAAAAAGCCGAGTAGAGAAGTTATCAGCTGCATGTTTGAGCCTGAAGGGAATGCCTGCAGCTTGACGGACAGTACCGCAGAGGAGCACGTGCTGGCGCTGGTGGAGCACGCAGCTGACGAAGCTCGGGACAGGATCAACCGGTTCCTCCCAGGCGGCAAGATGGGCTATCTGAAGAGGAACGGTGCCTG	16	353	-2
T00578	None		ENST00000490814		chr5	881269	45M653N116M2521N133M487N100M2168N29M	Minus	TTGGCGAGGAAGATCCTTCACGCAGGCTTTAAGATGATGAGCAAACAGGCAGCTCTTTTGGGCAATGAAGATACAGCTGTTGAGGAACCTGTCCCTGAAGTTGTACCAGTACAAGTAGAAACTGCCAAGAAATCCAAAAAGCCGAGTAGAGAAGTTATCAGCTGCATGTTTGAGCCTGAAGGGAATGCCTGCAGCTTGACGGACAGTACCGCAGAGGAGCACGTGCTGGCGCTGGTGGAGCACGCAGCTGACGAAGCTCGGGACAGGATCAACCGGTTCCTCCCAGGCGGCAAGGAGACGTTCTAGACCCAGTGTCTTCAGTGGAAACAGAGCACAGGCTGTCTGCAGTCTCAGGCTTCCTAGCAGCCCTGATAAGAGAAGTAGAGCAATGCAGATGGGCTATCTGAAGAGGAACGGTGCCTG	16	393	-3
T00579	None		NM_178140		chr5	31799331	265M	Minus	GGTGTCCCCCAACTCCTTGGTGAGGTACACAGTACAGATCTCCATTTCGGGGGGGCTGTGATCAGGTGGGACCGTACTCTCATCCACAGCAAAGTTCAGCTGGATGTACTCCTGCAGCTTCTGGATGGCCGCCTGGCAGAGCCGCTGCTCCGGCCCATCCCCACCTTCCTGCAGGCTGTTCTGCAGCCACTGGTAGAGGAGGGGCAGGTGCAGCACGGCATTGTCCTGGGTGATGGGCATGGTGCTCACTCCCAGACACCTGCAT	16	235	-1
T00580	None		NR_027822		chr6	30227764	98M312N15M	Plus	GTATTGGGACCAGGAGACACGGAACGCCAAGGGCCACGCGCAGATTTACCGAGTGAACCTGCGGACCCTGCTCCGCTATTACAACCAGAGCGAGGCCGGTATGAACAGTATGC	16	83	-1
T00581	None		NM_005516		chr6	30457675	98M244N79M	Plus	GTATTGGGACCAGGAGACACGGAGCGCCAGGGACACCGCACAGATTTTCCGAGTGAATCTGCGGACGCTGCGCGGCTACTACAATCAGAGCGAGGCCGGGTCTCACACCCTGCAGTGGATGCATGGCTGCGAGCTGGGGCCCGACGGGCGCTTCCTCCGCGGGTATGAACAGTATGC	16	147	-2
T00582	None		ENST00000420110		chr6	30227764	98M248N79M	Plus	GTATTGGGACCAGGAGACACGGAACGCCAAGGGCCACGCGCAGATTTACCGAGTGAACCTGCGGACCCTGCTCCGCTATTACAACCAGAGCGAGGCCGGGTTCTCACACCATCCAGAGGAAGCATGGCTGCGACGTGGGCCCGACAGGCGCCTCCTCCGCAGGTATGAACAGTATGC	16	147	-3
T00583	None		ENST00000484194		chr6	30457675	421M	Plus	GTATTGGGACCAGGAGACACGGAGCGCCAGGGACACCGCACAGATTTTCCGAGTGAATCTGCGGACGCTGCGCGGCTACTACAATCAGAGCGAGGCCGGTGAGTGACCCCGGCCAGGGGAGCAGGTCACGACCCCTCCCCATCCCCCACGGACGGCGCGGGTCCCCTCGAATCTTCGGGTCCCAGATTCACCCCAAGGCTGCGGAACCCGCCCAGACCCTAGACCGGGGAGAGTCTCAGGCGCCTTTACCCGGTTCTTTTTCAGTTTAGGCCAAAATGCCCACAGGGTGGTGGCGACGGGGGCGGGGCTTGGTGGGCGGGACTGACTAAGGGGCGGGGCCAGGGTCTCACACCCTGCAGTGGATGCATGGCTGCGAGCTGGGGCCCGACGGGCGCTTCCTCCGCGGGTATGAACAGTATGC	16	391	-4
T00584	None		NM_002117_2		chr6	31238237	98M250N276M587N26M	Minus	GTATTGGGACCAGGAGACACAGAAGTACAAGCGCCAGGCACAGGCTGACCGAGTGAGCCTGCGGAACCTGCGCGGCTACTACAACCAGAGCGAGGACGGGTCTCACACCCTCCAGAGGATGTCTGGCTGCGACCTGGGGCCCGACGGGCGCCTCCTCCGCGGGTATGACCAGTCCGCCTACGACGGCAAGGATTACATCGCCCTGAACGAGGACCTGCGCTCCTGGACCGCCGCGGACACCGCGGCTCAGATCACCCAGCGCAAGTTGGAGGCGGCCCGTGCGGCGGAGCAGCTGAGAGCCTACCTGGAGGGCACGTGCGTGGAGTGGCTCCGCAGATACCTGGAGAACGGGAAGGAGACGCTGCAGCGCGCAGAACCCCCAAAGACACACGTGACTCAC	16	370	-1
T00585	None		ENST00000478519		chr6	29795996	98M1101N26M	Plus	GTATTGGGACCAGGAGACACGGAACACCAAGGCCCACGCACAGACTGACAGAATGAACCTGCAGACCCTGCGCGGCTACTACAACCAGAGCGAGGCCAACCCCCCCAAGACACACGTGACTCAC	16	94	-2
T00586	None		ENST00000376237		chr6	31238237	98M267N259M587N26M	Minus	GTATTGGGACCAGGAGACACAGAAGTACAAGCGCCAGGCACAGGCTGACCGAGTGAGCCTGCGGAACCTGCGCGGCTACTACAACCAGAGCGAGGACGAGGATGTCTGGCTGCGACCTGGGGCCCGACGGGCGCCTCCTCCGCGGGTATGACCAGTCCGCCTACGACGGCAAGGATTACATCGCCCTGAACGAGGACCTGCGCTCCTGGACCGCCGCGGACACCGCGGCTCAGATCACCCAGCGCAAGTTGGAGGCGGCCCGTGCGGCGGAGCAGCTGAGAGCCTACCTGGAGGGCACGTGCGTGGAGTGGCTCCGCAGATACCTGGAGAACGGGAAGGAGACGCTGCAGCGCGCAGAACCCCCAAAGACACACGTGACTCAC	16	353	-3
T00587	None		NM_005514_1		chr6	31323344	236M574N26M	Minus	GCCGGACGGGTTCCTCCTCCGCGGGCATGACCAGTACGCCTACGACGGCAAGGATTACATCGCCCTGAACGAGGACCTGCGCTCCTGGACCGCCGCGGACACGGCGGCTCAGATCACCCAGCGCAAGTGGGAGGCGGCCCGTGAGGCGGAGCAGCGGAGAGCCTACCTGGAGGGCGAGTGCGTGGAGTGGCTCCGCAGATACCTGGAGAACGGGAAGGACAAGCTGGAGCGCGCTGACCCCCCAAAGACACACGTGACTCAC	16	232	-1
T00588	None		NM_182899		chr7	28843944	196M4664N228M8656N34M	Plus	CCTGCATCAGCACCAGACACTGCCACCCCATCACCCTTACCCACACCAGCACCAGCACCCAGCACACCATCCTCACCCTCAACCCCATCACCAGCAGAACCATCCACATCACCACTCCCATTCCCACCTTCATGCACACCCAGCACATCACCAGACCTCGCCACATCCGCCCCTGCACACCGGCAACCAAGCACAGGTTTCACCAGCAACACAACAGATGCAGCCAACCCAGACAATACAGCCACCCCAGCCCACAGGGGGGCGCCGGCGAAGGGTGGTAGACGAGGATCCGGACGAGAGGCGGCGGAAATTTCTGGAACGGAACCGGGCAGCTGCCACCCGCTGCAGACAGAAGAGGAAGGTCTGGGTGATGTCATTGGAAAAGAAAGCAGAAGAACTCACCCAGACAAACATGCAGCTTCAGAATGAAGTGTCTATGTTGAAAATCGAGGTGGCCC	16	428	-1
T00589	None		NR_003187		chr7	74578714	31M1755N76M99N166M1357N56M2104N111M	Minus	CCAGCTCTTCACCGAGATCTACGAGTTCCATAAAACCTTAAAAGAAATGTTCCCTATTGAGGCAGGGGCGATCAATCCAGAGAACAGGATCATCCCCCACCTCCCAGCTCCCAAGTGGTTTGACGGGCAGCGGGCCGCCGAGAACCACCAGGGCACACTTACCGAGTACTGCAGCACGCTCATGAGCCTGCCCACCAAGATCTCCCGCTGTCCCCACCTCCTTGACTTCTTCAAGGTGCGCCCTGATGACCTCAAGCTCCCCACAGACAACCAGACAAAAAAGCCAGAGACATACTTGATGCCCAAAGATGGCAAGAGTACCGCGACAGACATCACCGGCCCCATCATCCTGCAGACGTACCGCGCCATTGCCGACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	410	-1
T00590	None		ENST00000536284		chr7	74578714	31M3453N56M2104N111M	Minus	CCAGCTCTTCACCGAGATCTACGAGTTCCATGACAAAAAAGCCAGAGACATACTTGATGCCCAAAGATGGCAAGAGTACCGCGACAGACATCACCGGCCCCATCATCCTGCAGACGTACCGCGCCATTGCCGACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	168	-2
T00591	None		ENST00000419670		chr7	74578714	31M1930N166M1357N56M2104N111M	Minus	CCAGCTCTTCACCGAGATCTACGAGTTCCATCTCCCAAGTGGTTTGACGGGCAGCGGGCCGCCGAGAACCACCAGGGCACACTTACCGAGTACTGCAGCACGCTCATGAGCCTGCCCACCAAGATCTCCCGCTGTCCCCACCTCCTTGACTTCTTCAAGGTGCGCCCTGATGACCTCAAGCTCCCCACAGACAACCAGACAAAAAAGCCAGAGACATACTTGATGCCCAAAGATGGCAAGAGTACCGCGACAGACATCACCGGCCCCATCATCCTGCAGACGTACCGCGCCATTGCCGACTACGAGAAGACCTCGGGCTCCGAGATGGCTCTGTCCACGGGGGACGTGGTGGAGGTCGTAGAGA	16	334	-3
T00592	None		NM_001276260		chr9	116299043	94M	Plus	CACGCTCCGTTTCTCTATTTTCCCTGACGTCAGAAGGCAGAGTGCTTATTCACTTTGGAAGCGCACTCGCAGGAGCAGAAGAAGAGAGTGTGCC	16	64	-1
T00593	None		NM_153710		chr9	136253270	63M1977N71M1076N40M	Plus	GGGCTCAGCTTTCAGGAGGTCATTGAGGATAAGAGGAAGGCAAAGAAAATCATTGACTCTGAGTGGATGCAGAATGTGCTGGGCCAGGTGCTGGACGCGCTGGAATACCTGCACCATTTGGACATCATCCACAGGAATCTCAAACCCTCCAACATCATCCTCATCAGCAGTGAC	16	144	-1
T00594	None		NM_130777_1		chrX	52380412	76M471N106M1871N126M2899N51M	Minus	TTGGCGAGGAAGATCAACATATAGGCCTAGGCCAAGAAGAAGTTTACAGCCTCCTGAGCTGATTGGGGCTATGCTTGAACCCACTGATGAAGAGCCTAAAGAAGAGAAACCACCCACTAAAAGTCGGAATCCTACACCTGATCAGAAGAGAGAAGATGATCAGGGTGCAGCTGAGATTCAAGTGCCTGACCTGGAAGCCGATCTCCAGGAGCTATGTCAGACAAAGACTGGGGATGGATGTGAAGGTGGTACTGATGTCAAGGGGAAGATTCTACCAAAAGCAGAGCACTTTAAAATGCCAGAAGCAGGTGAAGGGAAATCACAGGTTTAAAGGAAGATAAGCTGAAACAACGCAAGCT	16	329	-1
T00595	None		NM_130777		chrX	52113163	76M471N106M1871N126M2899N51M	Plus	TTGGCGAGGAAGATCAACATATAGGCCTAGGCCAAGAAGAAGTTTACAGCCTCCTGAGCTGATTGGGGCTATGCTTGAACCCACTGATGAAGAGCCTAAAGAAGAGAAACCACCCACTAAAAGTCGGAATCCTACACCTGATCAGAAGAGAGAAGATGATCAGGGTGCAGCTGAGATTCAAGTGCCTGACCTGGAAGCCGATCTCCAGGAGCTATGTCAGACAAAGACTGGGGATGGATGTGAAGGTGGTACTGATGTCAAGGGGAAGATTCTACCAAAAGCAGAGCACTTTAAAATGCCAGAAGCAGGTGAAGGGAAATCACAGGTTTAAAGGAAGATAAGCTGAAACAACGCAAGCT	16	329	-1
T00596	None		NM_130777_1		chrX	52380412	76M471N106M1871N126M2899N51M	Minus	TTGGCGAGGAAGATCAACATATAGGCCTAGGCCAAGAAGAAGTTTACAGCCTCCTGAGCTGATTGGGGCTATGCTTGAACCCACTGATGAAGAGCCTAAAGAAGAGAAACCACCCACTAAAAGTCGGAATCCTACACCTGATCAGAAGAGAGAAGATGATCAGGGTGCAGCTGAGATTCAAGTGCCTGACCTGGAAGCCGATCTCCAGGAGCTATGTCAGACAAAGACTGGGGATGGATGTGAAGGTGGTACTGATGTCAAGGGGAAGATTCTACCAAAAGCAGAGCACTTTAAAATGCCAGAAGCAGGTGAAGGGAAATCACAGGTTTAAAGGAAGATAAGCTGAAACAACGCAAGCT	16	329	-2
T00597	None		NM_001011548		chrX	151081373	69M10483N61M	Plus	GCTTCTGCGTCTGACTCGCAGCTTGAGACTGGCGGAGGGAAGCCCGCCCAGGCTCTATAAGGAGACAAGGTTCTGAGCAGACAGGCCAACCGGAGGACAGGATTCCCTGGAGGCCACAGAGGAGCACCAA	16	100	-1
T00598	None		NM_001327_1		chrX	153846075	62M671N135M239N81M	Minus	TCAGGGCTGAATGGATGCTGCAGATGCGGGGCCAGGGGGCCGGAGAGCCGCCTGCTTGAGTTCTACCTCGCCATGCCTTTCGCGACACCCATGGAAGCAGAGCTGGCCCGCAGGAGCCTGGCCCAGGATGCCCCACCGCTTCCCGTGCCAGGGGTGCTTCTGAAGGAGTTCACTGTGTCCGGCAACATACTGACTATCCGACTGACTGCTGCAGACCACCGCCAACTGCAGCTCTCCATCAGCTCCTGTCTCCAGCAGCTTTCCCTGTTGATGTGGAT	16	248	-1
T00599	None		ENST00000447632		chr1	51768037	121M3184N100M830N66M1888N109M510N68M89N52M	Minus	CTCACACCTGCAGCTGCCCACCTGGGCCAGGCCGTCAGCATCTTTTCCTCCTGCAGGACGAGAACATGGTGAGCTTCATCAAAGGCGGCATCAAAGTTCGAAACAGCTACCAGACCTACAAGGAGCTGGACAGCCTTGTTCAGTCCTCACAATACTGCAAGGGTGAGAACCACCCGCACTTTGAAGGAGGAGTGAAGCTTGGTGTAGGGGCCTTCAACCTGACACTGTCCATGCTTCCTACTAGGATCCTGAGGCTGTTGGAGTTTGTGGGGTTTTCAGGAAACAAGGACTATGGGCTGCTGCAGCTGGAGGAGGGAGCGTCAGGGCACAGCTTCCGCTCTGTGCTCTGTGTCATGCTCCTGCTGTGCTACCACACCTTCCTCACCTTCGTGCTCGGTACTGGGAACGTCAACATCGAGGAGGCCGAGAAGCTCTTGAAGCCCTACCTGAACCGGTACCCTAAGGGTGCCATCTTCCTGTTCTTTGCAGGGAGGATTGAAGTCATTAAAGGCAGCG	16	486	-1
T00600	None		ENST00000602529		chr1	228463118	104M	Plus	CCCTCTGCAGCTCCTGCCAGTGCTACTAGTGGGGATCACGTCTAGGATTTCGAGGCACAAGGGCCTGGCGTCTTGTTCAGAGCAGGGGAGCTGGAGGTTGGAGC	16	74	-1
T00601	None		ENST00000478754		chr2	3265904	227M262N102M56719N5M	Minus	CCGTGATGCTGGTGACAATGACAGCTCCCATCGAGTGCTCATGTGCCAGGCACGGGGATCGGCGCTTTCTGGGAATGATCAAGTTGAGTCCTCTGTGCCATTGGCCTTTTCCCCTGAGGGAGTTGTTGCAATGACCTGCCGGGCCAGCAGCGCTAATTAGGAGCACACAGCGCACTTCCAGAGCACCTGACCTACAGCTACAAGGCTTCAAGGATGCTGCTTCTGAGGAGACATCATAGAATCGTTTGGCATTCTTCCTGTAGCTCAGAGTCCCACGATTGTCTTTGTAAACACGTTGCACCAGGTCTTCTTCAGGGGACAGCGCGGAGGACAG	16	304	-1
T00602	None		ENST00000481708		chr2	17862394	518M	Minus	ACTGACAGGCTGTTGATTCCCTCATCTCTCTGTCCCCTTGGGTCTCCCTATTCCCTGAGACACAGCAATATTGAAATTAGGCTAGTTAATAGCCTTACAGTGACCTCTGAGTGTCCAAGTGAAAGGAAGAGTAGGATTTCTATCACTTTAAATCAAAAGCTAGAAATGATTAAGCTTAGTGAGGAAGGTATGTCAAAAGCCAAGATAAGCCAAAAGCTAGACCTCTTGTGCCAGTTAGCCAAGTTGTAAATGCAAAGGAAAAGTTCTTGAAGGAAATTAAAAGTGCTATTCCAGTGAATACACTAATGATAAGAAAATTAAACAGCCTTATTGTTGATATGAAGAAAGTTCCAATGGTCTGGATAGAAGATCAAAGCAGCTACAACATTCCCTTAAGTCAAAACCTAATCCAGAGCAATGCCTTAACTCTCCAATTCGATGAAGGCTGAGAAAGGTGAGGAAGCTGCAGAAGAAAAGTATGACGCTAGCAGAGGTTTGTTCATGAGGTTGAAGGACCC	16	488	-1
T00603	None		ENST00000433673		chr2	128156334	119M	Minus	AACCCGGCTACTTGGGAGGCTGAGGCAGGAGAATCACTTGAACCCGGGAGGCGGAGGTTGCAGTGAGCCAAAATTGTGCCACTGCACTCCAGCCTGGGCAACAGAGTGAGACTGTGCCA	16	89	-1
T00604	None		ENST00000511453		chr4	23057922	119M	Minus	AACCCGGCTACTTGGAAGGCTGAGGGAGGAGAATTGCTTGAACCCGGGAGGTAGAGGTTGCGGTGAGCCAAAATCATGCCACTGAACTCCAGCCTGGGCGACAGAGTGAGACTGTGCCA	16	89	-2
T00605	None		ENST00000487841		chr6	166737374	119M	Plus	AACCCGGCTACTTGGAAGGCTGAGGCACGAGAATCACTTGAACCCGGGAGGCAGAGGTTGCAGTGAGCCAAGATAATGCCACTGCACTCCAGCCTGGGTGACAGAGTGAGACTGTGCCA	16	89	-3
T00606	None		ENST00000473753		chr12	28317007	117M3352N2M	Plus	AACCCGGCTACTTGGGAGGCTGAGGCAGGAGAATTGCTTGAACCCATGAGGCAGAGGTTGCAGTGAGCCGAGATCACACCACTGCACTCCAGATTGGGTAAGAGAGTGAGACTGTGCCA	16	89	-4
T00607	None		ENST00000569553		chr16	46992571	119M	Plus	AACCCGGCTACTTGGGTGGCTAAGGCATGAGAATCACTTGAACCTGGGAGGCGGGGGGTACAGTGAGCCGAGACTACACCACTGCACTCCAGCTTGGGTGACACAGTGAGACTGTGCCA	16	89	-5
T00608	None		ENST00000534927		chr16	57109845	119M	Minus	AACCCGGCTACTTGGGCGGCTGAGGCACCAGAATCGCTTGAACCCAGGAGGCAGAGGTTGCAGTGAAGTGAGATCATGCCACTGCACTCCAGCCTGGGCGACAGAGTGAGACTGTGCCA	16	89	-6
T00609	None		ENST00000533107		chr19	1799343	420M	Plus	AACCCGGCTACTTGGGAGGCTGAGGCGGGAGAATCAACCCAGGAGGCGGAGGTTTCAGTGAGCAGAGATCGCACCACTGCACTCCAGCCTGGGCAACGAGAGCAAAACTCCGTCTCAGAGAGAAAAAAAAAAAAAAAGTCGGCCGGGCGTGGTGGCTCACGCCTGTAATCCCAGCACTTTGGGAGGCCGAGGCAGGTGGATCGCCGGAGGCCAGGAGTTCGAGACCAGCATGGCCAACATGGTGAAACCCCATCTCTGCTAAAAATACAAAAAAATTAGGTGTGGTGGCAGGTGCCTGTAATCCCAGCTACTCGGGAGGCTGAGCCAGGAGAATCGCTTGAACCTGGGAGGTGGAGATTGCAGTGAGCCAAGATTGCACCACTGCATTCCTGCCTGGGTAGACAGAGTGAGACTGTGCCA	16	390	-7
T00610	None		ENST00000296575		chr4	145662575	95M	Minus	AACCCGGCTACTTGGGAGGCTGAGGCAGGAGAATTGCTTGAACCCGGGAGGCGGAGGTTGTAGTGAGCTGAGATTGTGCTGCTCTGCAGCCTGCA	16	65	-1
T00611	None		ENST00000502799		chr4	844302	504M	Minus	GACTGGCAAGAAAGGGCCAAAGACCATTGCAGAGATGAGGAAGCAGGACCTGGCTAAAGACACGGACCCACTCAAGCTGAAGGTGGGTGGGTGGGCAGCTCTTCCTGGGAGCCCAGAGGCCTCAACCCATGGCCCCTGGAGCATCTGCTGTGCCTTATGGAGCCGGCGTCTCCAGACAGCAACCTTTCACCCCTGGAGCATCTGCTGTACCACATGGAGCCGGCGTCTCCAGACAGGGACCTGTCACTGCCGATGGGCCTGGCAGCCCTCAAGGACAGGGTGGCCTGAGGCCAGGGGGGCAGGGCAGAGTCAGGCCCCAGGCTGTGCTGCTCCCCACGTGCCCAGATGGCTCAGCGCTGGTGGGGGTGGGGTGGGCGGGCGTTACAGGAGTGAGTGCCCCGGGGTGTTTGCAGAGACTGTTGAGGGCAGGCGTCTCTTGGGGGCTGCTCTGGGTACTGAGCCTCCCAACCCAGGACGCTCACTGGGGGGTGAAGAAGCAGCGGT	16	474	-1
T00612	None		ENST00000415806		chr5	118727074	105M1332N89M	Plus	ACTGGCATCTCTGGAGAGAACAGTTGCCACTCGACTCAGAGATTGAGTAGACACCCAAAGAACTGCAGTTCTTAAGCCTTAGGAGAAGCGAGAGAAATGGGCCAGTGGCCACAGATGTCTTTAATTCCAAAAACCTGGCCGTTCAGGCACAAAAGAAGATCTTGGGTAAAATGGTGTCCAAATCCATCGCCACC	16	164	-1
T00613	None		ENST00000513972		chr5	179047858	179M206N95M	Plus	GACCTCACTGCTCAGCAACAAACATGACTACATACCTGAGAAGAACTGAACAATTTCTTCCTTGCTACATCCAAAGGGAAGTCCTCTAAGCCGTACAAAGCCATCATTGGCCGTGTCAGGACTATTTGGACCAGTATGCTTCAACACCCAATCCATTTCAACGTTGTTTGACTTGAATACTTCAACATATCTGTGTCCCATAGTTTCTCTGTCTTTTTTCAGGGCCAATTTGACTTCATCTTCTGATTCAAGTTCAACAAAAGTGCCGCCACTT	16	244	-1
T00614	None		ENST00000530691		chr11	12229554	107M3656N102M1357N133M	Minus	CACACCCTGAATCTCTTCCACCTTGGCTTCCGCTGTGCTGTTTCTGTTTATGAAGTTGGCGGTGATGGCAATCGCCAGCTTCCCACGGAATTCTTTTCTTCTGAACCCTTCCAGGGTGTTCCTGCGGCCATCGGCACCAATGATGACGTCAAACTCAAACTCCGACAGAGAATGGTCTGTAGGGAGAAATTCTGCCCGCCAGCCAATTTTTTGATTTTCTTGATCTTCAGGAGGCTCTAGAACCTTCACGAACTCCACATTCACATGGATTTCAACTCCCAGCATCAGGGCCACCTTGAATAGGATGAGCTGTAGTTGGCGAATACCTGTCTGGCAGGAAGG	16	312	-1
T00615	None		ENST00000539361		chr11	61552141	401M	Minus	CTCACACCTGCAGCTAGGCCCACCCAGCACAGGGCCTGGGACAGATGGGGCCCCAATCAATATTTTCTGAGTAAACACATGAATGGGCAAGAAAAAATAATCACTACTTCCCTTCATTTGTCCTGAGCGTCTTCTCCCATGGCCTCTTAGGCTCAAGAAGAAACTGGGGGTCCATCAGCCCCAGGGACAGTCATAACTTCCGGTTACCTGGCCAGGGAGGAGCTCACCATCCAGTTCTCCCAGAAGAGGTGGCCAAACATGGAACCTGAGGGGCCCTCTGATGCTGTACATCTAGCTGTGCCACTTCCCCAACCTGAGCATGAGGTCGGCTCCTTCCTGCTTCTGCAGACACCTCCAGTGAGCCACAGCCCTCCCCGCCATGGGCTCCCAGACACCTGCAT	16	371	-1
T00616	None		ENST00000543845		chr12	9098925	69M310N77M	Minus	TGAGATTTGAGGCCTGTAGAGGCCAAAGAGGTTTCAGAAGACTACATCAAGCCATCAAACAGTAAAGAGGATGTTCCCTTTCTACAGCTGCTGGAGGACTGGACTGCTACTACTACTCCTGGCTGTGGCAGTGAGAGAATCCTGGC	16	116	-1
T00617	None		ENST00000543159		chr12	9098925	456M	Minus	TGAGATTTGAGGCCTGTAGAGGCCAAAGAGGTTTCAGAAGACTACATCAAGCCATCAAACAGTAAAGAGGCAAGGATGGCTCCACCCAAGCTGTCATCATTCTTTTTTAAGTTCTTTCATTTCCCTCTTCCCAACTTTGTAGTTTGTTCTGAAAGACTCACCTATACATTAGACTACAAGTTACATATAAATGAATTTTCTGCTGCAGATGCTCTTGTTACAGAGATATTAAAATGTACTATGTGTTGCATATGCCAGAGAATCTTGTACTTTCTGGATAATTAAAATACCATCGATTTATTACACATTCATACGCTTTATCTCTTTCCTCTCTCTCCTGATCCTACCTGCCCTCCCCAACACACACTCTCTCCCAAAGGATGTTCCCTTTCTACAGCTGCTGGAGGACTGGACTGCTACTACTACTCCTGGCTGTGGCAGTGAGAGAATCCTGGC	16	426	-2
T00618	None		ENST00000551073		chr15	42279179	85M673N395M	Minus	CTGACCCTGCTGGATGCCTGGAACCTGTCACACACCTCGGAGGAGTTTTTCCACAGGTGGACAAGGGAGAAAGTGCAGGACATCGAAGACGAGCCGATCCTGCCTGAAATCCCCAAATGTGATGCTAACATCCTGGAGACCACGGTAGTGATCCCAGGGTCATGGCTGTCCAATTCTTTCCGAGAAATCCTTACCCATCGGTCCTTCGTGTCTGAGTTTCACAACTTCCTGTCTGGGCTGCAGCTGCACACCAACTACCTCCAGAATGGCCAGTTCTCTAGGTGGAAAGGTAACCCTACCTGGCTACTCCTTGAGGCCTGCCTCCATATGGAGGAGGAAGATGTGGATGTCAAGGCTGCCATGGATAAAGAATAAGAAAACTTCTCTGGCTATGTTCACTGGGCCAGGCACCTCTCTCCCCATGGTGTTTTCCACATTTGGTGGTGTCGTCTTGAACACTGTATGTGTCTGGCAGGAAGG	16	450	-1
T00619	None		ENST00000500117		chr16	59098153	483M43176N3M	Minus	GACTGCCTGCCCCATAAACACAATAAATACTTTTCTATTATGAATACTTTTAAATACCTGTTGAACCCATTCTCCCTCCTTGTGATCATTAATTTTACATATCGACTTGCCTAAGCCTTTGAGTGCTGAGATATTTGGTCAAATATTACTGTGGATGTGTCTACGAGGGTGTTTCTGGATAAGATTAGATTTGAATTGGTAGACTGAGTAAAGCAGATTGGCCTCCCTAATGTGGCTGGGTCCCATCCAATTACTTTAAAACTTGCATAGAACAAAAAAGCTGCAAGATGTTAGGCTAGAACATTAGGCTTCTCCTGACCTCGGACTGGAATTTACACCATCAACTGTCCTGGTTCTCAGGCCTTCAGATTCAGACTGAAACTACATCACTGGTAATATGTGCAGCACCAGCTGTCTTGGGTGTCCAGCTTGCCGACTGTGAGTCTTGGGACTTGTCAGCCTCCATAATCATGTGAAGCAAATCGC	16	456	-1
T00620	None		ENST00000572999		chr16	3361672	238M	Plus	GCCAGTACACCTGTCGCTCTGCCTCCACCCCCACAAACCAAAAGTAAGTTCTGTGGTAACAAGGATGGGAATTATTTCTAGGTTGCAGTCCATGAGCTGGGAAAGGAGGCAGTGCTCTTGGGAGAAACAGCAGAGGCCTCAAGTTTCGGGCTGAAGCCAACAGAGTCCCAACCAGTGGGCGTATCCCAAGATGAAGAATTTTGGAATACATACGAGGGTCTGCAAGACTGGCTCAGCA	16	208	-1
T00621	None		ENST00000576119		chr16	20493667	241M	Minus	GACCTCACTGCTCAGTGGTTCCCATAATTTTCTGTATGATGTATTCTGTACGTACCAGAGGTATGATAGTGCCAGGCTTACACCCTGCGGGAATGTGCTAGGACACTGATCCACACATCCCACCTTAATATTTTCCTACACACACATCAAAGTCCACTAGACCCCATCTGAGCCTATTTCTATAAGCCTGGCTTTATAGGGGTCTTTCTTTTTCCCTTTATTTTCACTGTGAAATCTGTGG	16	211	-1
T00622	None		ENST00000570439		chr17	7250326	131M	Minus	CTCTGGACTTCAGCCACCACGTGCCCGACTCCCCCAGGCTCCCTTCCCCTGGCCATTCCACCAGAGCCCAGGGTGGCAGCAGAGCCTATGGCCAGGTGTCCTGAGCCCTGGGGGAGAGACGGGAAGAAAGG	16	101	-1
T00623	None		ENST00000593204		chr17	34956075	384M	Minus	GTCCTTGGGTGCTGAGGACGTAGATAACAGCCTCGGCCACATCCTCGGGTTTGAGACACTGAGAGCACCAGGGGAATGGGTTGAGACAAGGACAGAATGGACTCAAATTCCCTCCCACCACTGAGCTTCTCTGTGGCATCCACACATCCACCCCAACCCTCCAGGAGGAGCCACAAAGGCTGGAAGAGTGGAGTCTGAAGGCCGAGCTTCCCTCTGCCTTCATTTAGGGAGTCAGTGGCTTCACCAGGCTCAGAGGGAGGCCCCACCTTCATTTGCTCATAGGTGGCAGCTGCCTTCTCAGGGTCCTTGTCGTGGAGTTTGAAGGCGAATTGTGTCTCCACCACACCTGGAGAGATGCACTGGGCCAACAGAGAGGGCTTTCTC	16	354	-1
T00624	None		ENST00000583784		chr17	80006830	337M	Minus	GGTGTCCCCCAACTCAGCTCATGCCATGCTTCAATGCTGTTTCCAAGCCTGGCCTCCCCGAGGGCCTGGGGAGAGGGGGTGGGCAAAGGGGCTCTAGCAGGGCTCCTGGCCAGGGGCAGGCGTGGCCCGAGACCAGACCAGGCCACACACTCTGCCCACACCCTTCCCTCCCAGGTTACCTTGAGCCATGGGGGTCCTGAGAACCCACATAACGTGGTGAACGTGGCTGGAGGCTTCAGCCTGCATCAAGACCCCACACGGTGAGTAGGTAGTGGCATGGGCAGGCCCTCGGCCCCGCAGGGGCTCTGGCATCAGCTCCCTCTACCTGCTGCCCTGA	16	307	-1
T00625	None		ENST00000598360		chr19	4719870	142M2557N84M	Minus	CCCTCTGCAGCTCCTGAGTGGGGGAGGCTGAACGGCTGGCCGGTGCTTCCATTAACCTGCCACATTCATGACATGTTTATCCTATAAAGGTCTGTGTCCCACGCCTGCAGCTGGAATGGAGGCTCTCTGGACCCTTTAGAAGGCACCCCTGCCCTCCTGAGGTCAGCTGAGCGGTTAATGCGGAAGGTTAAGAAACTGCGCCTGGACAAGGAGAATACCGGAAGTG	16	196	-1
T00626	None		ENST00000491604		chr22	18907275	434M1543N37M	Minus	GCTACATGCAGGACTGTTTGTGTTTTGGTTTTAAATTTATTTAATTAATTTATTTTTTATAGAGACCAGGTCTCACCATGTTGCCCAGGCTGGTTTCAAACCCCTGGGCTCAAGTGACCTGCCCGCCGCAGCCCCCAAAGTGCTGGGATTATAAGTTTGAGCCCCCGCATGCCACTGGTTTTAAATTTTTAAACAGAAAACAATATTTATATTTCCTCTGTCTTTTAAAACTGAACACCGAGGTGGGTTTTGTGGTGGGTGGTGAACGGACAGGTTTGGGCCTCGATCCCCCACCCGACCCTAGCACCCACAGGTGGGGGTGCCCCCTCTGCTGATGCGCCTCCTCCCTCAGCACCATGGACCTGCTGGACTGGAGCAGCCTCATCGACAGCAGGACCAAGCTGTCCAAGCACTTGGTAGTCCCCAACGCACAGACAGGACAGCTGGAGCCCCTGCTGTACCGCTTCACTG	16	441	-1
T00627	None		ENST00000414347		chr22	37813885	80M945N74M	Minus	TGTTTGCGCAGCTGGAGACGAGGTTCCGCCGAGGCCCGTCTGTCTGGGAGCGCCTGTCTGCGCAGGTGGAGGTCAGCCAGAAGGAGAGGACTTGGGTGAGGAGCTGCTGCCACCCGGGCTGGGCCAGGACCTGAGATCTCATTGCTACTGCTGT	16	124	-1
T00628	GeneExpression	KIR2DL2	ENST00000344867	1,2	chr19_gl000209_random	21911	63M908N37M	Plus	CGCGGCCGCCTGTCTGCACAGACAGCACCATGTCGCTCATGGTCGTCAGCATGGCGTGTGTTGGGTTCTTCTTGCTGCAGGGGGCCTGGCCACATGAGGGAGTCCACAGAAAACCTTCCCTCCTGGCCCACCCAGGTCGCCTGGTGAAATCAG	27	100	1
T00629	GeneExpression	PECAM1	NM_000442	exon		-1		Plus	GGCCCCATTGTTCCCGGTTTCCAGCCATGGCTGCCATTACCTGACCAGCGCCACAGCCGGTCTCTCTGCAGGCGCCGGGAGAAGTGACCAGAGCAATTTCTGCTTTTCACAGGGCGGGTTTCTCAACGGTGACTTGTGGGCAGTGC	19	111	1
